Skip to content

Gene therapy Process map

Plasmid DNA

This reference process map organizes the manufacturing and analysis of plasmid DNA in the order of E. coli fermentation → cell harvest and lysis → purification → characterization. The best method depends on conditions, so each step also lists alternative and complementary methods. At the end, it also covers 2 routes for making linear DNA cell-free, by PCR amplification or enzymatic synthesis (doggybone, dbDNA), without using plasmids (E. coli), together with their purification and the reagents used.

Editor's note. Whether plasmid purification succeeds is in fact decided at lysis, before chromatography. Alkaline lysis is the standard because it is inexpensive and releases the plasmid from E. coli all at once, but if mixing is too vigorous, genomic DNA is fragmented and can no longer be separated by the downstream AEX, and the SC content stalls. The scale-up of this 'gentle mixing' is where transfers stumble most. The reason HIC is added when AEX alone cannot clear gDNA and RNA is that raising and lowering the salt concentration alone can push out isoforms and endotoxin at the same time; the resin is cheap, but behind it lie the cost of handling large amounts of salt and the effort of buffer design. The %SC measured by CGE is the leading character of the final specification, and designing the whole process backward from it is the practical key.

Used to makemRNA-LNP, AAV vectors, Lentiviral vectors

In addition to circular plasmids made in E. coli, this map also covers cell-free routes that do not use E. coli (PCR amplification/enzymatic synthesis, doggybone, dbDNA) and the common purification. To the cell-free routes →

At a glance

Select a step to jump to its card. ◇ marks a step whose standard method changes with the condition.

  1. Starting materials and cell banks1 step
    1. Cell bank construction, identity confirmation
  2. Cell culture and production1 step
    1. Main culture, fermentation
  3. Harvest and clarification3 steps
    1. Harvest, cell recovery
    2. Alkaline lysis, neutralization (changes with the condition)
    3. Clarification, depth filtration (changes with the condition)
  4. Purification5 steps
    1. UF/DF, concentration
    2. Precipitation, conditioning (changes with the condition)
    3. Capture / anion exchange
    4. Polishing / hydrophobic interaction
    5. Final polishing, desalting
  5. Formulation and fill-finish1 step
    1. Final filtration, fill-finish
  6. Quality attributes and analytics9 steps
    1. Supercoiled content analysis
    2. Identity confirmation
    3. Content, purity / UV measurement
    4. Residual host DNA/qPCR
    5. Residual HCP/ELISA
    6. Residual RNA (residual RNA analysis)
    7. Endotoxin test (LAL)
    8. Sterility and bioburden tests
    9. General physical property tests
  7. Linear DNA (1): PCR amplification route2 steps
    1. Starting materials for the PCR method
    2. PCR method, drug substance equivalent
  8. Linear DNA (2): enzymatic synthesis route3 steps
    1. Starting material for the enzymatic synthesis…
    2. Phi29 polymerase, RCA
    3. Doggybone formation
  9. Linear DNA (3): purification and finishing2 steps
    1. Selective removal of residual DNA
    2. Linear DNA drug substance

Starting materials and cell banks(1 step)

Step 1: Cell bank construction, identity confirmation

Identity confirmation that fixes the state of the right bacteria carrying the plasmid with the right sequence, the starting point of the whole process.Identity confirmation that fixes the state of the right bacteria carrying the plasmid with the right sequence, the starting point of the whole process.

Standard methodCell bank preparation of transformed E. coli + full-length plasmid sequence confirmationCell bank preparation of transformed E. coli + full-length plasmid sequence confirmation
Details and 3 alternatives

This step coversConstruction of master/working cell banks of the host E. coli and identity confirmation (cell bank construction, identity confirmation)

Plasmid is propagated not in a test tube but inside E. coli. So the starting point is to prepare, as the seed, a single bacterium 'carrying the right blueprint correctly.'

The seed culture is dispensed uniformly and frozen so that quality is the same in every lot. This is the cell bank, and for each manufacturing run, bacteria are revived from here and grown.

What matters is reading the full-length sequence of the plasmid before storage to fix identity. If the foundation wavers here, however much the later steps are polished, the blueprint itself is off.

Plasmid is propagated inside E. coli. The seed bacteria are frozen uniformly so that every lot can be grown at the same quality. Fixing at the start that 'the right bacteria carry the plasmid with the right sequence' is the starting point of the whole process.

MakersBio-Rad, Agilent, Biotype, Illumina, bioMérieux

Why it is the standard. Plasmid is a 'critical starting material,' and confirmation of sequence identity is mandatory (EMA gene transfer guideline, Ph.Eur 5.14). Sanger is widely required as the de facto standard method for identity confirmation in gene and cell therapy CMC.

Alternatives in practice

  • NGS full-length sequence confirmation · Illumina MiSeq (v2/v3 reagent kits) or Oxford Nanopore MinION (whole-plasmid consensus) — Strong at comprehensive detection of mutations and rearrangements, and outsourcing to services such as Plasmidsaurus is also possible. Avoids the read-length limit of Sanger
  • Restriction enzyme fingerprinting · Agilent 4200/5200 Fragment Analyzer or Bio-Rad agarose gel + GelDoc Go imager — Simple identity confirmation by matching the cleavage patterns of multiple enzymes. No sequence information is obtained
  • Host 16S rRNA identification/phenotype · bioMérieux VITEK 2 or Bruker MALDI Biotyper (MALDI-TOF MS) — Prevents mix-ups of the host strain (DH5α/DH10B, etc.). Confirms the identity of the bacterial cells, not of the plasmid

Step guide

What you actually do

  1. Introduce the plasmid of interest into the host E. coli (for example DH5α or DH10B) (transformation)
  2. Using selection (antibiotic resistance, or an antibiotic-free selection system), keep only the cells carrying the plasmid and grow them
  3. Mix the grown cells uniformly, dispense them into vials together with a cryoprotectant such as glycerol, and store them in two tiers, the MCB (master cell bank) and the WCB (working cell bank)
  4. Recover the plasmid and record the restriction digest pattern and the full-length sequence (Sanger or next-generation sequencing) against the design
  5. Confirm the identity of the host strain itself as well, by a separate method (16S rRNA, MALDI-TOF and the like)

Decision points

What governs the choice of host strain?
Strains in which endA and recA are inactivated, such as DH5α and DH10B, are commonly used. The endA deletion suppresses nicking during purification (supercoiled molecules turning into open circular ones), and the recA deletion suppresses recombination of repeat and palindromic sequences. Choose a strain that keeps the sequence intact without destroying the supercoiled form, not one that simply grows well.
Is selection by antibiotic, or by an antibiotic-free system?
Regulatory authorities have repeatedly recommended avoiding the use of antibiotic resistance markers, and for GMP products an antibiotic-free selection system is a candidate where residues are to be avoided. Systems such as Nanoplasmid (Aldevron), ORT and RNA-OUT need a dedicated host and vector, so settle the approach at an early stage of development.
Is sequence confirmation by Sanger or next-generation sequencing?
As a critical starting material, the plasmid is required to have its sequence identity confirmed. Sanger is widely used but has a read length constraint. Next-generation sequencing (including whole-circle nanopore reading) can detect mutations and rearrangements comprehensively. Restriction patterns are simple but give no sequence information.
How do you decide the bank tiers and the number of vials?
The MCB is used only to make a WCB, and manufacturing starts from the WCB. Estimate the number of vials from how many times the WCB will be remade over the whole product lifetime, and control characterization such as strain identity, antibiotic resistance markers and the plasmid restriction map on the same thinking as for biologics.

Common mistakes

  • Doing the sequence confirmation on only part of the region, and learning of a full-length mutation or rearrangement for the first time in a later step
  • Choosing a strain that grows well without confirming the host's genetic background, so that supercoiled content falls through nicking or recombination during purification
  • Proceeding on the assumption that antibiotics will be used, and later having to rebuild from host and vector in order to switch to an antibiotic-free system

Check at your own site

  • Has the plasmid in your own bank had its identity confirmed by the full-length sequence?
  • On what assumption about handling antibiotic residues was your own selection marker decided?

Cell culture and production(1 step)

Step 2: Main culture, fermentation

The main culture, in which fed-batch grows cells to high density while preserving copy number, and determines the final yield and the supercoiled fraction.The main culture, in which fed-batch grows cells to high density while preserving copy number, and determines the final yield and the supercoiled fraction.

Standard methodFed-batch fermentation, defined medium, dissolved oxygen/pH/temperature controlFed-batch fermentation, defined medium, dissolved oxygen/pH/temperature control
Details and 3 alternatives

This step coversPlasmid amplification by fed-batch culture of E. coli (main culture, fermentation)

The central step where plasmid is actually 'mass-produced.' The seed culture is first expanded in flasks and then moved to the main culture in a culture vessel called a jar fermenter.

The fed-batch method (adding nutrients little by little) is used here. By topping up rather than giving everything at once, the cells are grown to high density while the amount of plasmid per 1 cell is also preserved.

In other words, it is a step that balances 'the number of cells' and 'the share per 1 cell,' and the cell mass and culture conditions here almost entirely decide the final yield.

The seed culture is expanded in shake flasks and then grown in the main culture in a jar fermenter. In the fed-batch mode, nutrients are added little by little to grow the cells to high density, maximizing overall yield while also preserving the amount of plasmid per 1 cell (copy number). The cell mass and culture conditions here determine the final yield.

MakersCytiva, Sartorius, Eppendorf, Corning, Teknova

Why it is the standard. A standard high-yield approach in which cell density of 40–60 g/L and pDNA of the 1–2 g/L class have been reported for high-copy plasmids (BioPharm International). Feed control is directly tied to achieving both plasmid yield and quality (supercoiled fraction).

Check also. Selection with antibiotics (such as kanamycin) to achieve high copy number is simple, but residual antibiotic in the final drug product and carrying over the resistance gene on the plasmid become regulatory issues. For projects that want to avoid this, designing an antibiotic-free selection system (such as auxotrophic complementation) from the beginning leads to less backtracking.

Alternatives in practice

  • Batch culture · Sartorius Biostat B / Eppendorf BioFlo 320 (benchtop to mid-scale) — Simple, but copy number and yield are inferior to fed-batch. For early development
  • Antibiotic-free selection (operator repression/auxotrophic complementation) · Host/vector of the Cobra Biologics ORT (Operator-Repressor Titration) system or the Nature Technology RNA-OUT system — When avoiding antibiotic residue in a GMP drug product. A dedicated host strain is required
  • Temperature-shift-induced copy number amplification · Eppendorf BioFlo 320 (30→42 °C shift control) — Temperature-sensitive copy number amplification derived from the pUC-type ori. Medium-independent, but heat stress management is needed

Step guide

What you actually do

  1. Thaw 1 vial of the WCB and pre-culture it in a flask
  2. Via a seed bioreactor, inoculate the main culture vessel (a single-use stirred tank or a stainless steel vessel)
  3. Culture in defined medium while adding the carbon source (glycerol or glucose) feed solution a little at a time (fed-batch)
  4. Control dissolved oxygen, pH, temperature, aeration and agitation, and decide the time of harvest while watching off-gas analysis and the trend in cell density
  5. Take samples and confirm the plasmid yield and the supercoiled content

Decision points

Fed-batch or batch?
Fed-batch makes it easier to grow cells to high density and to hold the plasmid quantity per cell, so it is the norm at commercial scale. Batch is simple, but its copy number and yield are lower than fed-batch, so it suits early development. Putting in a large amount of carbon source at the start lets acetate accumulate, which hinders both growth and plasmid maintenance.
What governs the choice of vessel?
Choose on oxygen transfer capability (kLa) and turndown ratio, not on the total volume of the vessel. High-density E. coli culture has a large oxygen demand and kLa readily becomes rate-limiting. Single-use units need less initial investment and less CIP/SIP effort, while stainless steel can be used repeatedly. Confirm with the maker the kLa at the smallest volume you will actually charge and the upper oxygen demand of your own strain.
How do you decide the time of harvest?
Harvest at the point where amplification of copy number and maintenance of quality are both achieved. Growing the cells as dense and as long as possible does not translate into good material, and the deeper you go into stationary phase, the more readily supercoiled molecules turn into open circular ones. For plasmids whose copy number is raised by temperature induction, the time of the temperature shift (for example from 30 °C to 37-42 °C) is also part of the conditions.
Do you keep adding antibiotic during culture?
A design that adds antibiotic to maintain selection pressure comes with confirmation of residues and confirmation that they can be removed. Switching to an antibiotic-free system requires a dedicated host and vector.

Common mistakes

  • Choosing the vessel on the catalog total volume, so that the kLa at the smallest volume actually charged is insufficient
  • Putting in the carbon source all at once, so that acetate accumulates and both growth and plasmid maintenance are hindered
  • Growing dense and long raised the yield, but the supercoiled content fell and cannot be recovered in purification

Check at your own site

  • Is your own harvest time decided from measurements of plasmid yield or of supercoiled content?
  • Has your own vessel had its kLa confirmed at the smallest volume you actually charge?

Harvest and clarification(3 steps)

Step 3: Harvest, cell recovery

Standard pretreatment that concentrates cells and removes medium components before lysis. Uniformity of resuspension determines recoveryStandard pretreatment that concentrates cells and removes medium components before lysis. Uniformity of resuspension determines recovery

Standard methodContinuous disc-stack centrifugation or hollow fiber microfiltrationContinuous disc-stack centrifugation or hollow fiber microfiltration
Details and 2 alternatives

This step coversHarvest, concentration and resuspension of cells → biomass concentration and medium removal by centrifugation or microfiltration, and resuspension in lysis buffer (harvest, cell recovery)

The liquid after culture is in a state where the cells are thinly spread, and it cannot go on as is to the step that breaks them. First only the cells are collected and concentrated, and unneeded medium components are washed off.

Collection is by centrifugation or microfiltration. The collected clump of cells is evenly redissolved (resuspended) in the dedicated buffer to be used for the next lysis, completing the preparation.

Unglamorous but needing attention is this redissolving. If lumps remain and it is uneven, the next alkaline lysis works poorly and plasmid recovery falls.

The broth after fed-batch culture cannot be sent directly to alkaline lysis; the cells are concentrated by centrifugation or microfiltration (MF-TFF) to remove medium components and then uniformly resuspended in lysis buffer. If resuspension is incomplete, lysis efficiency and plasmid recovery drop.

