18Step 18: Vector genome titer (ddPCR)
ddPCR gives absolute vg quantitation, the denominator that is the starting point of all CQAs, deciding dose, empty/full ratio and lot uniformityddPCR gives absolute vg quantitation, the denominator that is the starting point of all CQAs, deciding dose, empty/full ratio and lot uniformity
Standard methodAbsolute quantitation by digital PCR (ddPCR)Absolute quantitation by digital PCR (ddPCR)
ReagentsddPCR Supermix (for probes)TaqMan probes (FAM/HEX-labeled)ITR/transgene-specific primersDNase IRestriction enzyme Details and 3 alternatives
This step coversAbsolute quantitation of vector genome titer (vg/mL, GC/mL) (vector genome titer / ddPCR)
A step that accurately counts the amount of genome packaged in capsids (vg/mL) by digital PCR (ddPCR). It is the primary specification when the dose is set in vg/dose.
The value measured here is the "denominator" when the ratio to infectious titer (vg/IU) and the empty/full ratio are calculated. In other words, many quality indicators are built up from this number.
It is the basis that supports dose determination and dose uniformity between lots. It can be called the foundational quantitation that is the starting point of all critical quality attributes (CQAs).
This is the step that becomes the primary specification when the dose is set in vg/dose. The genome amount measured here is the denominator when the ratio to infectious titer (vg/IU) and the empty/full ratio are calculated, and it is the starting point of every CQA. It decides the dose, decides the numerator of the full:empty ratio (the amount of genome packaged), and also serves as the basis for whether the dose is uniform from lot to lot.
MakersBio-Rad, Applied Biosystems
Why it is the standard. It does not rely on a standard curve and counts even low-efficiency reactions as positive 1 molecule at a time. It therefore has a smaller CV than qPCR (generally under 10%), and values are easily consistent even across sites. Underestimation is also unlikely with scAAV, which has secondary structure, and it is regarded as the de facto reference method that can absolutely quantitate the AAV genome titer.
Alternatives in practice
- Quantitative PCR (qPCR) · Applied Biosystems QuantStudio 7 Pro + TaqMan Fast Advanced Master Mix — Depends on a standard curve, so CV is larger than ddPCR. Widely available
- Genome titer estimate from UV absorbance · Thermo NanoDrop One / spectrophotometer (A260/A280) — Simple, but cannot distinguish empty/full or free nucleic acids. For screening use
- CDMS (charge detection MS) · Thermo Scientific Orbitrap (CDMS mode) / Megadalton Solutions — Directly evaluates the encapsidated genome by mass. Specialized and expensive instrument
Step guide
What you actually do
- Add DNase I to the sample to digest free DNA outside the capsids
- Open the capsids with proteinase K or similar to release the genomes inside, and dilute stepwise with diluent
- Mix with the reaction mix (Supermix, primers, probe), partition into droplets, amplify and count positives and negatives
- Obtain the copy number by Poisson statistics, apply the dilution factor back to give vg/mL, and judge the result together with that of the reference standard
Decision points
- Is the target the ITR, the transgene, or both?
- The ITR is common to every construct and can be measured with the same target even when the construct changes, but it has the weakness of being hard to amplify because it is a GC-rich hairpin. The transgene side amplifies stably but, depending on the position of the target, undercounts partial genomes. There are also configurations that measure both in the same well. A value aimed at the ITR and a value aimed at the transgene count different quantities, so do not compare them side by side.
- How do you fix the order and conditions of DNase treatment and capsid digestion?
- It is reported that the value moves greatly with the DNase treatment time, whether inactivation is needed, the temperature and time of capsid digestion, and whether dilution or heating comes first. There are cases where breaking the capsids with heat before dilution gave more than a 10-fold decrease. Write the figures out in full in the procedure and, when conditions are changed, set the before and after against each other.
- ddPCR, or qPCR?
