This reference process map organizes CAR-T cell therapy manufacturing and quality control in the order cell collection → activation → gene transfer → culture and expansion → harvest and freezing → characterization. The best method depends on whether the product is autologous or allogeneic and on the gene transfer route (lentiviral, retroviral or non-viral), so each step also lists alternative and complementary methods.

Editor's note. Lentivirus is preferred over retrovirus because it can enter non-dividing cells and carries a relatively lower risk of insertional mutagenesis. When the starting material is living T cells, donor-to-donor variability is the real enemy. The first stumbling block in a tech transfer is usually not the process but the quality of the apheresis material. Differences in pretreatment and lymphocyte counts keep the cells from expanding, and the low yield gets mistaken for a culture problem. Absolute VCN quantification by ddPCR is less a regulatory requirement than a practical safety valve for catching early whether transduction is running out of control. Closed-system automation looks like a labor-cost story, but its real point is to remove contamination risk and operator dependence in a one-patient, one-batch process.

Made fromLentiviral vector that delivers the CAR gene into T cells (transduction material for the standard process), Plasmid DNA used as the source of the CAR transposon / transposase in non-viral manufacturing

At a glance

Select a step to jump to its card. ◇ marks a step whose standard method changes with the condition.

  1. Collection and selection4 steps
    1. Apheresis
    2. Mononuclear cell isolation and washing
    3. Freezing and cold chain
    4. T cell selection and enrichment
  2. Activation1 step
    1. T cell activation
  3. Gene transfer1 step
    1. CAR gene transfer (transduction) (changes with the condition)
  4. Cell culture and production1 step
    1. Expansion culture (changes with the condition)
  5. Harvest and clarification2 steps
    1. Washing and concentration
    2. Fill-finish / cryopreservation
  6. Quality attributes and analytics9 steps
    1. CAR expression rate
    2. VCN measurement (changes with the condition)
    3. Cell count and viability
    4. Immunophenotype and subset analysis
    5. Potency measurement
    6. RCL testing (changes with the condition)
    7. Sterility test
    8. Mycoplasma and endotoxin testing
    9. Control of process-related impurities

Collection and selection(4 steps)

Step 1: Apheresis

The quality of the starting material (T cell number, composition, fitness) largely decides the final product, so standardizing collection comes first.The quality of the starting material (T cell number, composition, fitness) largely decides the final product, so standardizing collection comes first.

Standard methodLeukapheresis (mononuclear cell collection) by continuous-flow centrifugationLeukapheresis (mononuclear cell collection) by continuous-flow centrifugation
ReagentsPriming and replacement with Terumo BCT ACD-A anticoagulant (sodium citrate / citric acid / dextrose) + normal saline (0.9% NaCl) from Baxter, Hexal, etc. Run at an anticoagulant ratio (AC:WB) of roughly 1:12–1:13.
Details and 3 alternatives

This step coversLeukapheresis (collection of starting material) (apheresis / starting material collection)

The starting point of CAR-T manufacturing. The patient's own blood runs through a device that skims off only the "mononuclear cells" containing the T cells used as raw material.

Blood flows through a continuous-flow centrifuge, which returns red cells and plasma to the body and continuously collects only the target cell layer. This gathers the required amount while keeping the burden on the patient low.

The number and vigor of the T cells collected here largely decide how good the final product will be. That is why this foundational step is the one where standardization matters most.

Mononuclear cells, including the T cells that are the raw material for CAR-T, are collected from the patient's own blood. The quality of the starting material (T cell number, composition and fitness) largely determines whether the final product succeeds, so standardizing this step is the top priority.

MakersTerumo BCT, Fresenius Kabi

Why it is the standard. Spectra Optia is the de facto standard instrument for mononuclear cell collection in cell therapy and transplantation. Automated interface management gives high reproducibility, and it is widely used to collect starting material for CAR-T manufacturing. It is also common under the collection-site requirements for commercial CAR-T products (Kymriah, Yescarta, etc.).

Alternatives in practice

  • Intermittent-flow centrifugal apheresis · Terumo BCT COBE Spectra (older-generation mononuclear cell collection by two-stage chamber separation) — For sites still running legacy equipment. Replacement with the Spectra Optia successor is under way, and new installations are not recommended.
  • Intermittent-flow apheresis · Fresenius Kabi Amicus Separator (MNC collection function) / Haemonetics MCS+ — Widely used in transfusion departments. Choose to match the site's existing platform.
  • Downstream separation from a whole blood draw (research / small scale) · Whole blood bag collection + the density gradient separation device from [1] (Sepax C-Pro, etc.) — For research use with patients who cannot undergo apheresis or with small samples. Not suitable for clinical production scale.

Step guide

What you actually do

  1. Draw blood from the patient's vein into the dedicated kit of the collection device (a single-use flow path set) and mix in anticoagulant (ACD-A) at the set ratio to prevent clotting
  2. Separate the blood into layers of plasma, mononuclear cells, red blood cells and so on by continuous-flow centrifugation (a method that separates into layers by centrifugation while flowing)
  3. An optical sensor reads the position of the mononuclear cell layer (buffy coat) and sends only that layer to the collection bag, returning the rest to the patient
  4. Record the volume of blood processed (e.g. 10 to 15 L) and the contents of the collection bag together with the patient identifier
  5. Close the bag and ship it to the manufacturing site, either fresh or frozen

Equipment and materials

Decision points

What decides the collection device and the collection program?
There are continuous-flow and intermittent-flow types, and whether the chamber is single-stage or two-stage also changes the amount of platelets and monocytes that end up in the product. Collection efficiency figures (CE2, the proportion of cells collected out of the blood processed) cannot be compared unless donor mobilization, processed blood volume and program are the same, so where the site already has a device, asking about its track record on that device is also a choice.
What decides the volume of blood to process and the timing of collection?
Estimate the processed blood volume needed and the yield you can expect from the patient's absolute lymphocyte count (ALC) and the history of prior treatment. For patients with a low ALC the processed blood volume is sometimes increased (e.g. 12 to 15 L), but even then the target yield (e.g. 1.0 × 10⁹ or more CD3-positive T cells) may not be reached. Whether to bring collection forward, or split it over several sessions, is discussed between the collection site and the manufacturing site in advance.
Where do you draw the acceptance criteria?
In autologous manufacturing there is no substitute for the patient, so criteria that are too tight mean mechanically rejecting material that cannot be replaced, while loose criteria mean more manufacturing failures. Where to draw the line on cell number, viability and T cell proportion is set by risk assessment and written into the procedure, and decisions when material falls outside the criteria follow the approved procedures and the quality unit.
Where is the boundary of responsibility between the collection site and the manufacturing site?
Write into the quality agreement who assigns the identifier, who checks it on receipt, and which side keeps the handover records. Where the boundary is vague, periods appear in which nobody is watching (waiting at an airport, storage over a holiday), and if the temperature goes out of range during that time, it is the receiving side that notices.

Common mistakes

  • Comparing devices on collection efficiency figures alone, and overlooking how platelets and monocytes come along
  • Setting the collection day at a time when the patient's ALC is low, and going on to manufacturing without reaching the target yield
  • Ownership of the records is not settled between the collection site and the manufacturing site, leaving a gap in the temperature record during shipping

Check at your own site

  • Are your acceptance criteria set looking not only at cell number but also at how monocytes and platelets come along?
  • Each time your collection bag changes hands, who checks the identifier, and against what?

Step 2: Mononuclear cell isolation and washing

Removing platelets, red cells and residual DMSO improves T cell activation and transduction efficiency and their reproducibilityRemoving platelets, red cells and residual DMSO improves T cell activation and transduction efficiency and their reproducibility

Standard methodFicoll density gradient centrifugation in a closed, automated cell processing system to isolate mononuclear cells, followed by removal of platelets and red cells, washing and concentrationFicoll density gradient centrifugation in a closed, automated cell processing system to isolate mononuclear cells, followed by removal of platelets and red cells, washing and concentration
Details and 2 alternatives

This step coversMononuclear cell isolation and debulking wash of the starting material — mononuclear cells (PBMC) are isolated from the apheresis product by density gradient centrifugation or similar, and platelets, red cells and plasma/cryoprotectant are removed while the cells are concentrated (for frozen material, this follows thawing) (mononuclear cell isolation and washing)

The "prep work" that removes the bystanders in the collected blood that get in the way of proliferation. This pretreatment step concentrates only the mononuclear cells.

Centrifugation that exploits density differences, or washing, separates platelets, red cells and plasma. For frozen material, the DMSO in the cryoprotectant is also washed out after thawing.

These contaminants cause T cell aggregation and suppress proliferation. Removing them first keeps the selection and activation that follow consistent.

The apheresis product contains platelets, red cells and monocytes, which cause T cell aggregation, suppress proliferation, lower transduction efficiency and interfere with in-process testing. Isolating and debulking the mononuclear cells by closed-system density gradient centrifugation or by washing and concentration, and, for frozen material, washing out the cryoprotectant (DMSO) after thawing, is standard pretreatment before the subsequent selection and activation.

MakersCytiva, Baxter, Grifols/CSL Behring

Why it is the standard. Sepax C-Pro is closed and automated, which limits lot-to-lot variability, and a single unit can perform mononuclear cell isolation, platelet/red cell removal and wash-concentration while maintaining sterility. It is therefore widely used for debulking pretreatment of CAR-T starting material.

Alternatives in practice

  • Counterflow centrifugal elutriation · Terumo BCT Elutra Cell Separation System (size separation by elutriation) — Removes platelets and monocytes by fractionation without Ficoll. Closed system, well suited to large volumes.
  • Spinning-membrane / filtration-based automated wash and concentration · Fresenius Kabi LOVO (handled by Cytiva; spinning-membrane filtration with a 4 µm track-etched membrane) / Cytiva Sefia — A simple route that skips density gradient separation and only washes, concentrates and removes platelets.