MakersCytiva, Merck, Repligen, Alfa Laval, Beckman Coulter

Why it is the standard. Disc-stack centrifugation and hollow fiber MF-TFF are standard equipment with a track record in cell harvest and concentration for GMP plasmid manufacturing, removing medium-derived impurities and improving the reproducibility of lysis

Alternatives in practice

  • Batch centrifugal pelleting · Beckman Coulter Avanti JXN-26 / J-26S (4,500–6,000 ×g) — Simple at small to mid scale. Unsuited to continuous processing
  • Tangential flow microfiltration (concentration and washing) · Repligen KrosFlo hollow fiber (0.2/0.45 µm) or Cytiva ReadyToProcess hollow fiber ULTA — Gentle shear; retains the cells while washing out the medium. Flux management is the key

Step 4: Alkaline lysis, neutralization◇ Branches

The key to crude separation that leaves only the plasmid in the supernatant by lysis and neutralization. Excessive handling breaks the supercoils.Debris, protein and gDNA are denatured and precipitated by heat without alkaline denaturation

Standard methodAlkaline lysisA cell suspension pretreated with lysozyme in STET-type buffer (Tris/EDTA/sucrose/Triton X-100) is passed through a heat exchange coil for continuous lysis at about 70–100 °C and cooled rapidly in a cooling coil immediately afterward
EquipmentSingle use static mixerTransfer pumpHeat exchanger (heating coil) + cooling coil, continuous flow by peristaltic pump
ReagentsPlasmid alkaline lysis precipitationLysozyme, STET buffer (Tris, EDTA, sucrose, Triton X-100). NaOH/SDS/potassium acetate for neutralization are not needed
With Thermal lysisA cell suspension pretreated with lysozyme in STET-type buffer (Tris/EDTA/sucrose/Triton X-100) is passed through a heat exchange coil for continuous lysis at about 70–100 °C and cooled rapidly in a cooling coil immediately afterwardWith Alkaline lysis (standard)Alkaline lysis
Details and 3 alternatives

This step coversRelease of plasmid by alkaline lysis and neutralization (alkaline lysis, neutralization)

This is where the bacteria are first broken open and the plasmid inside is taken out. The cells are dissolved with alkali (NaOH and SDS) and the plasmid is released into the liquid.

Neutralizing next with potassium acetate causes the huge genomic DNA, protein and SDS to clump and sink all at once. Only the small circular plasmid remains in the supernatant.

This rough sorting is the key to crude purification. But if too strong, it even breaks the plasmid's 'twist (supercoil),' so how hard it is applied determines quality.

The cells are collected and broken with alkali (NaOH/SDS) to let the plasmid dissolve out. Neutralizing next with potassium acetate causes genomic DNA, protein and SDS to clump and sink, leaving only the small circular plasmid in the supernatant. This step is the key to crude separation, and if overdone, the supercoils are broken.

MakersCytiva, Merck, Pall, Watson-Marlow, Alfa Laval

Why it is the standard. Automated alkaline lysis at industrial GMP scale is standard (Urthaler et al., J Biotechnol 2007). Low-shear continuous lysis suppresses damage to supercoiled forms and shearing of genomic DNA, giving reproducible quality.

Check also. Whether plasmid purification succeeds is in fact decided here. Alkaline lysis is the standard method, inexpensive and able to release the plasmid all at once, but if mixing is too vigorous, genomic DNA is fragmented and can no longer be separated by the later anion exchange, and the supercoiled fraction stalls too. What stumbles most at scale-up is reproducing this 'gentle mixing,' and note that lab hand-feel cannot be scaled up as is.

With Thermal lysis. Strict control of EDTA concentration, residence time and temperature reached is needed to suppress formation of open circular forms

Alternatives in practice

  • Thermal flocculation + solid-liquid separation · Plate heat exchanger + Alfa Laval centrifuge or depth filter — An alternative to chemical lysis that uses no SDS. Suited to automation at large scale
  • Batch alkaline lysis + centrifugation · Stirred tank + Beckman Coulter Avanti centrifuge — For small scale and development. Watch for fragmentation of genomic DNA by shear
  • RNase-free process design · RNA removal is ensured by downstream AEX/HIC (CIMmultus DEAE, etc.) — When GMP policy is to avoid animal-derived/foreign enzymes. Downstream load increases

Step guide

What you actually do

  1. Bring the resuspended cell slurry and the lysis solution (for example 200 mM NaOH + 1% SDS) together in an in-line static mixer
  2. For the time spent passing through the piping (the residence time), keep the cells in contact with the alkali to break them and denature the DNA
  3. Next bring in the neutralization solution (for example 3.0 M potassium acetate, pH 5.5) and lower the pH
  4. Let neutralization solidify and settle the huge genomic DNA, the protein and the SDS, and receive the plasmid-containing fluid together with the white floc

What changes with the conditionWhether it is alkaline lysis with NaOH/SDS and neutralization with potassium acetate, or thermal lysis. In thermal lysis, cell slurry treated with lysozyme in an STET-type buffer is processed continuously at about 70-100 °C and rapidly cooled. There is no alkaline denaturation and no floc forms, SDS and neutralization solution are unnecessary, and debris, protein and genomic DNA are heat-denatured and settle while plasmid and RNA stay in the supernatant. The load of RNA and genomic DNA on the following steps therefore changes

Equipment and materials

Decision points

Batch lysis, or continuous (in-line) lysis?
Continuous lysis allows precise control of the contact time with alkali, and uniformity of mixing and the residence time are the keys to reproducibility. Batch (stirred tank) suits small scale and development, but if mixing is strong the genomic DNA fragments and becomes harder to separate from the plasmid later. The higher the scale, the harder uniform, gentle mixing becomes.
How do you decide the intensity of mixing?
If mixing is too strong the genomic DNA fragments, its properties come closer to those of the plasmid and it becomes hard to separate. If it is too weak, lysis is insufficient and the yield falls. The intensity is set by the type, diameter and number of elements of the mixer and by the flow rate, so vary the conditions at small scale and decide by looking at both the supercoiled content and the genomic DNA remaining.
How do you decide the NaOH concentration and the contact time?
If contact with alkali is long, supercoiled molecules unwind and turn into open circular or linear forms. Concentration, contact time and mixing intensity are conditions decided as one, and are confirmed with your own strain and plasmid. The tolerance on pH is narrow, and the precision of the flow ratio between lysis and neutralization solutions counts.
Alkaline lysis, or thermal lysis?
Thermal lysis passes cell slurry treated with lysozyme in an STET-type buffer through a heat exchanger to lyse it continuously; SDS and neutralization solution are unnecessary and no floating floc forms. In exchange, strict control of the EDTA concentration, the residence time and the temperature reached is needed in order to limit open circular forms.

Common mistakes

  • Raising the mixing intensity to hurry lysis along, so that the genomic DNA is cut finely and becomes hard to separate later
  • Contact with alkali is long, and supercoiled molecules turn into open circular or linear forms
  • Carrying conditions from small-scale manual work (inversion mixing and the like) straight over to agitation in a large tank

Check at your own site

  • At what scale were the measurements that set the alkali contact time and the mixing intensity of your own lysis?
  • When your own lysis conditions are changed, are both supercoiled content and genomic DNA looked at and compared?

Step 5: Clarification, depth filtration◇ Branches

Clarification that removes neutralization aggregates and debris to prevent clogging of the downstream chromatography. Adsorptive retention is avoided by high salt.No floating floc peculiar to alkaline lysis, so the target and the reference method for clarification change

Standard methodDepth filtration → 0.2 µm sterile filtrationHeat-aggregated cell debris, denatured protein and genomic DNA are removed by continuous centrifugation or depth filtration, followed by 0.2 µm sterile filtration
EquipmentDepth filterSterile filter (0.2 µm)Disc-stack centrifuge or depth filter (a special retention system for capturing floating floc is not needed)
ReagentsFiltration-based (no reagents), equilibration/wash buffer (Tris-EDTA system)
With Thermal lysisHeat-aggregated cell debris, denatured protein and genomic DNA are removed by continuous centrifugation or depth filtration, followed by 0.2 µm sterile filtrationWith Alkaline lysis (standard)Depth filtration → 0.2 µm sterile filtration
Details and 3 alternatives

This step coversRemoval of aggregates and cell debris (clarification) (clarification, depth filtration)

On neutralization, genomic DNA, protein and fragments of bacteria float up as a white, cotton-like aggregate. This step removes it to give a clear solution.

The lower layer containing the plasmid is put through depth filtration (straining through a thick filter) and finally sterile filtered at 0.2 µm. The turbidity is eliminated and a clear load solution is prepared.

The aim is to protect the downstream chromatography column. If cloudy liquid is run through, the column clogs, so cleaning up here is a prerequisite for the whole separation.

The white aggregate formed by neutralization (genomic DNA, protein, debris) is removed to give a clear solution. The lower layer containing the plasmid is clarified by depth filtration and the like so that the downstream chromatography column does not clog. Because of the high-salt conditions, adsorptive retention is unlikely to occur, so yield is easy to maintain.

MakersMerck, Sartorius, Repligen, 3M, Alfa Laval

Why it is the standard. In high-salt lysate, adsorptive interactions are masked and depth filtration shows high capacity and high yield (Sigma/Merck technical documents). Scalable for removal of floating aggregates and easy to make single-use.

With Thermal lysis. Handling of the floating floc of carbonate and SDS-potassium precipitate seen in alkaline lysis neutralization is no longer needed, but the load of heat-denatured material may increase

Alternatives in practice

  • Disc-stack centrifugation · Alfa Laval Culturefuge 100 / GEA clarifying centrifuge — Effective for primary removal of high solids. Fine debris requires downstream filtration in combination
  • Tangential flow microfiltration · Repligen KrosFlo hollow fiber (0.45/0.65 µm) — Continuous clarification of lysate. Membrane fouling management is the key
  • Flotation + mesh collection · Dedicated flotation tank configuration — Flotation recovery of SDS precipitate. Reduces centrifuge load for large-scale lysate

Step guide

What you actually do

  1. Receive the neutralized fluid in a hold tank and let the light floc float up and collect in the upper layer
  2. Send the plasmid-containing lower layer to a depth filter to remove the fine floc that remains
  3. Pass it through a 0.2 µm filter to reduce particles and microorganisms
  4. Receive the clarified fluid in a hold bag and send it to the next step

What changes with the conditionWhether it follows alkaline lysis or thermal lysis (with alkaline lysis there is floc that floats up in the neutralization solution, and it is removed by flotation and depth filtration. With thermal lysis there is no such floc, and the heat-denatured cell debris, denatured protein and genomic DNA are removed by continuous centrifugation or depth filtration, where the load of heat-denatured material may be higher)

Decision points

Flotation plus depth filtration, centrifugation, or tangential flow microfiltration?
A common configuration uses the fact that the floc is light and floats readily, letting it float up and then receiving the fluid on a depth filter. Centrifugation suits primary removal of high solids, but for fine debris it has to be combined with filtration afterwards. Microfiltration can clarify continuously, but managing membrane fouling is the key point.
What governs the choice of depth filter grade?
In a high-salt lysate, adsorptive retention is less likely to occur, and depth filtration is said to show high capacity and recovery. Choose the grade (for example the different grades of Millistak+ HC Pro, or 3M Zeta Plus) by measuring plasmid recovery and capacity (L/m²) with the real fluid.
Do you place the 0.2 µm filtration here?
Placing it here lowers the microbial load while protecting the columns and membranes that follow. However, the plasmid is a long molecule and recovery may fall through shear or adsorption, so measure the recovery and decide where to place it.
How does the lysis approach change what clarification has to remove?
Alkaline lysis removes the floc that floats up, whereas thermal lysis has no such floc and what has to be removed is the heat-denatured cell debris, denatured protein and genomic DNA. The load of heat-denatured material may be higher.

Common mistakes

  • Running the whole volume onto the depth filter without waiting for the floc to float up, so that it fouls in a short time
  • Deciding the filter area from a lot in good condition, so that a lot with a lot of floc fouls it
  • Genomic DNA made fine by the intensity of lysis is not removed by filtration and is carried into the following steps

Check at your own site

  • Is your own depth filter area decided from measurements on the lot with the most floc?
  • From which downstream condition was your own turbidity target for the clarified fluid worked back?

Purification(5 steps)

Step 6: UF/DF, concentration

Pretreatment that concentrates the dilute liquid and exchanges the buffer to suit chromatography, raising capture loading and robustness.Pretreatment that concentrates the dilute liquid and exchanges the buffer to suit chromatography, raising capture loading and robustness.

Standard methodUltrafiltration/diafiltration (UF/DF, 100–300 kDa membrane)Ultrafiltration/diafiltration (UF/DF, 100–300 kDa membrane)
Details and 3 alternatives

This step coversConcentration and pretreatment by TFF (conditioning before chromatography) (UF/DF, concentration)

The clarified liquid is 'dilute and large in volume.' Loading it as is onto the purification column is inefficient, so first water is removed by ultrafiltration (UF/DF) to concentrate it.

The membrane acts as a mesh that does not pass the large plasmid and passes only salts and small molecules. Using this, the buffer is replaced with one whose composition, such as salt concentration, suits chromatography.

It is, so to speak, conditioning before the main event. With concentration and composition set, more can be loaded at once on the next capture chromatography, and the separation also tends to be stable.

The clarified liquid is dilute and large in volume, so it is concentrated by ultrafiltration (TFF) and the salt concentration and so on are exchanged into a buffer suited to chromatography. Plasmid molecules are large, so they are retained on the membrane while salts and small molecules are removed. It is pretreatment that raises the loading amount and robustness of the next capture chromatography.

MakersCytiva, Sartorius, Repligen

Why it is the standard. Standard adoption for concentration and buffer exchange before chromatography in large-scale pDNA platforms (CDMO process descriptions such as Catalent/Anemocyte). Management of membrane shear achieves both maintaining supercoiling and high recovery.