- ddPCR needs no standard curve and is relatively robust to inhibitors, so its adoption for measuring genome titer is spreading. For qPCR too, there are reports that accuracy close to ddPCR was obtained by using a reference standard for the calibration curve and refining the sample preparation. Choose according to whether systematic bias or run-to-run variability weighs more heavily in your own process.
- What do you use as the reference standard?
- Public standards such as ATCC AAV2 and AAV8, or your own in-house standard, are used as the calibration reference point for the assay. Supply is limited, so settle how they are used and the procedure for switching lots (bridging old to new).
Common mistakes
- Comparing figures with different targets and sample preparation side by side merely because the report says "measured by ddPCR"
- Changing the order to heating before dilution, so that the value moves by an order of magnitude
- Not bridging old to new when switching the standard lot, and losing continuity of the data
Check at your own site
- Is your own genome titer measured under a procedure that fixes the target, the sample preparation and the reference standard?
- When your own value and a contract laboratory's value diverge, what do you align and check first?
19Step 19: Total capsid titer, full◇ Branches
A step that measures total particles and empty capsid fraction by SV-AUC and pins down the quality indicator vg/cp ratioSerotype-specific ELISA cannot recognize engineered capsids, so total particles are measured by antibody-independent methods
Standard methodSedimentation velocity analytical ultracentrifugation (SV-AUC)Antibody-independent methods such as mass photometry / SEC-MALS (ELISA is unsuitable for engineered capsids)
EquipmentAUCRefeyn mass photometers (TwoMP/SamuxMP), SEC-MALS (Wyatt DAWN), CDMS ReagentsLabel-free (no labeling, UV absorbance detection)Analysis software (SEDFIT / UltraScan)
◇ With Engineered capsidAntibody-independent methods such as mass photometry / SEC-MALS (ELISA is unsuitable for engineered capsids)◇ With Natural serotypeSedimentation velocity analytical ultracentrifugation (SV-AUC)
Details and 4 alternatives
This step coversQuantitation of total capsid titer (cp/mL) and full:empty ratio (full = filled : empty = empty) (total capsid titer, full/empty ratio / SV-AUC)
A step that measures the "total number" of particles administered and the proportion of them that contain contents. Total capsid titer (cp/mL) and full:empty ratio are quantitated by sedimentation velocity analytical ultracentrifugation (SV-AUC).
Combining the two gives the vg/cp ratio (genome packaging efficiency), a figure showing how efficiently the genome could be packed.
The empty capsid fraction bears on immunogenicity, so these become critical quality attributes (CQAs) representing product quality. It is a step that pins down both quality and quantity of particles at the same time.
A step to pin down the total number of particles administered and the proportion of empty capsids, which bears on immunogenicity. Expressed in addition as the vg/cp ratio (the efficiency with which genomes were packaged), it becomes a critical quality attribute (CQA) that governs product quality.
MakersBeckman Coulter, Refeyn
Why it is the standard. It separates empty, partial, full and aggregated particles at once with high resolution and measures the amount of each. Moreover, measurement does not depend on labels or reference materials. With these features, it is widely accepted as the reference method for measuring the full:empty ratio.
Check also. Total capsid titer is complemented by combining capsid ELISA, mass photometry, SEC-MALS, AUC and others (there is no single absolute standard).
◇ With Engineered capsid. Capsid ELISA (e.g., PROGEN) recognizes serotype-specific conformational epitopes, so reactivity drops or disappears with engineered capsids, leading to underestimation. Total particle counts are obtained by antibody-independent methods such as mass photometry (MP), SEC-MALS and charge detection mass spectrometry (CDMS).