Step guide

What you actually do

  1. Connect the product bag to the single-use kit of a closed, automated cell processing system without opening it, using a tube welder or the like
  2. Layer the product over density gradient medium (Ficoll or the like) and centrifuge it, separating the mononuclear cell layer by the difference in density. Platelets and red blood cells are removed
  3. Wash the mononuclear cells with wash solution, replacing plasma and anticoagulant, and concentrate them to a volume that suits the next step
  4. For frozen material, wash the DMSO (cryoprotectant) out of the thawed product
  5. Measure the volume, cell number and viability of the processed product and record the recovery

Decision points

Separate on a density gradient, or do only washing and concentration without one?
Where you want to reduce platelets, red blood cells and granulocytes firmly, a density gradient is a candidate. Elutriation (separating cells by size and density in counter-flow centrifugation) can fractionate platelets and monocytes without Ficoll, and spinning membrane filtration (keeping cells inside a rotating membrane and passing only liquid out) is a simpler route that omits the density gradient, centred on washing, concentration and platelet removal. Decide by the cell types you want to remove and by whether a magnetic selection step follows.
What decides the number of washes and the wash solution?
For each substance you want to remove (plasma, anticoagulant, DMSO), measure the residual amount and set the number of washes needed. More washes leave less residue, but add centrifugation and resuspension cycles, which load the cells and lower recovery. The wash solution is often an isotonic electrolyte solution, or one with human serum albumin added, and albumin is controlled as a raw material for its origin and qualification.
A closed, automated system, or manual centrifugation including open operations?
A closed, automated system has the advantage in sterility and reproducibility and may allow a lower cleanliness requirement for the facility, but that presumes agreement with the authorities and support for the aseptic operation. Manual centrifugation needs lighter equipment, but adds open operations in a safety cabinet and lets operator-to-operator differences in.

Common mistakes

  • Trying to reduce residues by increasing the number of washes, and overlooking the cumulative load on the cells and the drop in recovery
  • With frozen material, the time from thawing to removal of DMSO stretches out and viability falls
  • No procedure is set for splitting a product that exceeds the processing capacity of the system

Check at your own site

  • For the cells you want to remove from your product, which measurement do you use to confirm how far they have been reduced?
  • Is your number of washes the number set by measuring the residual amount of each substance you want to remove?

Step 3: Freezing and cold chain

Decouples collection from manufacturing in time, absorbing shipping delays and slot scheduling for a stable supplyDecouples collection from manufacturing in time, absorbing shipping delays and slot scheduling for a stable supply

Standard methodDMSO-containing cryoprotectantDMSO-containing cryoprotectant
Details and 2 alternatives

This step coversCryopreservation and shipping hold of the starting material (apheresis product) — at the collection site the leukapheresis product is frozen at a controlled rate in a DMSO-containing solution, then stored frozen and shipped through the cold chain until its manufacturing slot (freezing and cold chain)

The "time buffer" between collection and manufacturing. The collected material is frozen, stored and shipped, and waits until its turn in manufacturing comes.

At the collection site, the material is frozen slowly at a constant rate together with a DMSO-containing protective solution. It travels through the cold chain and stays frozen until a manufacturing slot opens.

International shipping delays and slot waits are absorbed here. Frozen starting material has been shown to have quality equivalent to fresh material.

For commercial CAR-T, in both centralized and decentralized manufacturing, controlled-rate freezing and a frozen hold of the apheresis starting material have become standard to absorb international shipping delays from the collection site to the manufacturing site and waits for manufacturing slots. Multicenter studies have confirmed that frozen starting material often shows viability, expansion, CAR-positive rate and cytotoxicity equivalent to fresh material.

MakersThermo Fisher Scientific, BioLife Solutions, Charter Medical, Grifols/CSL Behring

Why it is the standard. Controlled-rate freezing minimizes ice crystal formation and osmotic stress, giving post-thaw viability of ≥90% and downstream manufacturing performance equivalent to fresh material. CS10 is serum-free and GMP-ready, and it is widely used to freeze cell therapy starting material.

Check also. Many reports show frozen starting material with viability and expansion capacity equivalent to fresh material, but post-thaw recovery can vary with the donor, the disease and prior treatment. When the site, kit or freezing rate changes, it is safest to measure equivalence with your own material before using it in production.

Alternatives in practice

  • Fresh shipping without freezing · Validated 2–8 °C shipping container (e.g., temperature-controlled containers such as Pelican BioThermal Credo / Cytiva) — Skips freezing for short distances and immediate manufacturing. Time constraints are tight.
  • LN2-free conduction-cooled controlled-rate freezing · Cytiva VIA Freeze (conduction-cooled CRF, no liquid nitrogen needed) — For sites without LN2 supply infrastructure and for decentralized manufacturing.

Step 4: T cell selection and enrichment

Removes monocytes, granulocytes and red cells and enriches T cells, stabilizing the efficiency of the activation and gene transfer that follow.Removes monocytes, granulocytes and red cells and enriches T cells, stabilizing the efficiency of the activation and gene transfer that follow.

Standard methodPositive selection with magnetic beads (CD4/CD8 or CD3 selection)Positive selection with magnetic beads (CD4/CD8 or CD3 selection)
Details and 3 alternatives

This step coversT cell isolation and selection (enrichment) (T cell selection and enrichment)

The step that "picks out" only the T cells, the main players, from the mixture. Magnetic beads select the cells that carry the marker.

Positive selection with magnetic beads, using CD3 on the T cell surface (and CD4/CD8 as needed) as the marker. Monocytes, granulocytes, red cells and others are left behind.

Higher T cell purity stabilizes the efficiency of the later activation and gene transfer. This final selection evens out the quality of the starting cells.

The collected material contains monocytes, granulocytes, red cells and other cells. Removing them and enriching T cells (CD3, and CD4/CD8 as needed) stabilizes the efficiency of activation and gene transfer.

MakersMiltenyi Biotec

Why it is the standard. The CliniMACS family is the standard platform for clinical T cell selection under closed-system GMP. Prodigy integrates selection through culture and harvest, and it has an extensive track record in decentralized and hospital-based manufacturing.

Alternatives in practice

  • Counterflow centrifugal elutriation · Terumo BCT Elutra (label-free separation by density and size) — Uses no antibody beads, avoiding their cost and residual-bead concerns. Purity is somewhat lower.
  • Skip selection and activate PBMC directly · (No equipment needed) Add the activation reagent from [4] directly — Shortens the process. Variability in the cell composition of the final product increases.
  • Naive/memory T subset selection · Miltenyi CliniMACS CD62L GMP MicroBeads / CD45RA depletion — A next-gen design that enriches Tscm/Tcm to improve persistence.

Step guide

What you actually do

  1. Add antibody-coated magnetic beads (microbeads) that bind CD4 and CD8 (or CD3) to the washed mononuclear cells and mix
  2. In a closed magnetic cell separation system, pass the cells through a column in a magnetic field and hold the bead-bound cells on the column
  3. Remove the magnetic field to elute the positive cells and collect the selected cells in a collection bag
  4. Measure cell number, viability and purity, and pass the cells to activation

Decision points

Select, or activate the mononuclear cells as they are?
Omitting selection shortens the process but increases variability in the cell composition of the final product. Selection reduces monocytes and the like, which tends to make activation and gene transfer more stable. The greater the variability in the composition of the starting material, the more value selection has.
Is the target of selection CD3, CD4 and CD8, or memory cells?
It depends on how far you want to specify the composition of the final product. There are designs that select CD4 and CD8 separately and mix them at a set ratio, designs that select on CD3 as a whole, and designs that enrich memory subsets (CD62L and the like) to aim for persistence in the body. If you want the ratio fixed, select separately; if you take simplicity of the process, CD3 is a candidate.
Selection with magnetic beads, or separation without beads?
Bead-free separation such as elutriation avoids reagent cost and concerns about residual beads, but purity is often a little lower than with the magnetic bead method. The magnetic bead method has more of a track record in closed GMP operation, and an integrated system can carry on into culture.

Common mistakes

  • Looking at purity alone and falling below the cell number needed because recovery has dropped
  • The number of cells processed has changed, yet the reagent amount is left as it was
  • Not confirming whether the reagent used for selection can remain in the final product, and so not including it in the residual impurity testing

Check at your own site

  • Is your selection there to set the CD4 to CD8 ratio of the final product? Or to hold down variability in the starting material?
  • Do the purity and recovery of your selection come out the same for lots whose starting material has a low cell number?

Activation(1 step)

Step 5: T cell activation

Activates resting T cells with CD3/CD28 to start division, greatly raising viral vector transduction efficiency.Activates resting T cells with CD3/CD28 to start division, greatly raising viral vector transduction efficiency.

Standard methodActivation with a soluble CD3/CD28 agonist reagentActivation with a soluble CD3/CD28 agonist reagent
Details and 3 alternatives

This step coversT cell activation (starting proliferation) (activation)

The "start switch for proliferation" that wakes up dormant T cells. In the resting state, neither division nor gene transfer makes progress.

When a reagent delivers the 2 activation signals, CD3 and CD28, at the same time, the T cells wake up and start dividing.

Awakened cells accept the virus more readily, so the efficiency of the subsequent CAR gene transfer rises sharply. This move decides how well the later steps work.

Resting T cells do not divide and are hard to transduce. Activating them with CD3/CD28 signals starts proliferation and greatly raises the efficiency of retroviral/lentiviral gene transfer.

MakersMiltenyi Biotec

Why it is the standard. TransAct is soluble and needs no downstream magnetic removal. It is integrated into the CliniMACS Prodigy workflow and is the standard for closed, automated manufacturing. It is used in several commercial and clinical processes.

Alternatives in practice

  • Activation with paramagnetic beads · Thermo Fisher CTS Dynabeads CD3/CD28 (4.5 µm magnetic beads, product number 40203D) — Well established, but the beads must be removed with a magnetic stand after culture [7].
  • Soluble nano-reagents / reversible multimers · Juno/Bristol Myers Squibb-type Expamer (Streptamer-type reversible MHC/antibody multimers) / Cloudz (R&D/Bio-Techne dissolvable hydrogel) — Aims for zero residual beads. Platform dependent.
  • Artificial antigen-presenting cells (aAPC) · K562-based aAPC feeder cells (4-1BBL/CD64-expressing lines, custom-built by each company) — Strong co-stimulation is obtained, but feeder-derived impurities must be controlled.