Alternatives in practice

  • Selective salt precipitation (isopropanol/PEG) · Stirred tank + Beckman centrifuge or depth filter — Combines concentration and crude purification. Solvent recovery and waste treatment are challenges
  • Hollow fiber TFF (large pore size) · Repligen KrosFlo hollow fiber (500 kDa to 0.05 µm) — Reduces shear on large plasmids. Balance between flux and genomic DNA permeation
  • Concentration by bind-elute chromatography · Sartorius CIMmultus DEAE monolith — Concentrates by capture without going through TFF. Buffer exchange is achieved at the same time

Step guide

What you actually do

  1. Receive the clarified fluid in the reservoir of the TFF (tangential flow filtration) system
  2. Circulate the fluid along the surface of a membrane of around 100-300 kDa (for example) and concentrate it by letting water, salts and small molecules pass out through the membrane (UF)
  3. Add a buffer close to the equilibration buffer of the AEX that follows (for example 50 mM Tris-HCl, about 0.5 M NaCl, pH 8.0) and exchange the fluid into that buffer (diafiltration, DF)
  4. Hold the crossflow rate and the transmembrane pressure (TMP) down to keep shear low
  5. Recover the concentrated fluid and receive it in a hold bag

Decision points

UF/DF, selective salt precipitation, or concentration by bind-and-elute chromatography?
UF/DF is the common configuration, doing concentration and buffer exchange at once. Salt precipitation with isopropanol or PEG can serve as both concentration and coarse purification, but solvent recovery and waste treatment are issues. Concentrating by bind-and-elute chromatography (DEAE monoliths and the like) also achieves buffer exchange at the same time, without going through TFF.
What governs the choice of membrane pore size and format?
The plasmid is a large molecule and stays on the membrane while salts and small molecules pass. A large-pore hollow fiber membrane (for example 500 kDa to 0.05 µm) can reduce shear on large plasmids, but the balance between flux and passage of genomic DNA has to be looked at. Choose by measuring plasmid recovery and supercoiled content with the real fluid.
How do you hold down shear?
The plasmid is a long chain molecule and its supercoils are readily broken by shear from pumps and the membrane surface, so hold down the crossflow rate and the transmembrane pressure. Avoid designs that raise the flow rate to gain flux; the fitting approach is to increase the area and keep the flow rate low.
What do you match the DF buffer to?
Match it to the binding conditions (conductivity and pH) of the AEX that follows. Decide the conditions by confirming plasmid binding with the real fluid, and measure and record the conductivity after DF.

Common mistakes

  • Raising the circulation flow rate to shorten the time, so that supercoiled molecules are broken by shear
  • The membrane pore size does not fit, so either the nucleic acid fragments to be removed stay on the membrane or the plasmid is lost
  • Deciding the DF buffer before deciding the AEX conditions, and learning of poor binding at the next step

Check at your own site

  • Were your own TFF flow rate and transmembrane pressure decided by watching the change in supercoiled content?
  • Was your own conductivity after DF worked back from the AEX binding conditions?

Step 7: Precipitation, conditioning◇ Branches

Direct loading of clarified lysate onto AEX fails from too many impurities, so prior precipitation is essentialBecause gDNA is removed by heat precipitation at the lysis stage, the load profile of the later selective precipitation changes

Standard methodCalcium chlorideCalcium chloride
With Thermal lysisBecause gDNA is removed by heat precipitation at the lysis stage, the load profile of the later selective precipitation changesWith Alkaline lysis (standard)Calcium chloride
Details and 2 alternatives

This step coversSelective precipitation of high-molecular-weight RNA and genomic DNA and adjustment of loading conditions for anion exchange → CaCl2/high-salt precipitation and conditioning (precipitation, conditioning)

In a process that does not degrade RNA with an enzyme (RNase-independent), the clarified liquid still contains large amounts of high-molecular-weight RNA, genomic DNA and endotoxin.

So calcium chloride or high salt is used to selectively sink and drop these troublemakers. It also serves as preliminary handling that conditions to a salt concentration and conductivity suited to the subsequent anion exchange.

Why is it needed? If these are loaded in excess onto the next column, both the capacity to adsorb and the resolution break down. It is an unglamorous but effective step that sets the loading conditions.

In an RNase-independent process, if the clarified lysate is applied directly to anion exchange, excess high-molecular-weight RNA, genomic DNA and endotoxin break down the column capacity and resolution. Removing these by selective precipitation with CaCl2 or high salt and conditioning to a salt concentration and conductivity suited to the subsequent AEX capture is a standard step.

MakersCytiva, Merck, Thermo Fisher

Why it is the standard. CaCl2 precipitation + Millistak+ depth filtration is a proven method widely adopted for RNA removal and AEX pretreatment in GMP plasmid manufacturing without RNase

Check also. This selective precipitation step is needed when the process is designed not to use an enzyme that degrades RNA (RNase). It is effective for policies that avoid animal-derived or foreign enzymes, but if the design uses an enzyme, the whole step may become unnecessary. Treat it as a step whose necessity changes with the company's own process policy.

With Thermal lysis. In thermal lysis, high-molecular-weight RNA is the main residual nucleic acid, so calcium chloride selective precipitation is optimized for RNA removal, and conditions are set on the premise that the gDNA load has already been reduced at the lysis stage

Alternatives in practice

  • RNA and gDNA removal by sequential PEG/CaCl2 precipitation · Stirred tank + Beckman centrifuge / depth filter — Selective precipitation of high-molecular-weight nucleic acids. Trade-off between recovery and purity
  • Pre-reduction of endotoxin by Triton X-114 phase separation · Temperature-controlled stirred tank (cloud point separation) — Reduces LPS load before AEX. A step to remove residual detergent is needed

Step guide

What you actually do

  1. Add calcium chloride (CaCl₂) or a high-salt buffer to the clarified, concentrated fluid and stir, precipitating high molecular weight RNA, genomic DNA and part of the endotoxin
  2. Remove the precipitate with a depth filter
  3. Add buffer to the filtrate in line to dilute it and adjust it to the salt concentration (conductivity) and pH that suit AEX binding
  4. Measure conductivity and pH and record the conditions of the load

What changes with the conditionAfter alkaline lysis both genomic DNA and RNA remain, so the precipitation targets both. After thermal lysis the genomic DNA is heat-precipitated and removed at the lysis stage and high molecular weight RNA becomes the main residual nucleic acid, so the CaCl₂ precipitation conditions are decided for RNA removal and the design assumes that the genomic DNA load has already fallen at the lysis stage

Decision points

Use RNase, or remove by precipitation?
In a process that does not rely on RNase, running the clarified fluid straight onto AEX leaves excess high molecular weight RNA, genomic DNA and endotoxin, so that column capacity and resolution are not sufficient. A configuration that removes them by precipitation beforehand is used. A design that adds RNase brings additional confirmation of the residual enzyme.
How do you decide the precipitation conditions (CaCl₂ concentration, time, temperature)?
The effect of removing RNA and the loss of recovery through co-precipitation of plasmid are in a relationship where gaining one lowers the other. There are also options that shift the balance of recovery and purity, such as sequential precipitation with PEG and CaCl₂. Vary the conditions at small scale and choose on both the RNA remaining and the plasmid recovery.
Do you reduce endotoxin beforehand here?
Phase separation with Triton X-114 (separation across the cloud point) can reduce the endotoxin load ahead of AEX, but a step to remove the residual detergent afterwards is needed.
In-line dilution, or a pre-dilution tank?
The precision of the conductivity adjustment depends on the pump ratio and the calibration of the conductivity meter. In-line dilution keeps the fluid volume and the number of tanks down, while pre-dilution is simpler. Keep the calibration of the conductivity and pH sensors in the operating records.

Common mistakes

  • Not varying the precipitation conditions, so that plasmid co-precipitates as well and recovery falls
  • Not confirming downstream what remains of the reagents used for precipitation (Ca²⁺ and the like), and carrying them over
  • Relying on the pump ratio alone for the conductivity adjustment, without confirming the calibration of the conductivity meter

Check at your own site

  • Were your own precipitation conditions decided by looking at both RNA removal and plasmid recovery?
  • With which instrument is the conductivity of your own AEX load measured, and how often is it calibrated?

Step 8: Capture / anion exchange

The first chromatography, which captures plasmid by its strong negative charge and removes HCP, RNA and genomic DNA greatly in a single step.The first chromatography, which captures plasmid by its strong negative charge and removes HCP, RNA and genomic DNA greatly in a single step.

Standard methodAnion exchange chromatography (AEX, salt gradient elution)Anion exchange chromatography (AEX, salt gradient elution)
Details and 3 alternatives

This step coversCapture by anion exchange and removal of HCP, RNA and genomic DNA (capture/anion exchange)

Plasmid has a strongly negative charge on its backbone. So it is adsorbed like a magnet onto a positively charged support (anion exchange), capturing the product all at once.

After capture, it is eluted by raising the salt concentration. In this single step, the major impurities such as host-derived protein, RNA and genomic DNA are all greatly stripped away together.

Plasmid molecules are large, so monolith or membrane type supports that let them reach the interior are preferred. It is a core step that performs capture, concentration and impurity removal at the same time.

Plasmid is strongly negatively charged, so it is captured by strongly adsorbing it to a positive support (anion exchange) and eluting by raising the salt concentration. This single step greatly removes the major impurities such as host-derived protein, RNA and genomic DNA, and concentrates and captures the product. Monoliths and membranes that large plasmids can easily enter are used.

MakersCytiva, Merck, Sartorius, Pall, Thermo Fisher

Why it is the standard. Convection-based monoliths (6 µm channels) and membranes avoid pressure drop and exclusion of large plasmids and achieve high yield and high purity (Sartorius BIA Separations). AEX is the representative first chromatography for pDNA capture.

Check also. Plasmids are large molecules, and with ordinary bead resins they may not enter the pores and binding capacity may not develop. For large plasmids, monolith or membrane supports are suitable, but the resolving power for isoforms (open circular, linear, etc.) is limited with this single step alone, so confirmation by polishing chromatography and quality testing is presupposed.

Alternatives in practice

  • Bead-based AEX resin (large pore) · Cytiva Capto DEAE / Capto Q ImpRes、Tosoh TOYOPEARL GigaCap Q-650M — High capacity and low cost, but the dynamic binding capacity is rather low because plasmid is limited in diffusion into the pores
  • SEC as the primary separation · Cytiva Sepharose 6 Fast Flow / Sephacryl S-1000 SF — Separation is possible without adding salt, but throughput and concentration are limited
  • Membrane AEX · Pall Mustang Q (0.8 µm pores)/Sartorius Sartobind Q — High flow rate and disposable, with high binding capacity for large nucleic acids. Lower resolution than resin

Step guide

What you actually do

  1. Equilibrate the AEX monolith column (DEAE or QA) or membrane with equilibration buffer (for example 50 mM Tris-HCl, about 0.5 M NaCl, pH 8.0)
  2. Run the load and adsorb the plasmid onto the matrix (protein and part of the RNA pass through)
  3. Wash with the same buffer as the equilibration to flush out loosely bound impurities
  4. Elute with a rising salt gradient (for example up to 1.0 M NaCl) and fractionate and collect the plasmid peak

Decision points

Is the matrix a monolith, a membrane, or a bead resin?
Monoliths and membranes, through which the fluid flows convectively, let large plasmids in readily and avoid pressure drop and exclusion. Large-pore bead resins (for example Capto DEAE, GigaCap Q-650M) offer large volumes at low cost, but their plasmid binding capacity is on the low side because of diffusion constraints into the pores. Membranes can be used at high flow rates and disposed of, but their resolution is lower than resins.
What decides the channel size of a monolith?
It is decided by the size of the plasmid and by the carryover of open circular forms. The maker's guidance gives 2 µm channels for below 8 kbp and 6 µm above 8 kbp as examples. Where open circular forms are carried over, smaller channels foul more readily, while enlarging the channels lowers the binding capacity; in research too, there is a report that a 3 µm column was not optimal above about 7 kbp and 6 µm was recommended.
How do you estimate the binding capacity?
Catalog dynamic binding capacities (DBC) are mostly values measured with protein. The plasmid is a far larger molecule than a protein, and on the same resin the actual capacity is much lower than the catalog figure. Fix the flow rate and measure it with your own plasmid (size and supercoiled content).
Do you elute with a gradient or with a step?
Plasmid, RNA, genomic DNA and endotoxin differ in the strength of their negative charge, and their elution positions shift along a salt gradient. One option is to investigate the separation with a gradient and then use a step in routine operation. Binding and elution depend strongly on conductivity, so control the buffers with a conductivity meter.

Common mistakes

  • Deciding the load from the catalog binding capacity (a value measured with protein), which is not enough for plasmid
  • The conductivity of the buffer drifts, changing the positions of binding and elution
  • Choosing a channel size or pore size that does not suit the plasmid size, so that pressure rises or the plasmid does not bind

Check at your own site

  • Was your own AEX load decided from a binding capacity measured with plasmid DNA?
  • When the conductivity of your own AEX buffer drifts, how is that detected and how is it handled?

Step 9: Polishing / hydrophobic interaction

A finishing step that removes open circular and linear isoforms and endotoxin and contributes to meeting the supercoiled fraction specification.A finishing step that removes open circular and linear isoforms and endotoxin and contributes to meeting the supercoiled fraction specification.

Standard methodHydrophobic interaction chromatography (HIC, high-salt adsorption / low-salt elution)Hydrophobic interaction chromatography (HIC, high-salt adsorption / low-salt elution)
Details and 3 alternatives

This step coversIsoform separation and endotoxin removal by hydrophobic interaction (polishing/hydrophobic interaction)

Even after capture, unwound open circular and cut linear plasmids still remain, along with endotoxin, which causes fever. This is the finishing step that removes them.

The difference in 'reluctance to mix with water (hydrophobicity)' is used. Adsorbing onto the support at high salt concentration and eluting while lowering the salt separates and removes these impure forms.

The aim is to concentrate at high purity only the twisted form (supercoiled form) desirable for therapy. It is a core step that contributes to meeting the supercoiled fraction specification.

A finishing step that removes the open circular and linear plasmids that remain after capture, and endotoxin. When adsorbed onto a hydrophobic support under high salt, these impure isoforms and endotoxin can be separated, and the supercoiled form desirable for therapy can be concentrated at high purity. A core step that contributes to meeting the supercoiled fraction specification.

MakersCytiva, Merck, Sartorius, Thermo Fisher

Why it is the standard. HIC is the representative polish that removes open circular and linear isoforms and endotoxin and concentrates the supercoiled form (US patent 7169917, Sartorius pDNA process). The two-stage AEX → HIC is a widely adopted configuration for pDNA purification.

Check also. Hydrophobic interaction chromatography adsorbs at a high salt concentration (ammonium sulfate, etc.), so behind it lie the cost of handling large amounts of salt and the effort of buffer design. The ability to separate the supercoiled form from impure isoforms depends on salt type, concentration and conditions, so conditions must be worked out for each product.