Alternatives in practice
- Total capsid ELISA · Progen AAV Titration ELISA (serotype-specific, sandwich format) + plate reader — Simple, high throughput. Possible underestimation due to dependence on conformational epitopes
- Mass photometry · Refeyn SamuxMP Mass Photometer — Small sample volume and rapid, obtains empty/full/partially filled as a distribution. Complementary to AUC
- AEX-HPLC · Thermo Scientific DNAPac/ProPac / Agilent 1290 Infinity II Bio LC + AEX column — Rapid quantitation of total capsid and full/empty ratio. Depends on resin conditions
- UV A260/A280 ratio · Spectrophotometer (Thermo NanoDrop / Agilent Cary) — Simple estimate of full:empty. Limited to high-purity samples
Step guide
What you actually do
- Adjust the sample with formulation buffer, load it into the AUC cell, measure by SV-AUC and derive the proportions of empty, partial, full and aggregated species from the sedimentation coefficient distribution
- Measure the total capsid count separately by capsid ELISA, analytical AEX or mass spectrometry-based methods (mass photometry and the like)
- Divide the genome titer (vg/mL) by the total capsid count to calculate the vg/cp ratio (the efficiency of genome packaging)
- For each measurement, record the value of the reference standard, the method used and the analysis conditions
What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, the total particle count can be measured by a serotype-specific capsid ELISA. With engineered capsids, the epitope the ELISA recognizes changes, so reactivity drops or disappears and the count can be underestimated. Obtain the total particle count by antibody-independent methods such as mass photometry, SEC-MALS and CDMS)
Decision points
- With what do you measure the total capsid count?
- Capsid ELISA is simple and high-throughput, but it recognizes serotype-specific conformational epitopes, so it depends on antibody reactivity and can be thrown off by aggregation or the buffer. Antibody-independent methods such as SEC-MALS and CDMS are less affected by reactivity but place a greater burden on instrumentation. Choose after confirming that reactivity is retained for your serotype and formulation.
- Do you use AUC for routine lot decisions?
- AUC is strong as the yardstick (the reference method) against which figures from other methods are set, but its throughput is low and it requires sample volume and skill. A common split in practice is to run routine lot decisions on AEX-HPLC or a combination of ddPCR and ELISA, having set them against AUC once.
- When the ratios disagree between methods, which one do you make the specification?
- The empty/full ratio is defined differently by method, for instance in which side partially filled capsids are counted, and the values do not agree. State the measurement method in the specification and, when changing method, keep the data from measuring the same sample by both and setting them against each other.
Common mistakes
- Obtaining the total particle count of an engineered capsid by ELISA and underestimating it without noticing the drop in reactivity
- The AUC analysis conditions (boundary fitting, how peaks are delimited) differ between analysts, so decisions are not aligned
- Judging the fill fraction from the ratio of ddPCR to ELISA alone, counting partially filled capsids on the filled side
Check at your own site
- Does your own empty/full ratio specification state the measurement method and the analysis conditions as well?
- Is there a plan to re-confirm reactivity for your own total capsid count when the serotype is changed or the capsid is engineered?
Separates empty, partial and full by sedimentation coefficient difference and absolutely quantitates the CQA that governs titer, dose design and safetySeparates empty, partial and full by sedimentation coefficient difference and absolutely quantitates the CQA that governs titer, dose design and safety
Standard methodSedimentation velocity analytical ultracentrifugationSedimentation velocity analytical ultracentrifugation
ReagentsRotorSample sector buffer
Details and 4 alternatives
This step coversAbsolute quantitation and reference confirmation of the empty / full / partial capsid ratio (Empty/Full/Partial) (empty/full/partial capsid ratio / SV-AUC)
A step that divides capsids into 3 types, "empty, full and partial," and absolutely quantitates their ratio. It is measured by sedimentation velocity analytical ultracentrifugation and confirmed with a reference.
The proportion of full capsids that properly encapsulated the therapeutic genome directly governs quality. It decides titer, is the basis of dose design, and bears directly on safety.
That is why this ratio is a critical quality attribute (CQA) that regulators require to be shown in submissions without fail. It can be called the step that guarantees the contents of the product in numbers.