Step guide

What you actually do

  1. Put the selected T cells into medium at the set density together with the activation reagent (a soluble nanomatrix or magnetic beads carrying anti-CD3 and anti-CD28)
  2. Add cytokines (IL-2, or IL-7 and IL-15) and culture at the set temperature and gas conditions
  3. Look at cell size, surface markers and the start of proliferation to confirm that activation has taken, and set the timing of gene transfer
  4. Where beads are used, record the amount and the lot of beads added, on the premise that they will be removed later

Equipment and materials

Decision points

Magnetic beads, or a soluble nanomatrix, as the activation reagent?
Magnetic beads have more of a track record, but a step is needed to remove the beads magnetically after culture, and residual beads fall under the specification. A soluble nanomatrix needs no washing or removal and is easy to build into a closed, automated system. Where you do not want to add a removal step, soluble is a candidate; there are also approaches using reversibly removable multimers or artificial antigen presenting cells (feeder cells), but these add dependence on the platform and control of impurities from the feeder cells.
Which cytokines do you use, and at what concentration?
IL-2 strongly supports proliferation, but tends to push the cells towards the effector (terminally differentiated) direction. Where you want to keep young memory cells, combinations with IL-7 and IL-15 are considered. Set the concentration by varying it with your own cells for each product, and control recombinant GMP-grade material by specifications for potency and purity.
How strong and how long a stimulus?
A strong, long stimulus gains cell numbers, but differentiation and exhaustion advance and potency and persistence in the body fall. Set the time from activation to transfer in the trade-off between transfer efficiency and keeping a young phenotype.

Common mistakes

  • Making the stimulus strong and long to gain numbers, so that differentiation and exhaustion advance and persistence is lost
  • Leaving the amount of activation reagent as it was even for a lot whose seeding density has changed
  • The lot of medium or cytokine has been changed, yet equivalence of proliferation and phenotype is not examined

Check at your own site

  • Were your activation conditions set looking not only at the numbers gained but also at the proportion of memory cells?
  • Is your specification for residual beads tied to the amount added at the time of activation?

Gene transfer(1 step)

Step 6: CAR gene transfer (transduction)◇ Branches

The core step that integrates the CAR gene recognizing a cancer antigen into the genome. Transduction efficiency and copy number determine dose and safety.Nucleic acids are introduced directly by electroporation, without a viral vector

Standard methodTransduction with a lentiviral vectorTransposon insertion by co-electroporation of minicircle DNA (CAR transposon) and Sleeping Beauty 100X (SB100X) transposase mRNA
EquipmentAutomated cell cultureGMP-compliant flow electroporation system (MaxCyte ExPERT GTx, etc.)
ReagentsLentiviral viral vector CDMOTransduction enhancerCAR transposon minicircle DNA, SB100X transposase mRNA (in vitro transcribed), dedicated electroporation buffer
With Non-viral (Sleeping Beauty transposon / electroporation)Transposon insertion by co-electroporation of minicircle DNA (CAR transposon) and Sleeping Beauty 100X (SB100X) transposase mRNAWith Lentiviral vector (viral transduction)Transduction with a lentiviral vector
Details and 3 alternatives

The heart of CAR-T. This step writes the CAR gene, the "eyes" that find cancer cells, into the blueprint (genome) of the T cell.

Cells are infected with lentivirus carrying the CAR gene, and the gene is integrated into the genome. The cell then becomes a soldier that can strike its target precisely.

The keys are the transduction efficiency and the number of copies that enter 1 cell. These tie directly to later dose design and safety control.

The CAR gene that recognizes a cancer antigen is integrated into the T cell genome. This is the core step of CAR-T, and the transduction efficiency and the copy number per 1 cell are directly tied to dose and safety.

MakersTakara Bio, Miltenyi Biotec, Lonza, Charles River

Why it is the standard. Lentivirus can transduce both dividing and non-dividing cells and is considered to carry a lower insertional mutagenesis risk than gamma-retrovirus, and it is used in Kymriah and others. Integration with the closed Prodigy system secures sterility and reproducibility.

Check also. Lentivirus is the standard but not the only answer. Switching to a non-viral approach (a transposon or site-specific knock-in, for example) changes the design not only of this step but also of whether downstream copy number quantification and replication-competent virus testing are needed. Choose the gene transfer method together with the regulatory and analytical set for the whole process, not for the step alone.

With Non-viral (Sleeping Beauty transposon / electroporation). The lentiviral vector drug substance, packaging cells and titer assays are no longer needed, but GMP manufacture of the minicircle/mRNA and optimization of electroporation conditions (voltage, cell concentration) become the new rate-limiting steps

Alternatives in practice

  • Gamma-retroviral vector transduction · RetroNectin (Takara Bio, recombinant fibronectin CH-296)-coated vessel + GMP retroviral vector — Kymriah uses lentivirus; Yescarta/Tecartus use gamma-retrovirus. Depends on dividing cells.
  • Transposon (non-viral) gene transfer · Sleeping Beauty (piggyBac, etc.) transposon systems + MaxCyte GT/ExPERT electroporation — Avoids the cost of viral vector manufacturing. Delivery efficiency and copy number control take some engineering.
  • Site-specific knock-in by CRISPR · MaxCyte ExPERT GTx / Lonza 4D-Nucleofector + AAV6 donor (TRAC locus, etc.) — Uniform expression and simultaneous gene disruption. For allogeneic/next-gen designs.

Step guide

What you actually do

  1. To T cells a set time after activation, add GMP-grade lentiviral vector (viral particles that carry the CAR gene and are designed not to replicate) at the set multiplicity of infection (MOI, the amount of vector added per 1 cell)
  2. Add a transduction enhancer where needed, and culture with the vector in contact with the cells
  3. After a set time, dilute or exchange the vector-containing liquid with medium to reduce the remaining vector
  4. Take a small sample early after transduction to confirm viability and the first appearance of CAR

What changes with the conditionWhether it is a viral vector (lenti, gamma-retro) or non-viral (electroporation of minicircle DNA with Sleeping Beauty transposase mRNA and the like) (with the viral route the manufacture and supply of vector becomes rate-limiting, and RCL testing and VCN control come with it. The non-viral route needs no vector manufacture, but control centres instead on transfer conditions such as voltage and cell concentration, GMP manufacture of the nucleic acids, and the drop in viability right after transfer. Neither can be set as the standard; choose by what you want to control)

Decision points

A viral vector, or non-viral (electroporation, transposon)?
Viral vectors give stable expression and are used in most approved products, but vector manufacture readily becomes the rate-limiting factor for supply and cost, and RCL testing (ruling out replication-competent virus) and control of VCN (copies per cell) come with it. Non-viral saves vector manufacture, but the challenges are optimizing transfer conditions such as voltage and cell concentration, GMP manufacture of the nucleic acids, and the drop in viability right after transfer. The choice is not which is better, but what you want to control.
Lentivirus, or gamma-retrovirus?
Lentivirus enters non-dividing cells as well, and designs such as the self-inactivating (SIN) structure make it easier to lower the risk of insertional mutation; gamma-retrovirus only enters dividing cells. There are approved products using each. How far your design proliferates the cells during activation decides whether you need the freedom lentivirus gives.
How do you set the amount of vector and the copy number?
The higher the copy number, the more expression tends to rise, but the number of insertion sites rises too. Aim for the minimum that gives the potency needed, setting it with MOI, VCN and CAR-positive rate side by side. A transduction enhancer works to raise copy number, so if you use one, plan to confirm its residues as well.
Do you make the vector in house, or use contract manufacturing (a CDMO)?
CDMOs differ in strength by scale and by the time it takes them to reach GMP. Choose looking not only at titer figures but at the detection sensitivity of RCL testing and at the lot documentation.

Common mistakes

  • Choosing the supplier on vector titer figures alone, without looking at the detection sensitivity of RCL testing or the lot documentation
  • Raising copy number to gain expression, so the number of insertion sites rises and VCN approaches the specification
  • Setting electroporation conditions in a small bench-top container and not re-confirming the uniformity of the electric field and of heating when the scale is increased

Check at your own site

  • Was the amount of vector (MOI) at your site set from the CAR-positive rate needed? Or from the amount of vector you had on hand?
  • Is your incoming testing of vector based on physical titer or functional titer, and by which method is it confirmed?

Cell culture and production(1 step)

Step 7: Expansion culture◇ Branches

The quality goal is to expand to the therapeutic cell number while avoiding exhaustion and keeping a young memory phenotype that favors engraftment and persistence.Cells need a recovery period right after electroporation, so the culture format tends to change

Standard methodPerfusion/agitation culture in a closed, automated bioreactorRecovery and expansion in static, gas-permeable culture after electroporation (static culture that does not rely on perfusion/agitation is often chosen)
EquipmentAutomated cell cultureGas-permeable static culture vessel (G-Rex, etc.)
With Non-viral (Sleeping Beauty transposon / electroporation)Recovery and expansion in static, gas-permeable culture after electroporation (static culture that does not rely on perfusion/agitation is often chosen)With Lentiviral vector (viral transduction)Perfusion/agitation culture in a closed, automated bioreactor
Details and 3 alternatives

This step coversCell expansion (proliferation) (expansion culture)

The step that expands the engineered T cells to "enough for treatment". They are cultured in large numbers cleanly in a closed, automated bioreactor.

Cells grow while nutrients and oxygen are maintained by perfusion (continuously flowing in fresh medium) or agitation. The device manages the conditions automatically and keeps manual handling to a minimum.

Simply increasing the number is not the goal. The quality goal is to avoid exhausting the cells by over-expanding them and to keep the "young" properties that favor engraftment.

Cells are expanded to the number required for therapy. At the same time, the quality goal is to avoid exhausting the cells through excessive proliferation and to keep a young memory phenotype that favors engraftment and persistence.

MakersMiltenyi Biotec, Thermo Fisher

Why it is the standard. Prodigy completes selection, culture and harvest on 1 closed-system instrument, which minimizes operator intervention and contamination risk. It is widely adopted for decentralized and in-hospital manufacturing, and reproducibility data are abundant.

Check also. Increasing cell number and preserving quality can be at odds. The longer the culture, the easier it is to reach the target number, but exhaustion progresses and the memory phenotype declines, to the detriment of engraftment and persistence. Decide the upper limit of the culture period by looking at the phenotype (#12), not only the final yield.