Alternatives in practice

  • Endotoxin removal by Triton X-114/X-100 phase separation · Temperature-controlled stirred tank (cloud point separation) — Removes LPS efficiently. Management of residual detergent is needed
  • Supercoil-selective polishing by thiophilic aromatic adsorption · Cytiva PlasmidSelect Xtra (28-4024-02) — Separates sc from oc/linear with high resolution. Uses high-salt ammonium sulfate conditions
  • Polishing by a second-stage AEX · Sartorius CIMmultus QA monolith / Cytiva Capto Q ImpRes — An alternative when HIC is to be avoided. Isoform resolving power is inferior to HIC/thiophilic

Step guide

What you actually do

  1. Add high salt (for example 1.5-2.5 M ammonium sulfate) to the AEX eluate to bring it to the HIC adsorption conditions
  2. Run it onto the HIC monolith (for example C4) and adsorb the plasmid, its isoforms and the endotoxin
  3. Elute while lowering the salt and collect the supercoiled fraction. The open circular and linear forms and the endotoxin separate into different fractions
  4. Measure the supercoiled content (CGE) and the endotoxin fraction by fraction and decide the range to collect

Decision points

Include HIC, or use AEX alone?
AEX alone cannot fully remove genomic DNA, RNA and open circular forms, and a configuration that adds HIC is widely used, because simply raising and lowering the salt concentration drives out the isoforms and the endotoxin together. Behind that lie the cost of handling large amounts of salt and the effort of buffer design. Decide whether to include it by working back from the supercoiled content and endotoxin specifications.
Where do you cut the fractions?
The wider you cut on the open circular side in order to raise the supercoiled content, the lower the recovery. Decide the balance between the target supercoiled content and recovery by setting the measured values for each fraction side by side.
On what do you compare matrices?
Compare on the hydrophobicity of the ligand and on the particle size (or channel size), not on binding capacity figures. Adsorption that is too strong cannot be eluted, and adsorption that is too weak gives no separation. The salt species (ammonium sulfate and the like), its concentration and the temperature are also part of the conditions.
Are there options for reducing the salt?
There are low-salt ligands, HIC membranes and mixed-mode matrices. Waste and the effort of desalting are reduced, but you give up part of the orthogonality that came from applying ion exchange and HIC separately. Thiophilic adsorption (PlasmidSelect Xtra and the like) and a second AEX step are also candidate alternatives.

Common mistakes

  • Not looking at the temperature dependence of adsorption with salt, so that the elution position shifts with the difference in room temperature between the laboratory and the manufacturing room
  • Taking wide fractions to gain recovery, and failing to meet the supercoiled content specification
  • Choosing the matrix from the binding capacity table alone, without looking at ligand strength and particle size

Check at your own site

  • In cutting your own HIC fractions, which did you give priority to, supercoiled content or recovery?
  • Do your own high-salt adsorption conditions include temperature among the controlled conditions?

Step 10: Final polishing, desalting

Final polishing that separates open circular forms, aggregates and fragments by SEC after HIC to secure an SC content of 90% or moreFinal polishing that separates open circular forms, aggregates and fragments by SEC after HIC to secure an SC content of 90% or more

Standard methodFinal polishing and desalting by size exclusion chromatography using Sepharose 6 Fast FlowFinal polishing and desalting by size exclusion chromatography using Sepharose 6 Fast Flow
Details and 2 alternatives

This step coversFinal polishing and buffer exchange by size exclusion → separation of supercoiled monomer and removal of aggregates/degradation products (final polishing, desalting)

The final polishing of purification. Sorting only by differences in molecular size, it separates open circular, linear and multimeric forms and small fragments that the earlier steps could not completely remove.

Size exclusion chromatography is used. Using the property that larger molecules elute earlier and smaller ones later, the supercoiled form desirable for therapy is raised to 90% or more.

The advantage is that desalting and buffer exchange can be done at the same time. It is the standard closing step of plasmid purification that finishes purity while bridging to the next formulation.

Open circular, linear, multimeric and low-molecular-weight fragments that anion exchange and HIC cannot completely remove are separated by size exclusion chromatography to achieve the supercoiled content of 90% or more required by regulation. It also serves for desalting and buffer exchange at the same time, and is the standard final polishing step of pDNA purification.

MakersCytiva, Sartorius

Why it is the standard. Sepharose 6 FF is a large-pore gel filtration support with a track record, widely used in the final SEC polishing of pDNA purification for separation of the supercoiled monomer and buffer exchange

Alternatives in practice

  • Size-exclusion-like polishing with monolith supports · Sartorius CIM/CIMmultus monolith — Avoids diffusion limitation for large plasmids and allows high flow rates. The separation mechanism differs from pure SEC
  • Gel filtration polishing with Sephacryl S-1000 SF · Cytiva Sephacryl S-1000 SF + AxiChrom / XK columns — Wide fractionation range for very large nucleic acids. Advantageous for plasmids larger than those suited to Sepharose 6 FF

Formulation and fill-finish(1 step)

Step 11: Final filtration, fill-finish

The final step that exchanges into storage buffer, adjusts to the specified concentration, and decides stability and sterility by sterile filtration and filling.The final step that exchanges into storage buffer, adjusts to the specified concentration, and decides stability and sterility by sterile filtration and filling.

Standard methodFinal formulation buffer exchange and concentration adjustment by UF/DF → 0.2 µm sterile filtration → aseptic fillingFinal formulation buffer exchange and concentration adjustment by UF/DF → 0.2 µm sterile filtration → aseptic filling
Details and 3 alternatives

This step coversFinal buffer exchange, concentration adjustment, and sterile filtration and filling (final filtration, fill-finish)

A step that readies the fully purified plasmid in a form suited to storage and administration. UF/DF replaces it into a buffer such as PBS or TE and matches it exactly to the specified concentration.

Finally it is sterile filtered at 0.2 µm to cut off microorganisms and aseptically filled into vials. The final 'form' as drug substance/drug product is decided here.

Solution stability and sterility are also settled at this stage. Because it becomes the form that reaches patients as an injectable nucleic acid therapeutic, it is an important step that determines how well the formulation turns out.

The purified plasmid is replaced into a buffer suited to storage (such as PBS or TE) and adjusted to the specified concentration. Finally it is sterile filtered at 0.2 µm and aseptically filled into vials. Solution stability and sterility are decided here, and the form as drug substance/drug product is established.

MakersCytiva, Sartorius, SP Scientific, Thermo Fisher, IMA

Why it is the standard. For pDNA platforms, the standard final steps are UF/DF → 0.2 µm filtration → dispensing (Catalent/Anemocyte, etc.). The drug substance is generally prepared at a concentration of several mg/mL and aseptically filled into vials.

Check also. pDNA drug substance is generally sterile filtered and dispensed, then filled into single-use bags/bottles, stored and transported frozen (−20 to −80 °C), and handed to later steps (LNP encapsulation, dilution, etc.).

Alternatives in practice

  • Lyophilization (naked DNA formulation) · SP Scientific LyoStar / IMA Edwards freeze dryers — Improves room-temperature stability. Requires a lyoprotectant and process development
  • Lipid nanoparticle (LNP) encapsulation · Precision NanoSystems NanoAssemblr (microfluidic) — Formulation for in vivo delivery. Control of particle size and encapsulation efficiency is the key
  • Frozen bulk storage (−20/−80 °C) · Sartorius Celsius FFT / Cytiva bio-containers + ultra-low temperature freezers — Simplest and stable. Cold-chain management during transport and thawing is needed

Quality attributes and analytics(9 steps)

Step 12: Supercoiled content analysis

Measuring %SC, which affects potency and transfection efficiency, the most important CQA. Roughly 80% or more is the specification guide.Measuring %SC, which affects potency and transfection efficiency, the most important CQA. Roughly 80% or more is the specification guide.

Standard methodIsoform quantitation by capillary gel electrophoresis (CGE)Isoform quantitation by capillary gel electrophoresis (CGE)
ReagentsSCIEX DNA 20 kb Plasmid and Linear Kit (separation of sc/oc/linear, 2,000–19,000 bp) or SCIEX dsDNA 1000 Kit, gel sieving buffer + intercalating dye
Details and 3 alternatives

This step coversHomogeneity = supercoiled content (%SC) (supercoiled content analysis)

Plasmid has 3 forms: the twisted form (supercoiled), the unwound open circular form and the cut linear form. The supercoiled form is what works therapeutically.

The proportion (%SC) is counted accurately by capillary gel electrophoresis, an electrophoresis method using a thin tube. It is a test that cleanly separates the 3 forms and gives the ratio.

Why is it the most important? Because the supercoiled fraction is directly tied to efficacy and ease of entry into cells. The FDA has also recommended specifying roughly 80% or more as a guide.

Plasmid has 3 forms: supercoiled, open circular and linear, and the supercoiled form is desirable for therapy. Its proportion (%SC) affects potency and transfection efficiency, so it is measured as the most important CQA. The FDA has recommended specifying it with roughly 80% or more as a guide.

MakersBio-Rad, Agilent, SCIEX, Thermo Fisher

Why it is the standard. CGE can separate and quantify SC/OC/linear with high resolution, linear response and high reproducibility, and is superior to classical agarose gel (PMID 35733006, Sci Rep 2025). %SC is a representative homogeneity indicator related to potency and safety.

Check also. The specification value for %SC (supercoiled content) varies by project and authority, and it is generally organized with roughly 80% or more as a guide, but some designs require higher levels (such as 90% or more). Capillary gel electrophoresis, with high resolution, is advantageous as the final reference, but simple agarose gels are inferior in resolution and quantitative accuracy, so the specification should not be fixed too rigidly to a single value or a single method.

Alternatives in practice

  • Neutral agarose gel electrophoresis + densitometry · Bio-Rad PowerPac+GelDoc Go, Image Lab analysis — Simple and low-cost, but resolution and quantitative accuracy are inferior to CGE
  • AEX-HPLC · Agilent 1290 Infinity II Bio LC + Thermo Fisher DNAPac PA200 column — Quantifies isoforms by HPLC. Easy to share equipment
  • Alkaline agarose gel electrophoresis (AAGE) · Bio-Rad submarine electrophoresis system — Useful for detecting single-strand breaks (nicks). Complementary to neutral gels

Step guide

What you actually do

  1. Dilute the sample with buffer and inject it, by applying voltage, into a capillary filled with gel sieving buffer and a fluorescent dye (an intercalator)
  2. Run a separation in which the 3 forms (supercoiled, open circular, linear) resolve by differences in size and shape (for example the SCIEX DNA 20 kb Plasmid and Linear Kit, 2,000-19,000 bp)
  3. Obtain the area of each peak from the fluorescence or UV signal
  4. Calculate the proportion of supercoiled material in the total of all peaks (%SC) and record it for each lot

Decision points

Is the method CGE, an agarose gel, or AEX-HPLC?
CGE can resolve supercoiled, open circular and linear forms with high resolution, a linear response and good reproducibility, and is said to suit quantitation better than a classical agarose gel. Agarose gels are simple and low-cost but inferior in resolution and quantitative precision. AEX-HPLC can share instruments easily, and alkaline agarose gels can be used to detect single-strand breaks (nicks), complementing neutral gels.
How do you set the specification value?
The %SC specification is decided by the use and the filing. The FDA guidance on plasmid DNA vaccines for infectious diseases (2007) states that above 80% is desirable, and while some sources draw the line using this as a reference, others say that 90% or more is often targeted. Set your own specification by working back from the requirements of the downstream modality (AAV, lentivirus, mRNA).
What do you do when you change the measurement method?
Because this is a method-dependent attribute, write the measurement method as well as the figure into the specification and, when changing it, take data from measuring the same sample by both methods and setting them against each other. Without that, the values of past lots and the values from the new method are not on the same footing.
How do you decide the handling of samples?
Vigorous agitation, freeze-thaw and the dilution history can break supercoils. Fix the sample handling in the procedure so that manufacturing variation can be separated from differences in sample handling.

Common mistakes

  • Setting %SC values from the literature or other companies, measured by different methods, side by side as they are
  • Supercoils break through sample handling (vigorous agitation, freeze-thaw) and this is mistaken for a manufacturing problem
  • Having no bridging data when the measurement method was changed, so that there is no link to past lots

Check at your own site

  • From the requirements of which downstream use was your own %SC specification worked back?
  • By which method was your own %SC value measured, and when the method was changed was the same sample measured by both?

Step 13: Identity confirmation

Assure every lot has the designed sequence and structure, ruling out mix-ups and mutations, the fundamental test for nucleic acid therapeutics.Assure every lot has the designed sequence and structure, ruling out mix-ups and mutations, the fundamental test for nucleic acid therapeutics.

Standard methodRestriction enzyme digestion mapping + sequence confirmation (Sanger or whole-plasmid sequencing)Restriction enzyme digestion mapping + sequence confirmation (Sanger or whole-plasmid sequencing)
Details and 3 alternatives

This step coversConfirmation of identity (identity confirmation)

A test that confirms every time, lot by lot, whether the plasmid to be shipped has 'the correct sequence and structure as designed.' It assures there are no mix-ups or mutations.

It is a 2-stage approach. The band pattern after restriction enzyme digestion shows the rough structure, and sequencing checks the sequence letter by letter, confirming agreement with the design.

For therapeutic nucleic acids, this identity is the foundation. If the contents differ, efficacy and safety both collapse from the ground up, so confirmation for every lot is indispensable.

Confirm for every lot that the plasmid to be shipped has 'the correct sequence and structure as designed.' The band pattern after restriction enzyme digestion and sequence verification by sequencing show that there are no mix-ups or mutations. Identity assurance that is the foundation of therapeutic nucleic acids.

MakersBio-Rad, Agilent, SCIEX, Illumina, Thermo Fisher

Why it is the standard. Confirmation of sequence identity is a mandatory requirement in gene and cell therapy CMC (EMA gene transfer guideline, Ph.Eur 5.14). The combination of restriction map + sequencing is a widely adopted identity test.

Alternatives in practice

  • NGS full-length sequence confirmation · Illumina MiSeq or Oxford Nanopore MinION — Confirms the whole-plasmid sequence with high reliability. Also detects minor mutations and rearrangements
  • Restriction enzyme fingerprinting alone · Agilent 5200 Fragment Analyzer / Bio-Rad agarose gel — Rapid, low-cost identity confirmation. Cannot assure at the sequence level
  • Confirmation of target sequence by PCR/qPCR · Thermo Fisher QuantStudio 5 / Applied Biosystems 7500 — Specialized for confirming the presence of a specific region (such as the transgene). Full-length assurance is needed separately

Step guide

What you actually do

  1. Cut the plasmid with restriction enzymes, examine the fragment length pattern by electrophoresis and compare it with the fragments predicted from the design
  2. Read the sequence on a sequencer (several Sanger primers, or whole-circle sequencing) and match it against the design sequence
  3. Record the result of the match (whether it agrees or there are differences)
  4. The presence of particular regions, such as the transgene, is sometimes also confirmed by PCR

Decision points

Is the restriction pattern enough, or do you read the sequence as well?
Restriction patterns are quick and low-cost but cannot give assurance at the sequence level. For the quality of gene and cell therapies, confirmation of the sequence identity of the plasmid is required, and a combination of the restriction map and sequencing is widely used.
Read the whole circle for every lot, or read the whole circle at the bank and only part of it for each lot?
How much of this is made lot release testing changes with the filing category and the decision of the quality unit. Decide, together with risk assessment, whether whole-circle reading is done for every lot or at the bank stage, with restriction patterns and partial sequence for each lot.
Sanger or next-generation sequencing?
Sanger is widely used for identity confirmation, but because of the read length constraint several primers are needed to cover the whole circle. Next-generation sequencing (including whole-circle nanopore reading) can detect minute mutations and rearrangements as well, but an analysis pipeline is needed.
Do you use PCR to confirm particular regions?
PCR or qPCR is quicker for confirming the presence of particular regions such as the transgene, but assurance of the full length is needed separately.