The proportion of full capsids that have properly encapsulated the therapeutic genome governs quality. It decides titer, is the basis of dose design, and bears directly on safety. That is why this proportion is a critical quality attribute (CQA) that regulators require to be shown in submissions without fail.
MakersBeckman Coulter, Refeyn
Why it is the standard. Capsids sediment differently (sedimentation coefficient) depending on the amount of contents. So empty (hollow, about 63S), partial (only partly filled) and full (about 93S) can be told apart by that difference, separated without labels, and even the amount of each measured accurately. It is also a method that the industry has long accepted as the reference method.
Alternatives in practice
- Mass photometry (MP) · Refeyn SamuxMP (calibrated with empty AAV9, 3.74 MDa) — Empty/full/partially filled ratio from the molecular weight distribution. Small sample volume, rapid, highly correlated with AUC
- AEX-HPLC/UPLC · Agilent 1290 Infinity II Bio LC + AEX column / Thermo DNAPac — Fast, highly reproducible full/empty separation. Calibration samples are needed
- CDMS / native MS · Thermo Orbitrap (CDMS) / Megadalton Solutions — Directly judges empty/full by single-particle mass. Specialized instrument
- UV spectroscopy A260/A280 · Spectrophotometer (Thermo NanoDrop) — Simple estimate of the full ratio. Accuracy is limited for mixtures
Step guide
What you actually do
- Load the sample with formulation buffer into the AUC sector, mount it in the rotor, centrifuge, and record the sedimentation boundary continuously with the absorbance or interference optics
- Obtain the sedimentation coefficient distribution c(s) with SEDFIT or similar and turn the peak areas for empty, partial, full and aggregated species into proportions
- Compare the results with orthogonal methods (analytical AEX, CDMS, TEM and the like) and confirm that the proportions are valid
- Fix the measurement conditions and the analysis parameters and record them together with the results
Decision points
- When you place AUC as the reference method (the yardstick against which values from other methods are set), how do you hold down variability in the analysis?
- Results move with cell preparation, the optics and the analysis parameters (boundary fitting, baseline, how peaks are delimited). Standardize the procedure, verify that decisions are aligned between analysts, and record the analysis conditions together with the figures.
- What do you choose as orthogonal methods, and how do you set them against each other?
- Analytical AEX is fast and suits routine lot control. CDMS resolves the gradation by mass, 1 particle at a time. TEM is used as a cross-check that confirms the state of separation in an image. Each technique handles partially filled capsids differently, so align the premises before comparing.
- What do you confirm with the reference?
- Measure known empty and full standards under the same conditions and confirm that the sedimentation coefficients or masses agree with the known values. As an example, there are reports that the empty species appears at about 63S and the full species at about 93S, but these move with serotype and conditions, so confirm them in your own system. Record the standard lot and the measurement history.
- How do you handle the constraints on sample volume and concentration?
- Because AUC detects the sedimentation boundary optically, it requires a concentration and a volume above a certain level. It is hard to apply to the dilute, small in-process samples, and the buffer's UV absorbance, density and viscosity also affect the measurement. Confirm the sample prerequisites first.
Common mistakes
- Setting the AUC and AEX empty/full ratios side by side while ignoring the difference in how partially filled capsids are handled
- Leaving the analysis parameters to the analyst, so that different proportions come out of the same raw data
- Forcing AUC onto small, dilute in-process samples and losing precision
Check at your own site
- Does your own reference method for the empty/full ratio fix the analysis conditions and verify reproducibility between analysts?
- Do your own orthogonal methods include at least one technique based on a different principle?