With Non-viral (Sleeping Beauty transposon / electroporation). Culture duration and seeding density must be adjusted to allow for the transient drop in viability caused by electroporation

Alternatives in practice

  • Static/semi-automated culture in gas-permeable vessels · Wilson Wolf G-Rex (gas-permeable silicone membrane flasks, 100 mL–5 L) — Low cost and low shear stress. Closed-system automation has to be added separately.
  • Fully automated cartridge-based manufacturing · Lonza Cocoon Platform (single-use cassette) / Cytiva Sefia + Xuri — For decentralized and point-of-care manufacturing.
  • Short-term culture / no culture (next-gen) · Miltenyi Prodigy shortened protocol (T cell culture shortened to a few days) / in vivo CAR systems — Advanced approaches that aim at Tscm enrichment and a shorter manufacturing time.

Step guide

What you actually do

  1. Put the transduced cells at the set density into the culture chamber of a closed, automated culture system, or into a gas-permeable culture bag or static container
  2. Add serum-free medium and cytokines (IL-2, IL-7, IL-15), and exchange or dilute the medium (feeding) on the set schedule
  3. Take a small sample daily or every other day to measure cell number, viability and metabolites (glucose, lactate), and follow how the cells are growing
  4. As the target cell number comes close, set the time of harvest. Do not expand them too far and exhaust them

What changes with the conditionA closed, automated culture system (perfusion, agitated) or static culture in a gas-permeable container (after lentiviral transduction an automated system, and for recovery after non-viral transfer (electroporation) a static container, tends to be chosen. With electroporation, seeding density and the number of days are adjusted to allow for the transient drop in viability. Neither can be set as the standard)

Decision points

An automated culture system, or static culture in a gas-permeable container?
An integrated automated system does the feeding and washing itself, so operator intervention and contamination risk are lower, but the chamber capacity becomes the upper limit on dose, and supply of the dedicated consumables tends to be tied to a single company. A gas-permeable static container costs less and gives less shear, but keeping sterility at the connections for feeding and sampling needs separate arrangements. For recovery of electroporated cells, static culture tends to be chosen.
What decides the number of culture days and the time of harvest?
The longer the culture, the more the cells differentiate and become exhausted, and potency and persistence fall. Harvest within the set range, looking at the cell number reached, the number of CAR-positive viable cells, the proportion of memory cells and so on. Whether the days can be extended when numbers fall short is confirmed with the quality unit, as a question of whether it is within the approved conditions.
Feeding on a fixed schedule, or coupled to glucose and lactate?
Because growth differs from patient to patient, a fixed schedule produces lots where the nutrients run out or where the culture is diluted too far. For a method that adjusts by looking at metabolites, the deciding point is whether it can be built into the recipe of the automated system.

Common mistakes

  • Extending the culture to make up numbers that fall short, and making a product out of exhausted cells
  • Drawing off too much culture liquid in sampling, so the cell number and volume fall short later on
  • Not looking at how growth differs from patient to patient, keeping the fixed feeding schedule, and releasing a lot whose nutrients ran out

Check at your own site

  • Is your harvest day set on cell number alone? Do you also look at the proportion of memory cells and at exhaustion markers?
  • Does your system stay within its maximum volume even at the dose for a heavy patient?

Harvest and clarification(2 steps)

Step 8: Washing and concentration

Removes magnetic beads and residual medium and cytokines, and adjusts the cell concentration before formulation to protect recovery and final quality.Removes magnetic beads and residual medium and cytokines, and adjusts the cell concentration before formulation to protect recovery and final quality.

Standard methodAutomated washing and concentration (and magnetic bead removal)Automated washing and concentration (and magnetic bead removal)
Details and 3 alternatives

This step coversRemoval of residual beads and contaminants, washing and concentration (washing and concentration / bead removal)

The "rinse" before formulation. This step washes away the reagents and residues used in culture and brings the cells to just the right concentration.

Cells are washed and concentrated in an automated device, and if they were activated with beads, the magnetic beads are also captured and removed. Nothing unnecessary is left behind.

Cleaning out the medium, cytokines and residues protects recovery and final quality. It is a cleanup step on the way to the finished product.

When beads were used for activation, the magnetic beads are removed and the medium, cytokines and residues are washed away. Adjusting the cells to an appropriate concentration before formulation protects recovery and final quality.

MakersCytiva, Terumo BCT, Fresenius Kabi, Miltenyi Biotec, Thermo Fisher

Why it is the standard. Automated washing and concentration in a closed system is the standard approach for raising recovery while maintaining sterility. Prodigy can complete the work within the same closed system, and LOVO/Sefia are widely used as dedicated machines for large-volume processing.

Alternatives in practice

  • Washing by counterflow centrifugal elutriation · Terumo BCT Elutra — Size-based separation also removes dead cells, debris and platelets at the same time.
  • Bead removal with a magnetic stand · Thermo Fisher CTS DynaMag (clinical magnetic stand) — Brings residual beads within specification in processes that use Dynabeads.
  • Washing and concentration by membrane separation · Fresenius Kabi LOVO (spinning membrane) — High recovery; processes large volumes in a short time.

Step guide

What you actually do

  1. Connect the harvested cell suspension to the single-use kit of a closed washing and concentration system without opening it, using a tube welder or the like
  2. Where activation used magnetic beads, use a magnet to remove the beads from the cell suspension
  3. Replace the medium and cytokines with wash solution by counter-flow centrifugation (a method that balances flow against centrifugal force and washes the cells while they stay suspended) or by spinning membrane filtration
  4. Concentrate to the concentration the formulation needs, and measure cell number, viability and recovery

Decision points

Counter-flow centrifugation, spinning membrane filtration, or manual batch centrifugation?
Counter-flow centrifugation does not pack the cells into a pellet but washes them while they stay suspended, so shear is held down. Spinning membrane filtration uses no centrifugal force and can aim at high recovery in a compact footprint. Manual batch centrifugation needs lighter equipment but adds open operations and operator-to-operator differences, so narrow the choice by how weak the cells are against shear and changes in osmolality, and by the volume handled (a few hundred mL for autologous).
What decides the number of washes?
It follows from the nature of the substance you want to remove. Medium components and small molecules such as DMSO are reduced by washing, but things that stick to the cell surface, such as residual viral vector, can be hard to remove however many washes you add. Measure the residual amount to set the number of washes needed, and weigh that against the load the extra washes put on the cells.
Is removal of the magnetic beads done on a magnetic stand or inside the system?
Where beads were used for activation, removal and confirmation of the residual bead count are needed. Using a soluble activation reagent removes the need for the removal step itself, replacing it with assessment of residual reagent.

Common mistakes

  • Setting the number of washes uniformly, so that substances hard to wash off, such as vector residues stuck to the cell surface, remain
  • Concentrating too far so the cells clump, and the concentration and volume no longer match at formulation
  • Having removed the magnetic beads, no method is set for counting the residual beads

Check at your own site

  • Is your number of washes the number set by measuring the residual amount of each substance you want to remove?
  • By which method is the residual bead count of your final product counted, and where was the specification drawn from?

Step 9: Fill-finish / cryopreservation

Freezes cells to allow shipment to the administration site and time before administration, while keeping post-thaw viability and function.Freezes cells to allow shipment to the administration site and time before administration, while keeping post-thaw viability and function.

Standard methodControlled-rate freezing with a DMSO-containing cryoprotectantControlled-rate freezing with a DMSO-containing cryoprotectant
Details and 3 alternatives

This step coversFormulation, filling and cryopreservation (fill-finish / cryopreservation)

The step that puts the finished cells into product form and freezes them into a "deliverable state". It is storage to buy time before the cells reach the administration site.

Cells are frozen at a slow, constant rate together with a DMSO-containing protective solution, then filled. This secures a margin for transport and administration.

Freezing stress damages cells. Protecting them with a protective solution and a controlled rate is meant to keep post-thaw viability and function.

Cells are frozen so that they can be shipped to the administration site and the time until administration is secured. The aim is to protect the cells from freezing stress and keep post-thaw viability and function.

MakersCytiva, BioLife Solutions, Thermo Fisher, Charter Medical

Why it is the standard. CryoStor CS10 is the de facto cryoprotectant for cell therapy and is also used in commercial CAR-T. Controlled freezing at about -1 °C/min in a CRF limits ice-crystal damage and secures post-thaw viability and function.

Check also. Freezing is the standard way to buy time until administration, but post-thaw viability and function depend on both the freezing conditions and the thawing procedure. Unless validation includes the thawing protocol at the administration site, a product that meets specifications at release may have diminished by the time it is administered. Some products are administered fresh (not frozen).

Alternatives in practice

  • General-purpose, in-house prepared freezing solution containing DMSO · In-house solution of Cryoserv/Edwards DMSO + dextran 40 + human albumin — Low cost, but composition variability and standardization are issues.
  • Passive freezing · Thermo Fisher Mr. Frosty / CoolCell (isopropanol-based and alcohol-free passive cooling containers) — For small scale and research use. Reproducibility of -1 °C/min is poorer.
  • Immediate administration of a fresh (non-frozen) product · (No freezing equipment needed) Immediate transport in a validated 2–8 °C container — Only where nearby manufacturing and short-term stability can be ensured.

Step guide

What you actually do

  1. Suspend the washed cells in chilled cryopreservation solution (containing DMSO, which protects the cells from ice) and bring cell number and volume to the product specification
  2. Keeping the system closed, dispense set volumes into freeze bags or cryovials for administration
  3. Seal the tubing and separate it, then freeze in a controlled-rate freezer following the set profile
  4. Store in the vapour phase of liquid nitrogen and record bag identification, storage position and temperature
  5. Together with the release decision, create the records of storage and packaging up to shipment to the treatment site

Decision points

What composition and DMSO concentration for the cryopreservation solution?
Ready-made serum-free solutions combining about 10% DMSO with albumin and the like are widely used. DMSO is also linked to side effects on administration (nausea, flushing and so on), so the options are to lower the concentration, to control the total amount administered, or to consider a DMSO-free protectant. The optimum changes with the cell type and there is no general right answer, so confirm it by viability and function after thawing.
Administer as it is without washing, or wash the DMSO out before administration?
Washing adds cell loss and open operations. In practice, where the freeze bag is infused intravenously as it is, the premise is that the total amount of DMSO has been held down at the formulation stage. Whether to reduce it in the formulation or remove it before administration is decided with the robustness of the cells, the practicalities at the treatment site and sterility side by side.
A controlled-rate freezer, or a passive freezing container?
Passive containers (isopropanol or alcohol-free cooling containers) are used at small scale and in research, but they are less reproducible at around 1 °C per minute and leave no record of the cooling. For a final product, a controlled-rate freezer that can control and record the profile is more often chosen.
Freeze, or administer fresh?
Freezing can be omitted only where the manufacturing site and the treatment site are close and stability over a short storage period has been confirmed. Where the product is administered fresh, the premise is that release testing is rapid, since the storage period is short.