Common mistakes

  • Judging from the restriction pattern alone that the sequence is the same
  • Recording that the whole circle was confirmed when, because of the read length constraint, a region containing repeat sequences has not been read through
  • Misreading the pattern without noticing incomplete digestion by the enzyme

Check at your own site

  • Does your own identity test read the sequence around the whole circle? For every lot?
  • Is your own restriction pattern a procedure that compares against the fragments predicted from the design?

Step 14: Content, purity / UV measurement

Item for dose design and primary purity judgment: quantify concentration and assess protein contamination by the 260/280 ratio.Item for dose design and primary purity judgment: quantify concentration and assess protein contamination by the 260/280 ratio.

Standard methodUltraviolet absorption spectroscopy (UV, quantitation by A260, purity evaluation by A260/280 and A260/230)Ultraviolet absorption spectroscopy (UV, quantitation by A260, purity evaluation by A260/280 and A260/230)
ReagentsDilution buffer (TE: 10 mM Tris-1 mM EDTA, or PBS), blank sample
Details and 3 alternatives

This step coversContent and purity (concentration and A260/280 ratio) (content, purity/UV measurement)

A basic test that measures 'how much is in it (concentration)' and 'how pure it is' by how light is absorbed. The amount of plasmid is obtained from absorbance at 260 nm.

Purity is seen by the A260/280 ratio. For pure double-stranded DNA, 260/280 is about 1.8 and 260/230 about 2.0 as a guide. Contamination with protein or organic matter shifts these values.

A step of a yardstick, so to speak, that provides the basis for deciding the dose. Because it can be measured easily, it is also routinely used as primary screening of purity.

Measure the amount (concentration) of plasmid and the A260/280 ratio, which indicates low protein contamination. For pure double-stranded DNA, 260/280 of about 1.8 and 260/230 of about 2.0 are the guide. It is the basis for dose design and also serves as the primary screening of purity.

MakersAgilent, SCIEX, Thermo Fisher

Why it is the standard. dsDNA quantitation by A260 and purity judgment by A260/280 and A260/230 are the standard of nucleic acid quantitation (QIAGEN/Addgene technical documents). Simple and nondestructive, widely used in lot release.

Check also. UV absorbance (A260) does not distinguish double-stranded DNA from RNA and single-stranded nucleic acids, so residual RNA overestimates concentration and also makes the A260/280 ratio look better than it is. Because it is primary data that affects dose design, it is safer to read it together with confirmation by other principles such as fluorescent dye methods (double-stranded DNA specific) and capillary electrophoresis.

Alternatives in practice

  • Fluorescent dye method (dsDNA-specific) · Thermo Fisher Quant-iT PicoGreen dsDNA Assay Kit (P7589) + Qubit 4 / microplate reader — Quantifies dsDNA with high sensitivity without interference from RNA/ssDNA. Purity evaluation is separate
  • Purity and content by AEX-HPLC/CGE · Agilent 1290 Infinity II Bio LC + DNAPac PA200, SCIEX PA 800 Plus — Evaluates purity and isoforms at the same time. Calibration and standards are required
  • Absolute quantitation of specific sequences by qPCR · Thermo Fisher QuantStudio 5 — Absolutely quantifies the target copy number. A different indicator from total DNA amount

Step guide

What you actually do

  1. Dilute the sample with dilution buffer (TE or PBS) and measure a blank with the same buffer
  2. Measure the absorbance at 260, 280 and 230 nm on a UV-Vis spectrophotometer (microvolume or quartz cuvette)
  3. Calculate the double-stranded DNA concentration from A260 (an absorbance of 1 in a 1 cm path length cuvette is roughly 50 µg/mL)
  4. Look at the A260/A280 ratio (about 1.8 for pure double-stranded DNA) and the A260/A230 ratio (about 2.0)

Decision points

Is UV enough, or a fluorescent dye, HPLC/CGE, or qPCR?
UV is simple and non-destructive, but it also picks up RNA, nucleotides and single strands, so it is an indicator of total nucleic acid. Fluorescent dyes (PicoGreen and the like) can quantify double-stranded DNA specifically and are less subject to interference from RNA and ssDNA, but purity is assessed separately. AEX-HPLC and CGE can look at purity and the isoforms at the same time. qPCR gives the copy number of a particular sequence, which is a different indicator from the total DNA quantity.
Can the A260/A280 ratio be used as proof of purity?
The ratio moves with the pH of the solution and the water used for dilution. For RNA measurements, there is a report that the ratio was around 1.5 when measured in water and rose to around 2.0 when measured in water adjusted to slightly alkaline. The ratio is a sieve for seeing the tendency of contaminants and cannot be used as proof of purity, so fix the pH and conditions of the diluent and read it together with the other purity tests.
How do you set the concentration specification and its tolerance?
Because it is the basis for calculating the amount of DNA used downstream (the amount of DNA added for transfection, the amount of template for IVT), decide the tolerance from how it is used downstream.
Microvolume or a quartz cuvette?
If the sample volume is small, microvolume is a candidate; if reproducibility matters and the sample is diluted for measurement, a quartz cuvette is. Checking the wavelength accuracy of the instrument also affects how the ratios read.

Common mistakes

  • Judging that the material is pure because 260/280 is about 1.8, and overlooking the presence of RNA or protein and the variation of the ratio with pH
  • Diluting with water, so that the ratio falls and purity is misread as poor
  • Setting concentrations measured by different methods side by side as they are

Check at your own site

  • By which method was your own concentration measured, and which value is used for calculating the amounts used downstream?
  • In what diluent is your own 260/280 measured?

Step 15: Residual host DNA/qPCR

Process-related impurity control that quantifies the residual E. coli genomic DNA, a safety concern, with high sensitivity and confirms it is within specification.Process-related impurity control that quantifies the residual E. coli genomic DNA, a safety concern, with high sensitivity and confirms it is within specification.

Standard methodQuantitative PCR (qPCR) targeting host genome-specific sequencesQuantitative PCR (qPCR) targeting host genome-specific sequences
Details and 3 alternatives

This step coversResidual host cell DNA (gDNA) (residual host DNA/qPCR)

Plasmid is made inside E. coli, so a small amount of the bacterium's own genomic DNA can get mixed in. This is a safety concern, so it is strictly controlled.

The measurement is quantitative PCR (qPCR), which amplifies only sequences specific to the E. coli genome. Picking up even very small amounts with high sensitivity and pinning down the residual amount as a number is the practical mainstream.

In other words, a test that confirms 'how much DNA other than the target plasmid remains.' Only by showing it is within the specification can the lot proceed to release.

If genomic DNA from E. coli is mixed into the plasmid, it becomes a safety concern. This is quantified with high sensitivity to confirm that it is within the specification. Measuring the residual host genome by sequence-specific qPCR is the practical mainstream.

MakersBio-Rad, Thermo Fisher, Applied Biosystems

Why it is the standard. qPCR is regarded as the most practical method for residual DNA quantitation, with high sensitivity and high precision (Charles River/industry reviews). Host gDNA is a representative process-related impurity CQA.

Check also. Quantitative PCR (qPCR) measures only the targeted host sequence, so it does not see the distribution of fragment lengths or unexpected contamination. The specification for residual host DNA varies with use and risk, and when origin or fragment length is also to be addressed, supplementation by digital PCR or next-generation sequencing is needed.

Alternatives in practice

  • Digital PCR (ddPCR) · Bio-Rad QX200 Droplet Digital PCR System — Absolute quantitation without a standard curve and robust to inhibition. Throughput is somewhat low
  • Estimation of host DNA in total dsDNA by fluorescent dye method · Thermo Fisher Quant-iT PicoGreen (P7589) — Simple, but not host-specific. Remains an indirect estimate
  • Southern blot · Bio-Rad transfer/hybridization equipment — Also evaluates the fragment size distribution. Labor-intensive, and quantitative accuracy is inferior to qPCR

Step guide

What you actually do

  1. Pre-treat (extract) the DNA to bring the sample into a state in which trace genomic DNA can be measured
  2. Run qPCR (or ddPCR) with primers and probes specific to the E. coli genome and with standard E. coli genomic DNA
  3. Obtain the quantity of host genomic DNA from the calibration curve and convert it to a proportion relative to the amount of plasmid (for example ng/mg pDNA)
  4. Run a sample with a known amount added (a spike) through the same procedure and confirm the recovery

Decision points

A commercial E. coli kit, or an in-house designed assay?
Commercial kits (for example the resDNASEQ Quantitative E. coli DNA Kit with the PrepSEQ Residual DNA Sample Prep Kit) come with the assay, the master mix and the standards. Decide whether to use one after confirming the target sequence, how fragment length is viewed, and the effect of the co-presence of your own plasmid.
Can it measure correctly even with a large amount of plasmid present?
What you want to measure is a trace of host DNA, while most of the sample is plasmid. The large amount of co-present DNA can hinder amplification, so confirm with dilutional linearity and spike recovery.
qPCR or ddPCR?
qPCR is highly sensitive and is regarded as the most practical method for residual DNA quantitation. ddPCR needs no standard curve and gives absolute quantitation robust to inhibition, but its throughput is on the low side. The fluorescent dye method (PicoGreen) can measure total double-stranded DNA simply, but it has no host specificity and remains an indirect estimate.
How do you set the specification?
Set it per amount of plasmid (ng/mg and the like), with the value decided by the use and the filing. Because it also bears on the total residual DNA that has to be removed in the downstream modality, work back from the downstream requirements.

Common mistakes

  • Treating a value from the fluorescent dye method, which measures total double-stranded DNA, as the host DNA value
  • Judging that nothing is detected in a sample with a large excess of plasmid, without confirming spike recovery
  • Not confirming the recovery of the pre-treatment extraction

Check at your own site

  • Has your own residual genomic DNA had its spike recovery confirmed in a sample with plasmid co-present?
  • Is your own residual genomic DNA specification set per amount of plasmid?

Step 16: Residual HCP/ELISA

A lot release item that quantifies residual E. coli protein, relevant to immunogenicity, by ELISA and shows conformance to specification.A lot release item that quantifies residual E. coli protein, relevant to immunogenicity, by ELISA and shows conformance to specification.

Standard methodHost cell protein-specific sandwich ELISAHost cell protein-specific sandwich ELISA
Details and 3 alternatives

This step coversResidual host cell protein (HCP) (residual HCP/ELISA)

Residual protein derived from the host E. coli (HCP) is also subject to control as an impurity. It cannot be overlooked from the standpoint of immune reaction and quality.

For measurement, a sandwich ELISA using antibodies specific to host protein is used to quantify the total. It is a method that can capture many kinds of protein together.

An item confirmed at the lot release stage, showing it is within the specification. It serves as proof of how well the drug substance has been 'washed free of bacterial protein.'

Residual protein from E. coli is also controlled as an impurity. Total HCP is measured by ELISA using host-specific antibodies to show it is within the specification. An item confirmed at lot release from the standpoint of immunogenicity and quality.

MakersTecan, Cygnus Technologies, BMG LABTECH, Thermo Fisher

Why it is the standard. HCP is quantified by ELISA as the standard (industry QC practice). Host-derived protein is a representative process-related impurity and is included in lot release specifications.

Alternatives in practice

  • Total protein quantitation (BCA/Bradford) · Thermo Fisher Pierce BCA Protein Assay Kit (23225) + plate reader — Simple, but not host-specific and with insufficient sensitivity at low concentrations
  • HCP profiling by LC-MS/MS · Thermo Fisher Orbitrap Exploris / Q Exactive + Vanquish/EASY-nLC — Identifies and quantifies individual HCPs. Complements ELISA but the operating burden is heavy
  • Indirect indicator of protein contamination by A260/280 ratio · Thermo Fisher NanoDrop One — Rapid but qualitative. Trace HCP cannot be detected

Step guide

What you actually do

  1. Add the diluted sample to a plate coated with anti-E. coli HCP antibody
  2. After washing, sandwich it with a labeled detection antibody, add the chromogenic substrate and read the absorbance on a plate reader
  3. Derive the concentration from a calibration curve made with the HCP standard
  4. Convert it to a proportion relative to the amount of plasmid (for example µg/mg pDNA)

Decision points

A commercial kit, or a process-specific assay?
Assess how much of your own HCP a commercial kit (for example the Cygnus Technologies E. coli HCP ELISA Kit) captures (the coverage). If it is insufficient, consider switching to an assay with antibodies raised against your own process.
Is ELISA enough, do you complement it with LC-MS/MS, or do you look at total protein?
ELISA is a test that measures the total quantity, and HCPs the antibody does not recognize are not counted. For important items, there is the option of complementing it by identifying individual HCPs by LC-MS/MS. Total protein quantitation such as BCA is simple but has no host specificity and lacks sensitivity at low concentrations.
Can it measure correctly even in a plasmid sample?
Because plasmid solutions contain DNA at high concentration, confirm with dilutional linearity and spike recovery that antibody binding is not being hindered.
How do you set the specification?
Set it per amount of plasmid, with the value decided by the use and the filing. From the standpoint of immunogenicity and quality, it is an item confirmed at lot release.

Common mistakes

  • Reading a low total quantity as safe, even though E. coli proteins the kit's antibody does not recognize cannot be counted
  • Reporting a value for a sample containing DNA at high concentration without confirming dilutional linearity
  • Treating a value from total protein quantitation (BCA and the like) as the HCP value

Check at your own site

  • With which lot of which kit was your own HCP value measured, and was dilutional linearity confirmed for plasmid samples?
  • Have you ever confirmed by LC-MS the HCPs that your own ELISA does not see?