21Step 21: Genome integrity (CGE-LIF)
Full-length integrity of the encapsidated genome is evaluated by CGE-LIF, because truncated species cause poor expression and immune riskFull-length integrity of the encapsidated genome is evaluated by CGE-LIF, because truncated species cause poor expression and immune risk
Standard methodCapillary gel electrophoresis under denaturing conditions + laser-induced fluorescence detectionCapillary gel electrophoresis under denaturing conditions + laser-induced fluorescence detection
ReagentsBenzonase (nuclease)Proteinase KGuanidine hydrochloride (DNA purification)Intercalating fluorescent dyeSize standard (DNA ladder)AAV genome integrity assay kit Details and 4 alternatives
This step coversEvaluation of genome integrity (whether the encapsidated genome is full length ITR-to-ITR as designed, and whether there are partial genomes / truncations / rearrangements) (genome integrity / CGE-LIF)
A step that confirms whether the encapsidated genome is "full length as designed." It examines whether it is continuous from ITR to ITR without breaks, and free of partial genomes, truncations and rearrangements.
Capillary gel electrophoresis under denaturing conditions and laser-induced fluorescence detection are used. Contamination with broken genomes is distinguished with high sensitivity.
Truncated species lead to poor transgene expression and the risk of immune response. That is why the full-length integrity of the genome is evaluated as a CQA that governs both titer and safety.
If the encapsidated genome is partial or broken partway, the transgene may not be expressed well. Such broken genomes (truncated species) also lead to the risk of triggering an immune response. That is why the full-length integrity of the genome is carefully evaluated as a critical quality attribute (CQA) that governs both titer and safety.
MakersBio-Rad, Merck, Agilent, SCIEX, Illumina
Why it is the standard. Compared with agarose gels and Southern blots, it has higher resolution and also excellent reproducibility. It can therefore accurately quantitate the ratio of full-length to partial genomes. Another reason for adoption is that it is widely used in the industry as a reference method for measuring AAV genome integrity.
Alternatives in practice
- PacBio SMRT/HiFi long-read sequencing · PacBio Revio / Sequel IIe — Full length, ITR integrity and recombination at the single-molecule level. More detailed than CGE but higher cost
- Duplex/milepost ddPCR · Bio-Rad QX600 Droplet Digital PCR — Detects truncation by the genome 5'/3' ratio. Sequence detail is not obtained
- Alkaline denaturing agarose gel · Bio-Rad Sub-Cell + ChemiDoc — Simple confirmation of the encapsidated single-stranded genome. Resolution is inferior to CGE
- Short-read NGS (Illumina) · Illumina NextSeq 2000/MiSeq — Sequence identification and detection of mutations/contamination. Weak for long-range structure
Step guide
What you actually do
- Treat the sample with nuclease to remove nucleic acids outside the capsids, break the capsids with proteinase K or similar, and purify the genomes
- Load into the capillary under denaturing conditions and detect an intercalating dye by laser-induced fluorescence (LIF)
- Compare with the size standard (DNA ladder) and obtain the peak area ratios of full-length genomes, partial genomes and truncated species
- Where needed, investigate the position of truncations and any recombination by long-read sequencing or duplex ddPCR
Decision points
- Is CGE-LIF enough, or do you add long-read sequencing?
- CGE-LIF has high resolution and reproducibility and suits quantifying the ratio of full-length to partial genomes. Long-read sequencing can see ITR integrity and recombination at the single-molecule level and is more detailed, but the cost and the analysis burden are greater. Think of the main quantitative method and the complementary method for confirming sequence detail separately.
- How do you fix the sample preparation (removal of external nucleic acids, genome purification)?
- If external nucleic acids remain they give false peaks, and if capsid digestion is insufficient the genomes do not come out. Confirm the nuclease treatment and capsid digestion conditions and the recovery of the purification first, and fix the procedure.
- How do you use ddPCR and alkaline denaturing agarose gels for different purposes?
- Duplex ddPCR looks at truncation from the ratio of the 5' side to the 3' side and does not give sequence detail. Alkaline denaturing agarose gels can be used for a simple check of single-stranded genomes, but their resolution is lower than CGE, so they suit screening.