Common mistakes

  • Using a passive freezing container for the final product, so that no record of the cooling is left and the reproducibility of the rate cannot be confirmed
  • Raising the cell density for freezing too far, so clumps form after thawing and viability falls
  • The allowed time from thawing to administration is not written into the procedures of the treatment site

Check at your own site

  • Is the DMSO in your cryopreservation solution calculated as the total amount administered to the patient and compared with an upper limit?
  • Is your post-thaw assessment a simple procedure that can be reproduced at the treatment site?

Quality attributes and analytics(9 steps)

Step 10: CAR expression rate

Confirms CAR surface expression and the percentage of positive cells. It is the identity of the product and a critical quality attribute (CQA) that underlies dose design.Confirms CAR surface expression and the percentage of positive cells. It is the identity of the product and a critical quality attribute (CQA) that underlies dose design.

Standard methodCAR-positive rate by flow cytometryCAR-positive rate by flow cytometry
Details and 3 alternatives

This step coversMeasurement of CAR expression and transduction efficiency (identity / efficacy) (CAR expression rate)

A check on "did we make it exactly as intended?" This step examines whether the marker called CAR appears on the cell surface.

Flow cytometry shines light on each cell, 1 cell at a time, and measures what percentage of all cells are CAR-positive. It shows whether the product is as designed.

This is the product's "proof of identity" and also the basis for designing the dose. It is an important quality attribute that supports both identity and dose.

Confirms that the CAR molecule is displayed on the cell surface as intended and what percentage of cells are CAR-positive. This is the identity of the product and an important quality attribute that also underlies dose design.

MakersMiltenyi Biotec, BioLegend, Beckman Coulter, Thermo Fisher, BD

Why it is the standard. Flow cytometry is the standard method that can quantify CAR surface expression at the cell level. Antigen (CD19-Fc)-based detection is specific to FMC63-based scFv and has low background. It is widely used in commercial and clinical identity tests.

Alternatives in practice

  • Protein L / anti-Fab generic detection · Biotinylated Protein L (Thermo Fisher 29997, etc.) + streptavidin fluorophore (BD/Thermo) — Detects diverse scFvs regardless of the target antigen. Specificity is somewhat lower.
  • Anti-idiotype antibody detection · Construct-specific anti-idiotype antibody (commercial/in-house, PE-labeled) — Highest specificity, but a dedicated reagent is required for each CAR.
  • Tag/reporter detection · Anti-Myc / anti-Strep-tag II antibodies, or antibody detection of co-expressed EGFRt/tCD19 (e.g., cetuximab-based anti-EGFR) — A tag must be designed into the construct.

Step guide

What you actually do

  1. Wash the cells, add a CAR detection reagent (an Fc fusion protein of the target antigen, a biotinylated reagent or the like), and stain with a fluorescently labelled secondary reagent, antibodies against T cell markers, and a viability dye
  2. Run the cells one by one through a flow cytometer and measure the fluorescence
  3. Narrow down to viable, CD3-positive cells and work out the proportion of CAR-positive cells among them
  4. Multiply the positive rate by the viable cell number to give the number of CAR-positive viable cells, and compare it with the dose

Equipment and materials

Materials and reagentsCAR detection reagent and fluorescent antibodies

Decision points

Which CAR detection reagent do you use?
A method using the target antigen (CD19-Fc and the like) is specific to that scFv (the part of the CAR that recognizes the antigen) and gives a low background. Protein L and anti-Fab antibodies do not depend on the target antigen and can detect a variety of scFvs, but are a little less specific. An anti-idiotype antibody is highly specific but needs a dedicated reagent for each CAR, and a method that builds a tag or a reporter such as EGFRt into the construct has to be decided at the design stage.
How do you set the line between negative and positive?
Use untransduced cells as the negative control, set the line with controls such as one that has all the other colours in and just 1 colour left out (FMO), and fix how the gate is placed in the written procedure. To reduce differences between analysts, record the gating conditions and, where necessary, consider automated gating. Also look at whether cells with weak CAR expression are being counted as negative.
Use it in release testing, or for in-process confirmation?
It is common to include it in release testing as confirmation of identity and to use it as the basis of the dose (the number of CAR-positive viable cells). Confirmation early after transduction is used as an in-process test, as material for reviewing the expansion conditions.

Common mistakes

  • Changing the lot of detection reagent without confirming its potency, so the positive-rate figures move
  • Counting cells with weak CAR expression as negative, and underestimating the positive rate
  • Using no viability dye, so the positive rate is worked out with dead cells included

Check at your own site

  • With which detection reagent and which negative control was your CAR-positive rate obtained?
  • Is your dose calculated as the number of CAR-positive viable cells? Not left as the total cell number?

Step 11: VCN measurement◇ Branches

A safety indicator that measures the copy number in 1 cell and keeps the tumorigenesis risk from insertional mutagenesis under control with an upper limit of an average of 5 copies or less.The measurement target changes from integrated provirus to transposon insertions plus residual nucleic acids

Standard methodAbsolute quantification by droplet digital PCR (ddPCR)Absolute quantification of transposon copy number by ddPCR, plus quantification of residual non-integrated minicircle DNA and residual transposase mRNA (clearance confirmed by western blot/qPCR)
ReagentsVector copy number testingddPCR/qPCR primers and probes targeting the transposon insert sequence and the transposase sequence
With Non-viral (Sleeping Beauty transposon / electroporation)Absolute quantification of transposon copy number by ddPCR, plus quantification of residual non-integrated minicircle DNA and residual transposase mRNA (clearance confirmed by western blot/qPCR)With Lentiviral vector (viral transduction)Absolute quantification by droplet digital PCR (ddPCR)
Details and 3 alternatives

This step coversVector copy number (VCN) measurement (safety) (VCN measurement)

A safety test that measures whether "too much gene was put in". It accurately counts how many copies of the virus entered 1 cell.

A high-precision method called ddPCR quantifies the copy number of the integrated vector as an absolute value. The count can be made with little variability.

Too many copies raise the risk of tumorigenesis through insertional mutagenesis. As a general guide, the upper limit is controlled at an average of 5 copies or less.

Measures how many copies of the virus are integrated in 1 cell. Too many copies raise the risk of tumorigenesis through insertional mutagenesis, so an upper limit is controlled as a regulatory safety indicator (generally an average of 5 copies/genome or less is the guide).

MakersBio-Rad, Thermo Fisher

Why it is the standard. ddPCR is absolute quantification without a standard curve, and its precision and reproducibility in the low-copy range are higher than qPCR. Results are stable across cryopreserved samples and across operators, and its use for VCN measurement is expanding (reported at ESMO IOTech and elsewhere).

Check also. The upper limit for the number of viral integrations per 1 cell (vector copy number) is often given as an average of 5 copies or less, but the required level differs by product and regulatory authority and is not a fixed value. Droplet digital PCR is well suited to absolute quantification, but values can shift with the design of the target sequence and genome-amount correction, so confirming the validity of the calibration is a prerequisite.

With Non-viral (Sleeping Beauty transposon / electroporation). Confirm that non-integrated minicircle and residual transposase fall below the limit of detection late in culture (roughly days 7–15)

Alternatives in practice

  • Real-time quantitative PCR · Thermo Fisher QuantStudio 5 / Bio-Rad CFX Opus + standard curve — Simpler than ddPCR, but inferior in absolute quantification accuracy and low-copy reproducibility.
  • CAR-positive rate by flow cytometry as a surrogate indicator · Clinical flow cytometer from [9] — A rapid surrogate for transduction efficiency. It cannot measure the copy number itself.
  • Next-generation sequencing (integration site analysis) · Illumina MiSeq/NextSeq + LAM-PCR/S-EPTS — Evaluates insertion sites and clonality. Excessive for routine VCN QC.

Step guide

What you actually do

  1. Extract genomic DNA from the product cells
  2. Mix primers and probes targeting a vector-derived sequence (WPRE and the like) and a reference gene present in 2 copies in the autosomes (RPP30 and the like), and divide the reaction mixture into tens of thousands of droplets
  3. Amplify in a thermal cycler, read each droplet as positive or negative, and derive the absolute number of both sequences
  4. Divide the number of vector sequences by the number of reference gene copies and multiply by 2 to give the average copy number per 1 cell (VCN)

What changes with the conditionWhether you quantify the VCN of the provirus from the viral route by ddPCR, or measure the copy number of the transposon from the non-viral (transposon) route together with the disappearance of residual unintegrated minicircle DNA and transposase mRNA (below the limit of detection late in culture, roughly 7 to 15 days) (what is measured changes from the integrated viral sequence to the inserted transposon and the residual nucleic acids)

Equipment and materials

Materials and reagentsDNA extraction kitddPCR reagents, primers and probesReference material (synthetic DNA of known copy number and the like)

Decision points

qPCR, or ddPCR (droplet digital PCR)?
ddPCR is absolute quantitation that needs no standard curve, and is a method that reproduces well even at low copy numbers. qPCR is simple and the instruments are widespread, but it needs a standard curve to be built up and there are reports of greater variability. External comparisons have also found ddPCR to agree better with expected values, so confirm the variability with your own samples using reference material before choosing.
Which reference gene and which target sequence do you use?
The value moves with the combination of target sequence (WPRE or the psi region) and reference gene (RPP30, albumin, PCBP2 and the like). State clearly which combination the specification figure was obtained with, and if you change the combination, review the validity of the specification as well.
How do you set the upper limit of the specification?
"Fewer than an average of 5 copies per 1 cell" has long been used as a guide, but in recent years it is said that how you justified the upper limit for your own product is asked about more often than the figure itself. 5 is a starting point; you need to be able to explain why you set your own upper limit at that value, and since VCN is an average over the population, it is not the same as a value for the transduced cells alone.

Common mistakes

  • Comparing the "5" of the specification with a value from another method as it stands, without confirming by which method and with which reference gene it was obtained
  • Taking VCN being within the specification as a substitute for RCL testing or insertion site analysis
  • Confusing the VCN averaged over the population with the average over the transduced cells alone

Check at your own site

  • With which reference gene and which method was your VCN specification value obtained, and why did you set that upper limit?
  • Is there a set procedure for reviewing your VCN specification when the method or the reference gene is changed?