Step 17: Residual RNA (residual RNA analysis)

Purity item that evaluates residual RNA, which skews quantitation and lowers purity, and gives final confirmation of removal by chromatography.Purity item that evaluates residual RNA, which skews quantitation and lowers purity, and gives final confirmation of removal by chromatography.

Standard methodResidual RNA evaluation by capillary gel electrophoresis (CGE) or agarose gelResidual RNA evaluation by capillary gel electrophoresis (CGE) or agarose gel
Details and 3 alternatives

If E. coli RNA remains, it is mixed in when the amount of plasmid is measured, skewing the value and lowering purity. So the residual amount in the final product is confirmed.

In a process that does not degrade RNA with an enzyme, RNA is physically removed in the chromatography steps. How well that worked is cross-checked by capillary gel electrophoresis or agarose gel.

What is looked at is the presence and amount of the RNA band. By showing that none remains, the test assures both the correctness of quantitation and the purity of the product.

If RNA from E. coli remains, it skews plasmid quantitation and lowers purity. In an RNase-free process, RNA is removed by chromatography, so the residual RNA is confirmed in the final product. The presence and amount of RNA bands are evaluated by CGE or gel.

MakersBio-Rad, Agilent, SCIEX, Thermo Fisher

Why it is the standard. RNA can be separated from plasmid isoforms and confirmed by electrophoresis, and CGE excels in quantitative reproducibility (pDNA QC practice). Residual RNA is a process-related impurity that affects purity and quantitation accuracy.

Alternatives in practice

  • RNA peak separation by AEX-HPLC · Agilent 1290 Infinity II Bio LC + Thermo Fisher DNAPac PA200 — Separates and quantifies RNA and pDNA by HPLC. Easy to share equipment
  • RNA-specific fluorescence quantitation (RiboGreen) · Thermo Fisher Quant-iT RiboGreen RNA Assay Kit (R11490) + plate reader — Selectively quantifies RNA. No size distribution information is obtained
  • Indirect evaluation by A260/280 and A260/230 ratios · Thermo Fisher NanoDrop One — Rapid and simple but qualitative. Low-level residual RNA is difficult to detect

Step guide

What you actually do

  1. Run the sample by capillary gel electrophoresis or on an agarose gel
  2. Detect it with a nucleic acid staining dye (SYBR Gold, SYBR Safe and the like)
  3. Look for any RNA band or peak apart from the plasmid peak
  4. Where needed, quantify with an RNA-specific fluorescent dye (RiboGreen and the like) or by AEX-HPLC

Decision points

Do you look at residual RNA qualitatively (presence or absence of a band), or quantify it?
In a process that does not use RNase, RNA is removed by chromatography, so the residual amount is confirmed in the final product. Some take as the specification that nothing is substantially detected by electrophoresis, while others quantify it and set a figure; it is decided by the use and the filing.
Is the method CGE, an agarose gel, AEX-HPLC or RiboGreen?
CGE and agarose gels let you look at the presence and size of RNA bands. AEX-HPLC can resolve RNA and plasmid as peaks and quantify them, and is a method whose instruments are easy to share. RiboGreen can quantify RNA selectively but gives no size distribution. Indirect assessment by A260/A280 is qualitative and cannot detect low levels of RNA.
How do you handle the limit of detection?
"Not detected" is a statement within the limit of detection of the method. State the method used and its limit of detection alongside the result in the specification and the records.

Common mistakes

  • Judging residual RNA from UV A260/A280 alone
  • Recording "not detected" without stating the limit of detection

Check at your own site

  • Your own "not detected" for RNA is a statement at which limit of detection of which method?
  • For your own RNA removal, have you confirmed at each stage of the process whether precipitation or AEX is doing the work?

Step 18: Endotoxin test (LAL)

A mandatory safety test that quantifies endotoxin, which causes strong fever and immune reactions, and brings it into conformance with an extremely low specification.A mandatory safety test that quantifies endotoxin, which causes strong fever and immune reactions, and brings it into conformance with an extremely low specification.

Standard methodBacterial endotoxin test by LAL (kinetic turbidimetric/kinetic chromogenic methods)Bacterial endotoxin test by LAL (kinetic turbidimetric/kinetic chromogenic methods)
Details and 3 alternatives

This step coversEndotoxin (bacterial endotoxin) (endotoxin test/LAL)

Endotoxin is a component from the outer membrane of E. coli and causes strong fever and immune reactions when it enters the body. It is controlled especially strictly for injectables.

The LAL method is used for measurement. Using the property that the horseshoe crab amebocyte extract reacts to endotoxin, very small amounts are quantified. Kinetic turbidimetric and chromogenic methods are used.

The specification is extremely low, and conformance is to levels such as generally below 0.1 EU/µg. Because it is directly tied to patient safety, it is a mandatory test that above all cannot be omitted.

Endotoxin from the outer membrane of E. coli causes strong fever and immune reactions, so it is strictly controlled. It is quantified by the LAL (horseshoe crab amebocyte lysate) method and brought into conformance with an extremely low specification according to use (generally below 0.1 EU/µg, etc.). A mandatory test directly tied to safety.

MakersLonza, Charles River, BioTek

Why it is the standard. LAL kinetic chromogenic method is the pharmacopoeial standard for endotoxin quantitation (USP <85>/Ph.Eur 2.6.14). A low specification of generally <0.1 EU/µg class is required for pDNA, a representative safety CQA.

Check also. Endotoxin from E. coli is measured by the LAL (horseshoe crab amebocyte lysate) method as the pharmacopoeial standard, but samples with high salt or high DNA concentration can inhibit or interfere with the reaction, and validation by dilution or spike recovery is needed. Under a policy of avoiding animal-derived materials, the recombinant Factor C (rFC) method is also an option. The specification value varies with route of administration and use.

Alternatives in practice

  • Recombinant factor C (rFC) method · Lonza PyroGene Recombinant Factor C Assay + fluorescence plate reader (Ex/Em 380/440 nm), or Fujifilm Wako PyroSmart NextGen — Sustainable, with no animal-derived material (independent of horseshoe crabs). Fluorescence detection
  • Gel-clot LAL method · Charles River / Lonza gel-clot LAL reagents + heat block — Minimal equipment and suited to limit testing. Low quantitation and throughput
  • Monocyte activation test (MAT) · Human whole blood/PBMC + cytokine ELISA (plate reader) — Also detects non-endotoxin pyrogens. Useful for overall pyrogenicity evaluation but cumbersome

Step guide

What you actually do

  1. Dilute the sample with endotoxin-free water to a concentration that does not interfere with the reaction
  2. Mix with LAL reagent (or rFC) and measure kinetically the time to the appearance of color or turbidity (by cartridge or on a plate)
  3. Derive the quantity from the calibration curve of the standard endotoxin and confirm with a positive control spiked with a known amount that the sample is not interfering with the reaction
  4. Convert to a value per amount of plasmid (for example EU/µg)

Decision points

LAL, or recombinant factor C (rFC)?
Where you want to avoid animal-derived reagents or place weight on continuity of supply, rFC is a candidate. When switching, measure the same sample by both and compare, and confirm its standing in the pharmacopoeias.
Kinetic or gel-clot? Cartridge or plate format?
If you quantify and track trends, kinetic chromogenic or turbidimetric methods are candidates; for a simple decision on whether a limit is exceeded, the gel-clot method is. The cartridge format suits rapid in-process decisions and the plate format suits release testing of many samples.
Does the buffer of the plasmid solution interfere with the reaction?
Buffer components (EDTA and the like) can inhibit or enhance the reaction. Confirm from the recovery of the positive control whether the interference can be overcome by diluting within the maximum valid dilution (MVD).
How do you set the specification?
Extremely low specifications are required depending on the use, and levels such as below 0.1 EU/µg are generally cited as examples, but the value is decided by the use and the filing. Set it by working back from the requirements of the downstream modality.

Common mistakes

  • Reading the value without noticing buffer interference and without looking at the recovery of the positive control
  • Not confirming that the containers and tips are endotoxin-free, so that the contamination comes from the testing side

Check at your own site

  • Has the buffer of your own plasmid solution been through the LAL interference test?
  • From the requirements of which downstream use was your own endotoxin specification decided?

Step 19: Sterility and bioburden tests

A pharmacopoeial safety test that confirms the absence of viable microorganisms in an injectable nucleic acid and the in-process microbial count, to assure patient safety.A pharmacopoeial safety test that confirms the absence of viable microorganisms in an injectable nucleic acid and the in-process microbial count, to assure patient safety.

Standard methodSterility test (pharmacopoeial) + bioburden test (pharmacopoeial)Sterility test (pharmacopoeial) + bioburden test (pharmacopoeial)
Details and 3 alternatives

This step coversSterility and bioburden (sterility and bioburden tests)

A test that confirms that there are no living microorganisms in the final product (sterility) and how many microorganisms were present partway through the process (bioburden).

The method follows that specified in the pharmacopoeia. While grasping the microbial count during manufacturing, it confirms for every lot that no viable organisms are detected in the final product.

For an injectable nucleic acid therapeutic that goes directly into the body, sterility is directly tied to patient safety. That is why this is a step in which the prescribed procedures are strictly followed to assure quality.

Confirm that the final product is free of living microorganisms (sterility) and the microbial count during the process (bioburden). Because it is directly tied to patient safety as an injectable nucleic acid therapeutic, it is tested for every lot according to the pharmacopoeial methods.

MakersMerck, Sartorius, Memmert, bioMérieux, Charles River

Why it is the standard. Sterility follows USP <71> and bioburden follows USP <61>, standard pharmacopoeial tests. Mandatory safety items for injectables.

Alternatives in practice

  • Rapid microbiological methods (RMM) · bioMérieux BacT/ALERT 3D (automated growth detection) or Charles River Celsis (ATP bioluminescence) — Shortens judgment to a few days. Validation and demonstration of pharmacopoeial equivalence are required
  • Bioburden by anaerobic/aerobic plate culture methods · Merck/Sartorius membrane filtration + agar plates — Standard for counting in-process bioburden. A different purpose from final sterility
  • Process validation by filter integrity testing · Sartorius Sartocheck 5 Plus / Merck Integritest 5 — Assures 0.2 µm sterile filtration. Integrity is confirmed by bubble point/diffusive flow

Step guide

What you actually do

  1. For sterility testing, filter the sample through a membrane filter, place the filter in aerobic and anaerobic media (for example TSB, FTM) and incubate for the specified period to look for growth
  2. For bioburden, collect the process fluid from before sterile filtration by the membrane filter method or similar, place it on agar medium and count the colonies that grow
  3. Run the positive and negative controls through the same procedure
  4. Record the results and compare them with the process trend and the alert levels you have set

Decision points

Is sterility testing by the pharmacopoeial culture method or a rapid method?
Rapid methods (BacT/ALERT 3D, Celsis using ATP bioluminescence and the like) can shorten the time to a result to a few days, but validation and demonstration of equivalence to the pharmacopoeial method are needed.
At which points and how often do you measure bioburden?
Measure at various points in the process, centered on the point before sterile filtration. The limits are set by the site from the risks of the process and the product, and are controlled by watching the trend.
How do you show assurance of sterile filtration?
For 0.2 µm sterile filtration, show verification that bacteria can be retained with the real fluid (a bacterial challenge test), integrity testing before and after use (bubble point, diffusive flow) and control of the bacterial count before filtration, taken together. An integrity test confirms that the membrane is not damaged and is no substitute for verification of its ability to retain bacteria. Nor does a sterility test give assurance of the filtration; because it is a probabilistic test, read it together with process control.
What about the testing laboratory environment?
Sterility testing is carried out in an isolator or a safety cabinet, and the environmental monitoring results for the testing laboratory are also kept in the records.

Common mistakes

  • Not building the number of days to a sterility test result into the shipping schedule
  • Confusing bioburden (viable count) with endotoxin (the amount of pyrogenic substance)
  • Using a rapid method for an existing decision without demonstrating equivalence

Check at your own site

  • On what basis and for which points were your own bioburden alert levels set?
  • Does your own sterility testing have the number of days to a result built into the shipping schedule?

Step 20: General physical property tests

Basic physical property items for a drug product that confirm appearance, pH and osmolality and assure stability and suitability for administration.Basic physical property items for a drug product that confirm appearance, pH and osmolality and assure stability and suitability for administration.

Standard methodAppearance (visual inspection), pH (potentiometry), osmolality (freezing point depression)Appearance (visual inspection), pH (potentiometry), osmolality (freezing point depression)
ReagentspH standard solutions (pH 4.01/7.00/10.01, Mettler Toledo/Merck), osmolality standard solutions (Advanced Instruments Clinitrol / each supplier's standard)
Details and 3 alternatives

This step coversGeneral physical properties (appearance, pH, osmolality) (general physical property tests)

A step that confirms the basic properties of appearance of the solution (whether it is clear, whether there is foreign matter or discoloration), pH and osmolality. It lays the groundwork as a drug product.

These govern stability and compatibility when put into the body (suitability for administration). Visual inspection and instrumental measurement are combined to confirm that quality is the same in every lot.

Unglamorous, but the foundation that holds down lot-to-lot variability. A confirmation item for the basic properties that support consistency as a drug product.

Check the appearance of the solution (clarity, foreign matter, discoloration), pH and osmolality. These are basic properties that govern stability and suitability for administration, and are confirmed for every lot by visual inspection and instrumental measurement. Items that assure consistency as a drug product.

MakersMerck, Advanced Instruments, Beckman Coulter

Why it is the standard. Appearance, pH and osmolality are basic properties based on the pharmacopoeial general tests (USP <1>/<791>/<785>, etc.) and are lot release items that assure the stability and suitability for administration of the drug product.

Alternatives in practice

  • Automated particle counting (light obscuration) · HACH/Beckman Coulter HIAC 9703+ liquid particle counter — Objectively quantifies insoluble particles (USP <788>). Complements visual inspection
  • Vapor pressure osmometry · ELITechGroup/Wescor VAPRO vapor pressure osmometer — Measurable with a small sample. Different principle from freezing point depression
  • Supplementary physical property confirmation by refractive index and conductivity · Mettler Toledo refractometer + conductivity meter — Simple monitor of concentration and salt concentration. For in-process confirmation rather than specification testing

Step guide

What you actually do

  1. In an inspection booth with black and white backgrounds, check visually for clarity and for any foreign matter or discoloration
  2. Calibrate the pH meter with standard solutions (pH 4.01, 7.00, 10.01 and the like) and measure the pH of the sample potentiometrically
  3. Calibrate a freezing point depression osmometer with standard solutions and measure the osmolality
  4. Record the results and set the values of each lot side by side

Equipment and materials

EquipmentVisual inspection boothpH meterOsmometer

Decision points

Is appearance inspection visual or by an automatic inspection machine?
Visual inspection is probabilistic in its detection and is influenced by the inspector's conditions. For lots with few vials, visual inspection is a candidate; where there are many, an automatic inspection machine is. Training of inspectors and fixing the inspection conditions (illuminance, background, time) are needed.
Do you add a test for subvisible particles?
Measurement of subvisible particles by light obscuration (USP <788>) complements visual inspection. Decide whether to add it according to whether the material is of a grade for injectable use or an intermediate.
Is osmolality by freezing point depression or by vapor pressure?
Freezing point depression is the norm. If you want to measure with a small sample, a vapor pressure osmometer is also a candidate, but the principle differs, so settle which value the specification is set on.
What do you match the specification to?
Decide it from the use, drug substance or injectable, and from how it is used downstream. At high concentration the osmolality reading and the appearance are affected, so fix the dilution conditions as well.

Common mistakes

  • Measuring a value outside the range of the standard solution calibration and recording it as it is
  • Misreading a slight difference in pH as manufacturing variation, without looking at fouling of the electrode or the effect of temperature

Check at your own site

  • Are your own appearance inspection conditions (illuminance, background, time) fixed in the procedure?
  • On a value from an instrument based on which principle is your own osmolality specification set?

Linear DNA (1): PCR amplification route(2 steps)

Step 21: Starting materials for the PCR method

Design and purity of the template and primers are the starting point that determines the quality of the linear DNA made by cell-free PCR.Design and purity of the template and primers are the starting point that determines the quality of the linear DNA made by cell-free PCR.

Standard methodDesign and preparation of a primer pair flanking the target sequence, using a synthetic gene fragment/plasmid as templateDesign and preparation of a primer pair flanking the target sequence, using a synthetic gene fragment/plasmid as template
Details and 1 alternative

This step coversPreparation of PCR template and primers (starting materials for the PCR method)

Instead of plasmid, this step prepares a template containing the target sequence and primers that fix its two ends. E. coli is not used, so no extra bacterial-derived sequences are carried in.

If the ends of the primers are modified, it becomes easier to separate them from leftover template in later purification. The template may be either a synthesized gene fragment or a small amount of plasmid.

To make linear DNA by PCR without using plasmid (= E. coli), a template containing the target sequence (a synthesized gene fragment, or a small amount of plasmid) and a primer pair defining both ends of it are prepared. Some designs modify the ends of the primers with phosphorothioate and the like to give exonuclease resistance and make the later selective purification easier. The sequence and purity of the template and the primer quality determine the fidelity of amplification and the final purity.

MakersGenScript, Twist Bioscience, Integrated DNA Technologies, Thermo Fisher Scientific

Why it is the standard. Being a cell-free method, it does not in principle carry in the bacterial backbone, antibiotic resistance genes or Gram-negative bacteria-derived endotoxin. Primer design defines both ends of the amplification product and the ease of later purification.

Alternatives in practice

  • Using synthesized long DNA (gene fragment) directly as template · Gene synthesis such as Twist Bioscience/GenScript — Prepares the template without going through plasmid construction. Feasibility depends on sequence length and GC content

Step guide

What you actually do

  1. Prepare a template containing the sequence of interest (a synthesized gene fragment, or a small amount of plasmid)
  2. Design and synthesize the primer pair that defines both ends of the sequence (the ends may be modified with phosphorothioate to make them resistant to exonuclease)
  3. Confirm the sequence, purity and concentration of the template and the primers
  4. Keep the incoming records and the quality documents (CoA and the like)

Equipment and materials

Materials and reagentsSynthesized gene fragment / template DNAPCR primers (synthetic oligos)

Decision points

Is the template a synthesized gene fragment or a plasmid?
Using a synthesized gene fragment directly as the template avoids going through a plasmid, but whether it can be synthesized depends on the length and GC content of the sequence. Where a plasmid is used as the template, consider, together with the design of the purification that follows, whether the E. coli backbone and genomic DNA are carried over with the template.
Do you modify the ends of the primers?
Making the ends resistant to exonuclease with phosphorothioate or similar makes it easier to design the selective purification that follows so that the product is kept while the template is digested away. Decide the position and type of the modification together with the choice of enzyme downstream.
With what do you confirm the quality of the template and the primers?
The sequence and purity of the template and the quality of the primers govern the fidelity of the amplification and the final purity. Decide in advance the items confirmed at incoming (sequence, purity, concentration, position of the modification) and the documentation. Whether GMP-grade supply is needed is also decided from the use.
Make it in house, or outsource it?
For linear DNA there are platforms that can take on everything from amplification through purification to specification testing. Whether you hold the equipment in house or outsource is chosen from the schedule, the scale and whether regulatory documents (a DMF and the like) exist.

Common mistakes

  • Proceeding to high-fidelity PCR without confirming the purity of the template, so that sequence errors creep in
  • Not noticing a mix-up in the position or type of the modified primer, so that the purification downstream does not work

Check at your own site

  • With what are the sequence and purity of your own template confirmed at incoming?
  • Together with the choice of which downstream enzyme was the end modification of your own primers decided?

Step 22: PCR method, drug substance equivalent

The central step that amplifies linear DNA cell-free in a short time while maintaining fidelity with a proofreading polymerase.The central step that amplifies linear DNA cell-free in a short time while maintaining fidelity with a proofreading polymerase.

Standard methodPCR amplification with a high-fidelity DNA polymerase having proofreading activity (hot start, large-volume reaction)PCR amplification with a high-fidelity DNA polymerase having proofreading activity (hot start, large-volume reaction)
Details and 1 alternative

This step coversLinear DNA amplification by high-fidelity PCR (PCR method, drug substance equivalent)

A step that PCR-amplifies the prepared template and primers with a polymerase that has a proofreading function, rapidly increasing linear DNA of the target sequence. Without waiting for cell culture, large amounts are obtained in hours to days.

Because bacteria are not used, it is fast and no extra sequences get in. On the other hand, fidelity that suppresses sequence errors and how evenly quality is maintained when the quantity is increased are where skill shows.

The template is PCR-amplified with a high-fidelity DNA polymerase having proofreading activity, giving a large amount of linear double-stranded DNA of the target sequence. Because no cells or fermentation are used, the advantage is speed, with large quantities obtained in hours to days, and it is used for IVT templates of mRNA, DNA medicines and vector starting materials. Fidelity (error rate) and, at scale, control of yield, uniformity and template carryover are the issues.

MakersNew England Biolabs, Thermo Fisher Scientific, Takara Bio, Roche

Why it is the standard. With 3'→5' proofreading activity, error rates orders of magnitude lower than Taq are achieved (values published by each supplier), and cell-free production avoids bacterial-derived impurities. The reference amplification method for obtaining linear DNA for IVT templates and DNA medicines on a short lead time.

Check also. Error rate, fidelity and long-range amplification capability are all values measured and published by manufacturers under their own conditions. In practice they vary with template, primers and scale.

Alternatives in practice

  • Cell-free DNA specialized for IVT templates (LineaDNA, etc.) · Applied DNA Sciences/LineaRx — PCR-based production under contract in GMP. Procures linear DNA template without owning equipment

Step guide

What you actually do

  1. Mix the template, primers, dNTPs, high-fidelity polymerase and reaction buffer to make the reaction mixture
  2. For large-volume reactions, dispense the reaction mixture into many vessels and control the temperature
  3. On a thermal cycler, repeat denaturation, annealing and extension after a hot start
  4. Confirm the size and quantity of the amplification product by electrophoresis or capillary electrophoresis and send it to the purification that follows

Decision points

What governs the choice of polymerase?
For enzymes with 3'→5' proofreading activity, error rates orders of magnitude below Taq are published by each supplier (for example NEB Q5, Thermo Fisher Platinum SuperFi II, Takara PrimeSTAR GXL, Roche KAPA HiFi). For nucleic acid medicine applications, choose a GMP-grade product. Use the published values only after confirming them with your own template and conditions.
How do you make up a large-volume reaction?
Configurations that combine dispensing and temperature control systems are cited as examples. At large volume, yield, uniformity and template carryover are the points at issue. Confirm the vessel-to-vessel variation in yield and the temperature uniformity of the cycler block from small scale upward.
How do you confirm fidelity?
Read the sequence of the amplification product by Sanger or next-generation sequencing and look at the error rate with your own template and conditions. For GMP applications, agree the frequency of sequence confirmation with the quality unit.
Is the PCR product acceptable as it is, or do you make it closed-ended?
The PCR approach is the quickest and easiest, but because the ends are open the product is more readily degraded during storage and in the body. For uses where a linearized template is all that is needed, such as an IVT template, PCR can be enough. Making it closed-ended becomes worthwhile where end stability or the exclusion of bacterial sequences counts.

Common mistakes

  • Using an enzyme without proofreading activity, or one that does not suit the conditions, so that sequence errors increase
  • Temperature becomes non-uniform when the volume is scaled up, so that the yield varies between vessels
  • Amplifying without deciding how template carryover will be removed in the later steps

Check at your own site

  • Has the sequence error rate of your own PCR product been measured with your own template and conditions?
  • Is the vessel-to-vessel variation in yield of your own large-volume reaction measured?

Linear DNA (2): enzymatic synthesis route(3 steps)

Step 23: Starting material for the enzymatic synthesis…Intensified option

The starting point at which a small amount of circular template with an integrated recognition sequence is prepared and everything after is left to isothermal, cell-free amplification.The starting point at which a small amount of circular template with an integrated recognition sequence is prepared and everything after is left to isothermal, cell-free amplification.

Standard methodPreparation of a circular template containing a recognition sequence (TelN, etc.) and chemical denaturationPreparation of a circular template containing a recognition sequence (TelN, etc.) and chemical denaturation
Details

This step coversPreparation and denaturation of the circular template (starting material for the enzymatic synthesis method)

In the enzymatic synthesis route, a small circular template containing the target sequence and a 'marker for closing the ends (recognition sequence)' is prepared. It is denatured to be ready for the next isothermal amplification.

Only a tiny amount of template is enough. From here on, no E. coli is used, and the lightness of this method is that amplification proceeds all at once with enzymatic reactions alone.

In the enzymatic synthesis (doggybone, dbDNA) route, a small circular template containing the target sequence and the recognition sequence of protelomerase (about 56 base pairs) is prepared and chemically denatured so that it can be subjected to rolling circle amplification (RCA). Only a very small amount of circular template is needed, and a feature of this route is that amplification to large quantities then proceeds by cell-free enzymatic reactions alone.

MakersGenScript, Touchlight, Aldevron

Why it is the standard. Only a trace of template is needed, and everything after can be amplified isothermally and cell-free. Incorporating the recognition sequence is the premise for the later end closure (doggybone formation).

Step guide

What you actually do

  1. Prepare a circular template containing the sequence of interest and the protelomerase recognition sequence (about 56 base pairs; TelN and the like)
  2. Take a small amount of the template and unwind it into single strands with a denaturing reagent
  3. Neutralize it and bring it to the pH of the enzyme reaction that follows
  4. Add the random primers and the like needed to initiate rolling circle amplification (RCA)

Equipment and materials

Materials and reagentsCircular template DNA (containing the recognition sequence)Primers to initiate RCA (random primers and the like)

Decision points

Does the sequence of interest clash with the recognition sequence?
Confirm at the entrance to the design that the telRL sequence for a TelN-based system, the ITRs for a system using AAV Rep, or the SS site for a Tel/pal system has not crept into the sequence of interest. The recognition sequence differs by enzyme family, and the template design is tied to the family chosen. You cannot switch the enzyme family alone afterwards.
Prepare the template in house, or leave it to a contract platform?
Only a tiny amount of template is needed, but there is the effort of designing and preparing a circular template containing the recognition sequence. There are also providers that can take on the work through to closing the ends (for example Touchlight dbDNA, Aldevron Alchemy), which is an option that keeps you from handling the enzymes in house.
Run the reaction in house with reagents, or outsource it?
In March 2026, Touchlight and NEB launched a benchtop kit (EnClose Cell-free dbDNA Synthesis Kit) that, according to the makers' announcement, can make dbDNA in 1 day, opening a route to buying it as a reagent. Choose from the equipment, the depth of verification and the grade required.
How far do you confirm the purity and quantity of the template?
The sequence and purity of the template determine the sequence identity of the final product. Confirm the sequence at incoming and see at small scale whether even a tiny amount amplifies sufficiently.

Common mistakes

  • The recognition sequence creeps into the sequence of interest, so that the end closing downstream occurs at an unintended position
  • Neutralization after denaturation is insufficient, so the pH falls outside that of the enzyme reaction that follows

Check at your own site

  • Was it confirmed at the design stage that your own sequence of interest does not clash with the recognition sequence of the enzyme family chosen?
  • Was in-house preparation or outsourcing of your own template procurement decided from the schedule and the documentation?

Step 24: Phi29 polymerase, RCAIntensified option

The heart of the enzymatic synthesis method, in which phi29's strand displacement and proofreading activity amplify the circular template in large quantities isothermally and cell-free.The heart of the enzymatic synthesis method, in which phi29's strand displacement and proofreading activity amplify the circular template in large quantities isothermally and cell-free.

Standard methodIsothermal rolling circle amplification (RCA/MDA) with phi29 DNA polymeraseIsothermal rolling circle amplification (RCA/MDA) with phi29 DNA polymerase
Details and 1 alternative

This step coversRolling circle amplification (phi29 polymerase, RCA)

The polymerase phi29 is very strong at advancing while unwinding double strands (strand displacement), and keeps reading around the circular template to make a long DNA in which the target sequence is strung like beads. This is rolling circle amplification (RCA).

It proceeds just by holding the temperature constant, with no need for E. coli culture or plasmid extraction. It also has a proofreading function, so it can earn volume while keeping the sequence accurate.

Using the strong strand displacement activity of phi29 DNA polymerase, the circular template is amplified isothermally (RCA) to make a long linear double-stranded DNA (concatemer) in which the target sequence is repeatedly joined. It scales easily as an isothermal, cell-free process, and only a trace of template is needed. Because phi29 has 3'→5' proofreading activity, it can amplify in large quantities while maintaining fidelity.

MakersNew England Biolabs, Thermo Fisher Scientific, Cytiva

Why it is the standard. Strong strand displacement, high processivity and 3'→5' proofreading activity allow high-fidelity, large-scale amplification isothermally and cell-free (published by suppliers). The standard amplification enzyme for enzymatic synthesis routes such as doggybone/dbDNA.