Step 12: Cell count and viability

The number of CAR-positive viable cells administered is the dose itself. Viability indicates the soundness of the product and is central to the release specification.The number of CAR-positive viable cells administered is the dose itself. Viability indicates the soundness of the product and is central to the release specification.

Standard methodAutomated cell counting (image- and fluorescence-based live/dead discrimination)Automated cell counting (image- and fluorescence-based live/dead discrimination)
EquipmentCell counter
ReagentsChemoMetec Via1-Cassette (two-color immobilized staining cassette with acridine orange [total cells] + DAPI [dead cells]).
Details and 3 alternatives

This step coversCell count and viability measurement (dose and specification) (cell count and viability)

A test that determines "how many living cells will be administered". It measures viable cell number and viability, and is central to the release decision.

Imaging or fluorescence automatically judges live or dead for each cell, 1 cell at a time. In particular it measures the number of living CAR-positive cells and the overall viability.

Viable cell number is the dose itself, and viability is an indicator of the soundness of the product. Both are pillars of the release specification and important values that decide pass or fail.

The number of viable cells administered (especially CAR-positive viable cells) is the dose itself. Viability indicates the soundness of the product and is central to the release specification.

MakersChemoMetec, Beckman Coulter, Thermo Fisher

Why it is the standard. NucleoCounter is a closed-cassette automated counter widely used in cell therapy. The AO/DAPI two-color method gives stable live/dead discrimination even in cell therapy samples with abundant debris, and is often adopted for GMP routine use.

Alternatives in practice

  • Trypan blue dye exclusion (automated) · Beckman Coulter Vi-CELL BLU / Thermo Fisher Countess 3 FL — Simple and low cost. Discrimination of subtle dead cells is inferior to AO/DAPI.
  • Simultaneous live/dead and CAR quantification by flow cytometry · Clinical flow cytometer from [9] + viability dye — Viability and expression are obtained simultaneously from 1 sample. Low throughput.
  • Manual counting with a hemocytometer · Improved Neubauer hemocytometer + trypan blue — For backup/intermediate control. Large operator-to-operator variation.

Step guide

What you actually do

  1. Take a representative sample from the product and dilute it if necessary (it is sometimes measured both before freezing and after thawing)
  2. Draw the sample into a cassette loaded with acridine orange (all cells) and DAPI (dead cells), and put it into the automated counter
  3. From the images, the instrument gives the total cell number, the dead cell number, the viable cell number and the viability
  4. Multiply the viable cell number by the CAR-positive rate and other results, and confirm the dose for administration

Equipment and materials

Materials and reagentsCassettes and reagents for viability staining

Decision points

On which principle do you count?
Two-colour fluorescence staining (acridine orange and DAPI) is a method whose viability judgement tends to stay stable even with cell therapy samples full of debris. An automated trypan blue counter is simple and low in cost, but a little poorer at judging small dead cells. Flow can take viability and CAR expression at once but has low throughput, and a hemocytometer is for interim control or as a backup, with large differences between operators.
How do you design the measurement after thawing?
Decide in advance whether the instrument can handle samples containing DMSO or samples of high viscosity, and how you set the time from thawing to measurement. To see cell death that occurs later, measurement is sometimes made some time after thawing.
Where do you set the lower limit for viability?
It varies with the product and the risk; there is no single value. In cell therapy, examples set at 70% or above are often seen, but set it with a justification for each product. When few cells are counted the statistical scatter is large, so allow as well for the difference that manual counting of 100 cells gives a coefficient of variation of about 10%, while automated counting images a few thousand cells and brings it down to 1 to 2%.

Common mistakes

  • Counting a clump of cells as 1 cell, and setting the dose on a viable cell number lower than the reality
  • Not setting the time from staining to measurement, so trypan blue enters viable cells as well and the viability comes out low
  • Leaving the setting that counts debris as cells, and overestimating the viability

Check at your own site

  • Which sample, before or after thawing, and counted by which method, gives the viable cell number you use for the dose?
  • Have the gate settings of your counter been checked against another method?

Step 13: Immunophenotype and subset analysis

Examines the CD4/CD8 ratio, the memory ratio and exhaustion markers to control product consistency in terms of engraftment, persistence and efficacy.Examines the CD4/CD8 ratio, the memory ratio and exhaustion markers to control product consistency in terms of engraftment, persistence and efficacy.

Standard methodPhenotype analysis by multicolor flow cytometryPhenotype analysis by multicolor flow cytometry
ReagentsFluorescently labeled antibody panel: anti-CD3/CD4/CD8/CD45RA/CD45RO/CCR7 (CD197)/CD62L/PD-1 (CD279)/LAG-3/TIM-3 (BD Horizon / BioLegend / Beckman / Miltenyi) + viability dye BD Fixable Viability Stain / 7-AAD.
Details and 3 alternatives

This step coversImmunophenotype and subset analysis (purity and quality attributes) (immunophenotyping)

A test of the "inner quality" of the cell population. It analyzes in detail what types of T cells are present and in what proportions.

Flow cytometry with simultaneous staining in multiple colors reads out the CD4/CD8 ratio, the memory-to-effector ratio and the degree of exhaustion (PD-1, etc.).

These are quality attributes related to engraftment, persistence and efficacy. They are used to reduce lot-to-lot variability and keep the product consistent.

Examines the CD4/CD8 ratio, the ratio of memory (naive/central memory) to effector cells, and exhaustion markers (PD-1, LAG-3, TIM-3). These are quality attributes related to engraftment, persistence and efficacy, and are used to control product consistency.

MakersBD, Beckman Coulter, Cytek, BioLegend, Miltenyi Biotec

Why it is the standard. Multicolor flow cytometry is the standard method that can assess cell subsets and the activation/exhaustion state at the same time. It is common in clinical laboratories and widely used for CAR-T characterization and consistency evaluation.

Alternatives in practice

  • Spectral flow cytometry · Cytek Aurora / Sony ID7000 — High-dimensional analysis with more than 40 colors. Compensation is not needed, but unmixing is required.
  • Mass cytometry (CyTOF) · Standard BioTools CyTOF XT (formerly Fluidigm Helios) + metal-labeled antibodies — 40+ parameters without fluorescence overlap. Throughput is limited and cost is high.
  • Single-cell RNA-seq phenotyping · 10x Genomics Chromium + Illumina sequencer — Comprehensive transcriptome/CITE-seq. For characterization rather than QC.

Step 14: Potency measurement

Confirms that the cells recognize and kill their target and release cytokines. A potency test that shows the product's power to work and is essential from a regulatory standpoint.Confirms that the cells recognize and kill their target and release cytokines. A potency test that shows the product's power to work and is essential from a regulatory standpoint.

Standard methodIFN-γ production after antigen stimulation (functional potency)IFN-γ production after antigen stimulation (functional potency)
Details and 3 alternatives

This step coversMeasurement of potency: cytotoxic activity and cytokine production (potency measurement)

A potency test to confirm "does it really work?" This step actually tests whether the product can truly attack cancer cells.

CAR-T cells are stimulated with the target antigen, and the assay measures whether they release cytokines such as IFN-γ and can kill cancer cells. Function is what is verified.

This is proof that the product has the "power to work". It is regarded as essential from a regulatory standpoint, and it is an indispensable test for assuring efficacy.

Confirms that CAR-T cells recognize the target antigen, actually kill cancer cells and release cytokines. This is proof of the product's "power to work" and an essential potency test from a regulatory standpoint.

MakersAgilent, Tecan, ProteinSimple, Bio-Techne, BMG LABTECH

Why it is the standard. Antigen-dependent IFN-γ production is a representative functional potency indicator for CAR-T and is widely used for release and characterization testing because it is quantitative and easy to standardize. FDA asks that potency be demonstrated with a functional assay that reflects the mechanism of action (Potency Tests for Cellular and Gene Therapy Products, final version, January 2011; Potency Assurance for Cellular and Gene Therapy Products, draft, December 2023).

Check also. IFN-γ (interferon gamma) production on recognizing the target is an easy-to-handle potency indicator, but it is only a surrogate for whether the cells can actually kill cancer cells (cytotoxic activity). Regulatory potency must be based on the mechanism of action of each product, and it is desirable to evaluate cytokine production and cytotoxic activity together using different principles.

Alternatives in practice

  • Real-time cytotoxicity (impedance) · Agilent xCELLigence RTCA — Label-free, continuous acquisition of killing kinetics. Target cell adhesion is required.
  • Flow cytometry/dye-based cytotoxicity assay · [9] flow cytometer + CFSE/CellTrace + viability dye — Quantifies the specific killing rate, which depends on the E:T ratio.
  • Multiplex cytokine profiling · Bio-Techne/ProteinSimple Ella (automated multiplex ELISA) / Luminex MAGPIX — Measures IFN-γ/TNF-α/IL-2, etc. simultaneously to evaluate function from multiple angles.

Step guide

What you actually do

  1. Co-culture the product cells with a cell line that presents the target antigen (e.g. a CD19-positive cell line), or with beads carrying the antigen, mixed at a set ratio (the E:T ratio, the ratio of the numbers of effector to target cells)
  2. After a set time, take the supernatant and quantify IFN-γ by ELISA or by a bead-based multiplex measurement (intracellular staining read by flow is also possible)
  3. Measure the reference standard alongside to give a relative potency, or compare against the lower limit of the specification
  4. Record the result as the function of the lot, together with other measures such as CAR-positive rate and cytotoxicity

Equipment and materials

EquipmentPlate readerFlow cytometerReal-time cell analyzer
Materials and reagentsCytokine measurement kit (ELISA, bead array)Target cells or antigen beads (the system for the cell-based potency assay)Reference standard (the reference lot for the potency assay)

Decision points

What do you have to measure for it to represent potency?
Break the mechanism of action down (recognition, cytotoxicity, proliferation, persistence) and decide which measure assures each stage. Cytotoxicity is closer to the heart of potency but takes time and varies widely, while IFN-γ production is easy to quantify and to standardize and so is widely used; since it is not cytotoxicity itself, using it for release needs a bridge that shows the correlation with cytotoxicity in real data. FDA asks that potency be shown in a functional assay that follows the mechanism of action.
A live target cell line, or beads carrying the antigen?
A target cell line loses antigen expression over repeated passaging, so it needs a cell bank to be made and an upper limit on passage number to be controlled. Antigen beads are a proposal that removes the variable of managing a cell line; there are reports of full validation for CD19 CAR-T and of qualification for CD7 and HER2 CAR-T as well. The correlation with cytotoxicity has to be confirmed with your own product.
A single measure, or a bundle of them?
Where the mechanism of action is many-sided, there is a matrix approach that gives each stage its own measure and bundles them. The more measures you add, the more complex the logic of setting specifications and integrating results, so the condition is that you can explain which stage of the mechanism each measure covers and why that bundle can represent potency as a whole.
Do you use a reference standard and relative potency?
Cell-based assays move in absolute value from day to day. Measuring the reference standard alongside on the same day and dividing by the state of the system that day cancels the day-to-day difference. For autologous products, where a reference standard is itself hard to make, there are designs that substitute cells from healthy donors or a cell line, but allow for the fact that their properties differ from the product.

Common mistakes

  • Repeated passaging of the target cell line lowers antigen expression, so the potency of the product comes out low
  • Measuring at only 1 E:T ratio, and failing to catch differences between lots
  • Using the amount of IFN-γ produced in place of cytotoxicity while holding no correlation data

Check at your own site

  • Which stage of the mechanism of action does your potency assay represent, and what assures the other stages?
  • Up to which passage have you decided to use your target cell line, and what do you use to confirm antigen expression?

Step 15: RCL testing◇ Branches

Confirms that the vector has not regained replication competence and become an infectious virus. A safety test required by regulation.No lentivirus is used, so there is no route for a replication-competent lentivirus (RCL) to arise

Standard methodqPCR detection of provirus sequences after amplification in susceptible cells (RCL testing)RCL testing is not applicable. Instead, residual transposase mRNA/protein and non-integrated minicircle DNA (their persistence and clearance) become the control items
ReagentsRCR / RCL testingqPCR/western blot reagents for transposase detection
With Non-viral (Sleeping Beauty transposon / electroporation)RCL testing is not applicable. Instead, residual transposase mRNA/protein and non-integrated minicircle DNA (their persistence and clearance) become the control itemsWith Lentiviral vector (viral transduction)qPCR detection of provirus sequences after amplification in susceptible cells (RCL testing)
Details and 3 alternatives

This step coversRuling out replication-competent virus (RCL/RCR) (safety) (RCL testing / ruling out replication-competent virus)

A safety test that rules out "the virus having run out of control". It examines whether the virus used in manufacturing has regained infectivity.

The cells are first amplified in highly susceptible cells, and qPCR looks for the trace (provirus sequence) that would appear if a replication-competent virus were present.

If one were present, it would be a serious risk of insertional mutagenesis and viremia. This is a test required by regulation to show that it is "not there".

Confirms that the viral vector used in manufacturing has not regained the ability to self-replicate and become an infectious virus. Its presence would be a serious risk of insertional mutagenesis and viremia, so this is a safety test required by regulation.

MakersBio-Rad, PerkinElmer, Thermo Fisher, Takara

Why it is the standard. FDA guidance (Testing of Retroviral Vector-Based Human Gene Therapy Products for Replication Competent Retrovirus During Product Manufacture and Patient Follow-up, January 2020) recommends RCR/RCL testing of each lot of transduced cells, and a 2-stage design of an amplification phase plus a detection phase (sequence PCR plus 2 independent methods such as PERT/p24) is the standard. The ASGCT procedures of Cornetta et al. are widely referenced.

Check also. Replication-competent virus testing is meaningful only for processes that use viral vectors; non-viral processes have no such target (it is replaced by control of items such as residual transposase). The standard method, which involves amplification in susceptible cells, takes days to give a result, so for CAR-T with its short shelf life the test must be designed so that it does not become the rate-limiting step for release.

With Non-viral (Sleeping Beauty transposon / electroporation). The RCL monitoring FDA requires (producer cells, final product, patient samples) is no longer needed, but the risk of remobilization due to persistent transposase expression must be assessed

Alternatives in practice

  • PERT (product-enhanced reverse transcriptase) assay · qPCR-based PERT (e.g., SG-PERT, Bio-Rad/Thermo cyclers) — Detects RT activity with high sensitivity. Useful for general screening.
  • p24 antigen ELISA (HIV-1 vector) · Takara/Clontech Lenti-X p24 Rapid Titer Kit / PerkinElmer HIV-1 p24 ELISA — An indicator of free particles/contamination in lentiviral systems.
  • RCR testing for gamma-retroviral products · Extended S+L- focus assay / PG4 cells — Replication-competent virus testing for retroviral vector products.

Step guide

What you actually do

  1. Take as the test sample an amount set in line with the guidance of the authorities, from the product cells or from the cells left after the vector was made
  2. Add it to susceptible cells (e.g. C8166) and amplify for several weeks, so that any replication-competent virus will grow
  3. Extract DNA from the amplified cells and examine packaging sequences such as VSV-G (the protein used for the envelope of the vector) by PCR
  4. Run a positive control spiked with a small amount of known replication-competent virus through the same procedure, confirm that it can be detected, and then judge the result

What changes with the conditionWhether, with the viral route, RCL testing is done for every lot, or, with the non-viral (transposon) route, RCL testing is taken as not applicable because there is no pathway for replication-competent lentivirus to arise at all, and the control items become instead the residual transposase mRNA and protein and the disappearance of unintegrated minicircle DNA (if transposase remains there is a risk of remobilization, so that assessment is required)

Equipment and materials

Materials and reagentsRCL detection kitSusceptible cells (indicator cells)DNA extraction kit

Decision points

The culture method, PCR, or a combination?
The culture method is regarded as the standard: the sample is grown in permissive cells for several weeks, and it takes about 4 to 6 weeks to reach a judgement. For PCR there are digital PCR kits targeting the VSV-G sequence, which give results quickly, but as they only look at the sequence, leftover plasmid also comes out positive. Set the procedure for confirming a positive PCR result by the culture method before the test, and for cell products administered fresh, where the culture method cannot be waited for, there are examples of using an alternative method after consulting the authorities.
Which sample do you test, and at which stage?
Not only the product but the vector bulk, the cells left after the vector was made, the product after transduction, and even patient samples after administration come into one continuous plan. Cells at the point where vector production finished cannot be prepared again later in the same state, so confirm that the instruction to take them is in the manufacturing record.
Once a record of negative results has built up, can testing be reduced?
For a cell product with a sufficient record of negative results, there is a route to reducing testing after consulting the authorities. In that case it is recommended that part of the product be kept so that it can be tested in future. The decision on whether to reduce follows the outcome of consultation between the quality unit and the authorities.

Common mistakes

  • Confusing the test name on the request form (RCL, RCR, RCA, rcAAV) with the type of vector used
  • Not putting collection of the cells left after the vector was made into the manufacturing record, so no sample can be taken later
  • Overlooking that a positive PCR result cannot distinguish leftover plasmid from replication-competent virus

Check at your own site

  • Does your RCL testing base the release decision on the culture method or on PCR, and is the confirmation procedure for a positive result set?
  • Does your manufacturing record include the instruction to keep the cells left after the vector was made?

Step 16: Sterility test

Rules out bacterial and fungal contamination of a living-cell product that cannot be terminally sterilized, to prevent serious infection on administration.Rules out bacterial and fungal contamination of a living-cell product that cannot be terminally sterilized, to prevent serious infection on administration.

Standard methodPharmacopoeial sterility test (membrane filtration / direct inoculation)Pharmacopoeial sterility test (membrane filtration / direct inoculation)
Details and 3 alternatives

This step coversSterility testing (ruling out microbial contamination) (sterility test)

A sterility test that confirms "no stray microbes got in". It matters because CAR-T is a living-cell product that cannot be sterilized afterward.

Using pharmacopoeial methods, the absence of bacterial and fungal contamination is confirmed by filtration through a filter or by direct inoculation. The product is tested as living cells.

Contamination would cause serious infection on administration. Because the shelf life is short, a rapid method whose results arrive in time is also required.

CAR-T is a living-cell product that cannot be terminally sterilized. Unless the absence of bacterial and fungal contamination is confirmed, administration can cause serious infection. A rapid method that fits within the short shelf life is also required.

MakersMerck, Sartorius, bioMérieux, Merck Millipore, BD

Why it is the standard. USP <71> / EP 2.6.1 are the pharmacopoeial standards for sterility. For frozen products that can be stored for a long time, they play a confirmatory role. In the US, testing is required to be done by the methods in 21 CFR 610.12 and USP <71>, or by a method shown to be equivalent. For living-cell products with a short shelf life, a 14-day incubation is not workable, so a rapid method that detects growth is used, with validation of equivalence. FDA issued draft guidance on the approach to such validation in February 2008. The responsibility for demonstrating equivalence lies with the manufacturer.

Check also. Living-cell products cannot be terminally sterilized, so assuring sterility is essential. But the standard pharmacopoeial sterility test takes roughly 14 days to reach a result, which is too late for the release decision of CAR-T with its short shelf life. Use of a rapid method (automated culture or nucleic acid amplification) alongside is assumed, and when a rapid method is used, equivalence validation against the standard method is required.

Alternatives in practice

  • Rapid sterility test using an automated blood culture system · bioMérieux BacT/ALERT 3D / BD BACTEC FX — A rapid method essential for short-shelf-life products. Equivalence validation against USP <71> is required.
  • PCR/nucleic acid-based rapid microbial detection · Rapid molecular methods (e.g., each vendor's rapid micro method) — Results within hours. Equivalence verification against culture methods is a prerequisite.
  • Gram staining (in-process control) · Light microscope + Gram stain kit — For in-process monitoring, not for release decisions.