Alternatives in practice

  • primer-free enzymatic amplification (TruePrime) · 4basebio (hpDNA/opDNA/osDNA) — Synthetic DNA manufactured by primer-free enzymatic amplification. Contract/platform

Step guide

What you actually do

  1. Add phi29 polymerase, dNTPs, reaction buffer and random primers to the denatured circular template
  2. Hold at a constant temperature (for example around 30 °C for the wild type, 42 °C for the engineered EquiPhi29) and let replication continue around the template circle
  3. Confirm the progress of the reaction (the yield) over time
  4. Once the concatemer has formed, move it to the next enzyme reaction

Decision points

What governs the choice of phi29 product?
There are NEB phi29 (M0269), Thermo Fisher EquiPhi29 (faster at 42 °C), and Cytiva TempliPhi and GenomiPhi, among others. Their strand displacement is powerful and they have 3'→5' proofreading activity, so they can amplify while maintaining fidelity, but confirm the differences in reaction temperature, speed and grade with your own template.
Use primers, or go for primer-free enzymatic amplification?
Methods using random primers are the norm. There is also enzymatic amplification that needs no primers (4basebio TruePrime and the like), offered on a contract basis or as a platform.
How do you scale the reaction up?
Being isothermal and cell-free, it is a reaction that scales readily. At large volume, use a reaction system with agitation and temperature control; the uniformity of temperature and mixing feeds through to the uniformity of yield. Establish the relationship between reaction time and yield at small scale before scaling up.
How do you confirm fidelity?
Even with proofreading activity, measure the error rate with your own template and conditions. Confirmation of the sequence of the final product is done in the identity test downstream.

Common mistakes

  • The temperature is not constant, so the yield varies from reaction to reaction
  • Not confirming with controls the possibility that DNA carried into the reaction mixture or on pipettes is also amplified
  • Extending the reaction time to gain yield, so that by-products and carryover into the next enzyme reaction increase

Check at your own site

  • Was your own RCA yield decided after establishing the relationship between reaction time and temperature at small scale?
  • Does your own RCA confirm with a no-template control that no contaminating DNA is amplified?

Step 25: Doggybone formationIntensified option

The key enzymatic step that cuts the recognition sequence, covalently closes the ends and shapes closed-end linear DNA (doggybone).The key enzymatic step that cuts the recognition sequence, covalently closes the ends and shapes closed-end linear DNA (doggybone).

Standard methodCleavage of the recognition sequence and covalent closure by protelomerase (TelN)Cleavage of the recognition sequence and covalent closure by protelomerase (TelN)
Details and 1 alternative

This step coversEnd closure by protelomerase (doggybone formation)

Protelomerase is an enzyme that cuts a defined sequence within long strung-together DNA and folds back the cut ends and closes them by covalent bonds. A linear DNA with both ends sealed, in a distinctive 'bone (doggybone)' shape, is formed.

With closed ends, even if leftover 'junk' DNA (with open ends) is chewed away later with an enzyme, only the target remains undamaged. Another strength is that it can enclose only the target sequence without including extra sequences.

Protelomerase (TelN, etc.) cleaves the recognition sequence in the concatemer and turns the cut ends into hairpin ends closed by covalent bonds. This shapes it into linear DNA with both ends closed (doggybone/dbDNA). Closed ends are resistant to exonuclease, so in later purification they can be selectively separated from remaining open circular and linear DNA. The advantage is that only the target sequence can be enclosed in a minimal construct.

MakersNew England Biolabs, Touchlight

Why it is the standard. A dedicated enzyme that cleaves the recognition sequence (about 56 bp) to make covalently closed ends and shape doggybone/dbDNA. The exonuclease resistance of the closed ends makes the later selective purification work.

Alternatives in practice

  • Closure on a contract platform (dbDNA, etc.) · Touchlight dbDNA/Aldevron Alchemy — Contract manufacturing of cell-free DNA including closure. An option that avoids handling enzymes in-house

Step guide

What you actually do

  1. Add protelomerase (for example TelN) and reaction buffer to the concatemer reaction mixture
  2. React at the set temperature and time to cut the recognition sequence (about 56 bp) and close the cut ends covalently
  3. After the reaction, inactivate the enzyme or remove it by purification
  4. Confirm by electrophoresis or similar that closed-ended linear DNA has formed

Decision points

Which enzyme do you use?
TelN is a protelomerase from phage N15, and the enzyme itself is sold by NEB as TelN (M0651), EnClose TelN (M0768) and the like. Enzymes of other families, such as AAV Rep and Tel/pal, have different recognition sequences, and one template cannot be carried over to them as it is.
Carry out the end closing in house, or leave it to a contractor?
There are providers that can take on cell-free DNA manufacture including the end closing (for example Touchlight dbDNA, Aldevron Alchemy). It is an option that keeps you from handling the enzymes in house; choose from the equipment, the depth of verification and whether the documentation exists.
How do you confirm how far the end closing has gone?
Closed-ended DNA has the property of resisting exonuclease. Using this property, treating the material with exonuclease after the reaction and comparing it by electrophoresis lets you estimate the proportion that is closed. Verify the method of estimation yourself.
How do you handle the enzyme after the reaction?
Whether it is inactivated by heat or removed by chromatography and UF/DF downstream changes the conditions of the exonuclease treatment that follows. Whether confirmation of residual protelomerase is needed is also agreed with the quality unit.

Common mistakes

  • Not measuring how far the end closing has gone, so that the exonuclease that follows digests the DNA of interest as well and the yield falls
  • Carrying a template from a different family over to the enzyme being used as it is

Check at your own site

  • By which method is the completeness of your own end closing estimated, and is it set side by side across lots?
  • Can it be traced in the records that your own enzyme family matches the recognition sequence of the template?

Linear DNA (3): purification and finishing(2 steps)

Step 26: Selective removal of residual DNA

A purification stage that exploits the resistance of closed-end DNA to selectively degrade remaining open circular, linear and single-stranded DNA from the ends.A purification stage that exploits the resistance of closed-end DNA to selectively degrade remaining open circular, linear and single-stranded DNA from the ends.

Standard methodSelective degradation of residual linear DNA by end-dependent nucleases (Plasmid-Safe DNase/Exonuclease III, V, I, etc.)Selective degradation of residual linear DNA by end-dependent nucleases (Plasmid-Safe DNase/Exonuclease III, V, I, etc.)
Details and 1 alternative

This step coversExonuclease treatment (selective removal of residual DNA)

Exonuclease is an enzyme that trims DNA from its ends one nucleotide at a time. The target DNA with closed ends is not trimmed, and only the leftovers with open ends (fragments of template and backbone) are degraded.

In the PCR route, too, leftover primers and single-stranded DNA are cleaned up at this stage. The convenience of the end-dependent property is that it can protect the target and erase impurities selectively.

While leaving the target linear DNA, unneeded residual DNA is selectively degraded by enzyme. In the enzymatic synthesis route, closed-end doggybone DNA is resistant to exonuclease, while remaining open circular and linear template and backbone-derived DNA are degraded from the ends, so only the target can be selected and left. In the PCR route, too, it is used to remove residual primers, template and single strands.

MakersLGC Biosearch Technologies, New England Biolabs, Thermo Fisher Scientific

Why it is the standard. Closed-end/circular DNA has no ends and is a poor substrate, so only linear and open circular impurities can be selectively degraded. DNA derived from the bacterial backbone and residual template can be reduced at the enzyme stage.

Check also. Follow manufacturer-published values and manuals for optimal conditions, the need for cofactors (Mg2+, ATP) and activity units. After the reaction, confirm the enzyme has been inactivated and removed.

Alternatives in practice

  • Combined use of an internal-cleaving nuclease (Benzonase) · Merck Benzonase, etc. — Broadly reduces residual nucleic acids to small fragments. It has no end-dependent selectivity, so its use is distinguished

Step guide

What you actually do

  1. Add exonuclease (for example Plasmid-Safe ATP-Dependent DNase) and the cofactors (ATP at a final concentration of 1 mM, Mg²⁺) to the reaction mixture
  2. React at 37 °C to digest away residual template with open ends, backbone fragments and single strands
  3. Inactivate the enzyme by heating (for example 70 °C for 30 minutes)
  4. Remove the digestion products and the enzyme by chromatography and UF/DF downstream

Equipment and materials

Decision points

Which exonuclease do you use?
Plasmid-Safe digests open-ended linear double-stranded DNA while nicked circular and supercoiled molecules are protected. Exonuclease V (RecBCD) can digest single strands too and has a broader substrate range. Exonuclease III digests from the 3' side, and Lambda Exonuclease digests 5'-phosphorylated double-stranded DNA. If you suspect single-stranded carryover as well, Exonuclease V is a candidate; if you give priority to a track record in plasmid preparation, Plasmid-Safe is. Decide according to which oversight weighs more heavily in your own process.
How do you confirm the reaction conditions?
Plasmid-Safe does not work without ATP, so do not expect ATP to be left over in the fluid from the previous step; design the step to add it up to the specified concentration (the maker says 1 mM). If EDTA is left over from the previous buffer it chelates Mg²⁺ and the enzyme will not work. The inactivation temperature and time differ by enzyme.
How do you use this and Benzonase for different purposes?
Benzonase is an endonuclease that does not select for ends and degrades circular and supercoiled DNA and RNA as well. It cannot be used where you want to protect closed-ended or circular DNA of interest; it is used where you want to reduce nucleic acids wholesale, such as just after breaking cells.
How do you remove the enzyme?
Whether heat inactivation is enough or it is removed by chromatography and UF/DF is decided from the inactivation temperature and the conditions of the following steps. If inactivation is insufficient, enzyme activity may be carried into downstream qPCR.

Common mistakes

  • Carrying over EDTA from the previous step, so that the enzyme does not work
  • Too little ATP, so that the selectivity breaks down
  • Inactivation is insufficient, so enzyme activity is carried over into downstream qPCR

Check at your own site

  • Were the ATP and EDTA concentrations of your own exonuclease reaction mixture confirmed including the buffer from the previous step?
  • Were your own enzyme inactivation conditions decided against the conditions of the step that immediately follows?

Step 27: Linear DNA drug substance

Capture and polish by AEX/monolith, then UF/DF and sterile filtration to the drug substance. Confirmation of removal of residual enzymes, template and endotoxin is required.Capture and polish by AEX/monolith, then UF/DF and sterile filtration to the drug substance. Confirmation of removal of residual enzymes, template and endotoxin is required.

Standard methodCapture and polish by anion exchange (AEX)/monolith + UF/DF + sterile filtrationCapture and polish by anion exchange (AEX)/monolith + UF/DF + sterile filtration
Details and 1 alternative

This step coversChromatographic purification, UF/DF and sterile filtration (linear DNA drug substance)

A step that removes leftover enzymes, nucleotides, fragments and endotoxin and finishes at drug substance quality. DNA is captured by anion exchange or monoliths, using its negative charge, and ultrafiltration adjusts the concentration and the contents (buffer).

Because E. coli is not used, there is less host-derived dirt, but it is confirmed that the enzymes and template used and endotoxin have been properly removed. Finally it is sterile filtered and becomes a template for IVT, a starting material for vectors, or the drug substance of a DNA medicine.

Enzymes, nucleotides, degradation fragments and endotoxin are removed to finish at drug substance quality. Anion exchange (AEX) using the negative charge of DNA and monoliths capture and polish, and ultrafiltration/diafiltration (UF/DF) concentrates and exchanges the buffer. Because no cells or fermentation are involved, host-derived impurities are few, but confirmation of removal of residual enzymes (HCP equivalent), template and endotoxin is needed. Finally it is sterile filtered to make the drug substance for IVT templates, vector starting materials and DNA medicines.

MakersCytiva, Sartorius, Merck

Why it is the standard. Large-pore AEX and monoliths suit large linear DNA with slow diffusion, and UF/DF can concentrate and exchange composition. Even in cell-free methods, confirmation of removal of residual enzymes, template and endotoxin is a drug substance requirement.

Check also. Residual DNA (template), residual enzymes and endotoxin are reduced to specification and confirmed. Also watch for degradation from shear or excessive concentration.

Alternatives in practice

  • Contract manufacturing of cell-free DNA (including purification) · Touchlight/Applied DNA, LineaRx/Aldevron/GenScript — Contract service covering amplification through closure, purification and specification testing. Supplied in GMP grade

Step guide

What you actually do

  1. Load the reaction mixture onto a large-pore AEX resin or monolith column and bind the linear DNA
  2. Wash to flush out the enzyme, nucleotides and digestion fragments, then raise the salt and elute
  3. Concentrate by UF/DF and exchange into the final buffer
  4. Pass it through a 0.2 µm sterilizing-grade filter to give the drug substance
  5. Confirm by measurement that the residual enzyme, template and endotoxin have been removed

Decision points

Is the matrix a large-pore resin or a monolith?
For large linear DNA, which diffuses slowly, large-pore AEX or a monolith is a fit. With ordinary bead resins it is hard for the DNA to enter the pores and binding capacity is hard to obtain. Choose the matrix by measuring binding capacity at the length of your own linear DNA.
What do you confirm as the targets for removal?
Because no cells or fermentation are involved, host-derived impurities are on the low side, but confirm the removal of the enzymes used (the equivalent of HCP), the template and endotoxin. For the enzymes, measure the amount by the dedicated ELISA for each product.
Build the purification in house, or outsource it (purification included)?
There are providers that can take on everything from amplification through end closing, purification and specification testing and supply the material at GMP grade (for example Touchlight, Applied DNA Sciences' LineaRx, Aldevron, GenScript). Whether you hold purification equipment and verification in house is decided from the scale and the frequency.
Do the final buffer and concentration change with the use?
The conditions on the user's side differ between an IVT template, a vector starting material and a DNA drug substance. The purity of the template bears directly on the amount of dsRNA generated downstream, so decide from the conditions on the user's side.

Common mistakes

  • Not measuring the residue of the enzymes used, so that it is found downstream
  • Using an ordinary bead resin for large, slowly diffusing DNA, so that binding capacity falls short
  • Raising the flow rate too far in UF/DF, so that long DNA is broken

Check at your own site

  • Is the residual enzyme in your own drug substance measured with a kit that matches the product used?
  • Did your own purification choose the matrix by measuring binding capacity at the length of the linear DNA?

The reference (“gold standard”) method is the one broadly recognized in published practice and guidelines; your process, product and regulator may justify another. Makers and products are examples, not endorsements. This map is translated from the Japanese edition, where it is updated first (Japanese version).