Step guide

What you actually do

  1. Take a representative sample from the product aseptically (the final product, or the last intermediate of the process)
  2. Put it into fluid thioglycollate medium and soya-bean casein digest medium, by membrane filtration (filtering the sample through a membrane to collect organisms and putting it into medium) or by direct inoculation
  3. The pharmacopoeial method cultures for 14 days and looks for turbidity or growth. A rapid method detects earlier, from a signal (CO₂ and the like) given off by an automated culture bottle
  4. Record as well the confirmation that the medium can grow organisms (growth promotion test) and the results of the positive and negative controls

Decision points

The pharmacopoeial 14-day culture, or a rapid method?
For products that can be frozen and stored for a long time, there is a view that positions the pharmacopoeial method as a confirmation, but products with a shelf life of hours to days cannot wait 14 days. Using a rapid method (an automated blood culture system and the like) presumes validation showing equivalence to the pharmacopoeial method in limit of detection, specificity and robustness, and the responsibility for showing equivalence lies with the manufacturer. In the United States, 21 CFR 610.12 requires either the pharmacopoeial method or a method shown to be equivalent.
Which stage do you take the sample from for testing?
The whole of the final product cannot be tested, so combine the representativeness of the sample drawn with in-process testing (during culture, after washing). For autologous products, where sample volume is small, the amount that can be spared for testing is limited, which raises the value of rapid methods and of tests that work with small volumes.
How do you handle attributes that are only confirmed after release?
There is a design in which the product is released conditionally, on the basis of the rapid-method result and of process controls such as environmental monitoring and media fills, with the confirmatory 14-day culture checked afterwards. The procedure for notifying the treating physician, investigating and correcting if it turns positive is set in advance as an approved procedure, and the quality unit decides.

Common mistakes

  • Taking a negative result as proof of sterility, and relying on the test rather than building sterility into the process
  • When introducing a rapid method, not including the organisms detected in your own environment in the verification of equivalence
  • The sample volume spared for testing is small, so the growth promotion and control checks are omitted

Check at your own site

  • How many days does it take for your sterility test result to come out, against the shelf life of the product? What covers the part that does not fit in time?
  • With which organisms, and down to which limit of detection, was the equivalence of your rapid method confirmed?

Step 17: Mycoplasma and endotoxin testing

Rules out hard-to-see mycoplasma and pyrogenic endotoxin before release. Rapid methods are used because of the short shelf life.Rules out hard-to-see mycoplasma and pyrogenic endotoxin before release. Rapid methods are used because of the short shelf life.

Standard methodMycoplasma detection by rapid PCR + endotoxin quantification by the kinetic turbidimetric/chromogenic LAL methodMycoplasma detection by rapid PCR + endotoxin quantification by the kinetic turbidimetric/chromogenic LAL method
Details and 3 alternatives

This step coversMycoplasma and endotoxin testing (safety) (mycoplasma and endotoxin testing)

A test aimed at contamination that is hard to see. It rules out mycoplasma, which is hard to notice in culture, and endotoxin, which causes fever.

Mycoplasma is detected by rapid PCR, and endotoxin is quantified by the kinetic turbidimetric/chromogenic LAL method. Both are tested quickly.

Both harm the patient when administered. Because the shelf life is short, rapid and kinetic methods are used to rule them out reliably before release.

Mycoplasma is a contaminant that is hard to see in culture and easy to introduce, and endotoxin is a pyrogen. Both are harmful when administered, so they are ruled out before release. Because the shelf life is short, rapid PCR and kinetic methods are used.

MakersLonza, bioMérieux, Charles River, Associates of Cape Cod, Thermo Fisher

Why it is the standard. For CAR-T with a short shelf life, the 28-day pharmacopoeial culture method (USP <63>) is too slow, so validated rapid PCR (an alternative to USP <63>) and rapid LAL (USP <85>/EP 2.6.14) are the standard. Endosafe-PTS is widespread in GMP for its small sample volume and short run time.

Alternatives in practice

  • Pharmacopoeial mycoplasma culture method + indicator cell method · Hoechst staining (DNA-binding dye) + Vero/3T3 indicator cells, broth/agar culture — Classical method requiring 28 days. The comparison reference for establishing equivalence of rapid PCR.
  • Gel-clot LAL · Lonza/Associates of Cape Cod gel-clot LAL reagent — Simple and low cost. Semi-quantitative and less rapid.
  • Recombinant factor C (rFC) method · Lonza PyroGene rFC Assay / bioMérieux ENDONEXT EndoZyme II — Does not use horseshoe crab-derived LAL (addresses animal welfare). Kinetic fluorescence measurement.

Step guide

What you actually do

  1. Take samples from the product cells and the supernatant, and extract nucleic acid for mycoplasma (both cells and supernatant are tested)
  2. Amplify and detect mycoplasma sequences by real-time PCR. Confirm as well, with an internal control, that amplification is not being inhibited
  3. For endotoxin, put the sample into a dedicated cartridge or plate and measure the concentration from how the colour of the LAL reagent (a reagent derived from the horseshoe crab) develops (kinetic chromogenic method)
  4. Confirm with a positive product control (PPC), in which a known amount is added to the sample and recovery is examined, that the sample is not interfering

Equipment and materials

Materials and reagentsMycoplasma detection kit (NAT)Nucleic acid extraction kitEndotoxin standard and LAL reagent waterMycoplasma reference material (standard)

Decision points

For mycoplasma, the culture method with the indicator cell method, or nucleic acid amplification (NAT)?
The culture method takes 28 days and cannot meet a release decision for a product with a short shelf life. NAT gives a result in a few hours to 1 day, but it does not distinguish live from dead and gives false negatives if the sample inhibits it. For products with a short shelf life, use NAT and show that it meets the pharmacopoeial requirements, including limit of detection and standards (the revision of European Pharmacopoeia 2.6.7 that came into force in April 2026 positioned NAT as a method equivalent to the indicator cell method).
Which endotoxin method do you use?
The gel-clot method suits a limit test, while kinetic turbidimetric and chromogenic methods suit quantitation. The cartridge format can measure in a short time with a small sample, so it is widely used in cell therapy. The recombinant factor C (rFC) method avoids reagents derived from the horseshoe crab, but decide on its adoption according to the product and the regulatory situation.
How do you set the limit value and the dilution limit?
Calculate the limit value from the dose by the formula K divided by M, and dilute within the maximum valid dilution (MVD), which keeps the sensitivity, to avoid interference. Since sample volume is small in cell therapy, confirm at the test design stage that the test works within this range.

Common mistakes

  • Taking the absence of anything unusual to the eye as the basis for mycoplasma being negative
  • Overlooking that PCR alone cannot distinguish whether a NAT positive is live organisms or debris
  • Not examining interference from the cryoprotectant or medium components, and diluting beyond the maximum valid dilution

Check at your own site

  • Does your mycoplasma test state the limit of detection, including the provenance of the standard?
  • Does your endotoxin test confirm the absence of interference within the maximum valid dilution of the product?

Step 18: Control of process-related impurities

Confirms that residual beads, residual DMSO, residual vector and others are at or below the specified values, minimizing impurities carried into the patient.Confirms that residual beads, residual DMSO, residual vector and others are at or below the specified values, minimizing impurities carried into the patient.

Standard methodCounting of residual magnetic beads and quantification of residual reagentsCounting of residual magnetic beads and quantification of residual reagents
Details and 3 alternatives

This step coversControl of residual impurities (process-related impurities) (control of process-related impurities)

A test of "are we bringing in anything extra?" It confirms that impurities mixed in during manufacturing are within the acceptance limits.

Remaining magnetic beads are counted, and residual DMSO, residual vector and culture-derived cytokines are quantified. The test checks that none exceeds the specified values.

Keeping these process-related impurities to a minimum leads to patient safety. It is the finishing safety check.

Confirms that residual activation beads, residual DMSO, residual vector, culture-derived cytokines and the like are at or below the specified values. This minimizes the impurities carried into the patient and assures safety.

MakersAgilent, ChemoMetec, Tecan, ProteinSimple, Bio-Techne

Why it is the standard. In bead-activation processes, it is standard for the release specification to include the residual bead count (e.g., an upper limit per product). For soluble reagents (TransAct), residual reagent evaluation substitutes for it, and confirmation by other methods depends on the process.

Alternatives in practice

  • Measurement of residual DMSO/additives · Agilent headspace GC-FID (7890/8890) / GC-MS — Solvent residues in the frozen product are controlled in the release specification.
  • Quantification of residual cytokines/medium components · R&D Systems/Bio-Techne ELISA / ProteinSimple Ella — Quantifies carry-over of IL-2 and the like. For immunogenicity and specification compliance.
  • Evaluation of residual vector (free particles) · Takara Lenti-X p24 / VSV-G qPCR (QuantStudio/QX200) — Risk assessment of contamination by free vector particles.

Step guide

What you actually do

  1. For products that used magnetic beads, look at the sample under a microscope or in an imaging counter and count the residual beads
  2. Quantify the DMSO in the frozen formulation by headspace gas chromatography (GC)
  3. Measure cytokines such as IL-2, and residues of the activation reagent, by ELISA or similar
  4. For the viral route, examine free vector particles and residual nucleic acid by p24 ELISA (a method that measures the capsid protein of the vector) or by qPCR

Decision points

What do you put into the specification as an impurity?
Write out the materials used in the process one by one, judge whether each can remain in the product, and decide from that. In a process that activates with beads, the residual bead count usually enters the release specification; with a soluble activation reagent, it is replaced by assessment of residual reagent. Some attributes go unmeasured by anyone unless they are in the specification, so work them out at the same time as the process design.
How do you set the upper limit for DMSO?
Set it as the total amount administered (per body weight), together with the formulation design. Looking at concentration alone, the total becomes large for patients with a high dose. How the upper limit is set is worked out including consultation with the authorities and the practice at the treatment site (whether it is diluted before administration or infused as it is).
How much distance do you leave between the limit of detection and the specification?
Setting the specification right at the limit of detection produces failures from measurement scatter. The real level of control is set by the specification value, so leave distance in advance between what can be measured and the specification.

Common mistakes

  • Not writing out the materials used in the process, so that a material not in the specification remains in the product
  • Setting the specification right at the limit of detection, so that failures come from measurement scatter
  • Looking at DMSO by concentration alone and not by the total amount administered

Check at your own site

  • Does your residual impurity specification write out the materials used in the process one by one and keep the justification for including or excluding each?
  • Is your residual DMSO compared with an upper limit as a total administered amount per body weight?

Guides that go deeper

The reference (“gold standard”) method is the one broadly recognized in published practice and guidelines; your process, product and regulator may justify another. Makers and products are examples, not endorsements. This map is translated from the Japanese edition, where it is updated first (Japanese version).