Common mistakes
- Removal of external nucleic acids is insufficient, so peaks that are not full length are overestimated
- Substituting ddPCR aimed at one side only for the assessment of genome integrity, and missing partial genomes
- The range of the size standard does not match the genome length of the construct, so sizes are assigned incorrectly
Check at your own site
- Does your own assessment of integrity confirm the recovery of the sample preparation and the range of the size standard for each construct?
- Are you tracking which upstream changes (plasmids, packaging) increase or decrease your own truncated species?
22Step 22: VP1:VP2:VP3 ratio (CE-SDS)
CE-SDS measures the VP1:VP2:VP3 ratio, monitoring capsid assembly and transduction efficiencyCE-SDS measures the VP1:VP2:VP3 ratio, monitoring capsid assembly and transduction efficiency
Standard methodCE-SDS (sodium dodecyl sulfate capillary electrophoresis, UV absorbance detection)CE-SDS (sodium dodecyl sulfate capillary electrophoresis, UV absorbance detection)
Details and 4 alternatives
This step coversQuantitation of the capsid protein VP1:VP2:VP3 ratio (VP stoichiometry) (VP1:VP2:VP3 ratio / CE-SDS)
A step that measures the blend ratio of the three proteins that assemble the capsid, VP1:VP2:VP3. It is quantitated by CE-SDS (UV detection).
This ratio bears on whether the virus capsid assembles properly. It also affects the efficiency of infection and transduction (delivery of genes into cells).
That is why it is a critical quality attribute that serves as a yardstick for watching lot-to-lot variability and as an indicator of whether the manufacturing process is running stably.
The VP ratio is one of the critical quality attributes. It bears on whether the virus capsid assembles properly, and also affects the efficiency of infection and transduction. That is why it serves as a yardstick for watching lot-to-lot variability and as an indicator of whether the manufacturing process is running well.
MakersBio-Rad, Agilent, Waters, SCIEX, Progen
Why it is the standard. It is the successor method that evolved SDS-PAGE into high resolution with automated quantitation. %VP1:%VP2:%VP3 can be calculated reproducibly from the peak area of each VP band, and its advantage is that it is not easily affected by sample concentration. With these strengths, it is widely used as the industry standard for VP ratio measurement.
Alternatives in practice
- Reversed-phase LC-UV / RP-UPLC · Agilent 1290 Infinity II Bio LC / Waters ACQUITY Premier + C4 column — Separation and ratio quantitation of intact VPs. Complementary to CE-SDS
- SDS-PAGE densitometry · Bio-Rad Criterion/Mini-PROTEAN + ChemiDoc (Coomassie/silver stain) — Simple, low cost. Quantitative reproducibility is inferior to CE/LC
- RP-LC-MS · Thermo Vanquish + Q Exactive/Orbitrap (intact VP mass + relative quantitation) — Obtains VP identification and ratio at the same time. Instruments and analysis are advanced
- Western blot · Bio-Rad transfer + anti-VP (B1) and serotype-specific antibodies (Progen) — For identity confirmation. Quantitation is limited
Step guide
What you actually do
- Heat the sample under SDS and reducing conditions to separate the capsid into its individual VP proteins
- Inject into a capillary filled with SDS-MW gel buffer and apply voltage to separate by size
- Detect the peaks by UV (214 or 220 nm) and identify the VP1, VP2 and VP3 peaks against the internal standard
- Calculate %VP1, %VP2 and %VP3 from the peak areas and record them
Decision points
- CE-SDS, SDS-PAGE, or reverse-phase LC / LC-MS?
- CE-SDS quantifies automatically and can calculate the ratios reproducibly from the peak area of each VP. SDS-PAGE is simple and low-cost but less reproducible for quantitation. Reverse-phase LC and LC-MS also give the VP masses at the same time, but the instrument and analysis burden is greater.
- How do you decide the reduction and heating conditions?
- The type and concentration of the reducing agent and the temperature and time of heating affect peak separation and recovery. The ratios can move even with a small change, so fix the conditions and compare before and after when they are changed.
- How do you set the specification for the VP ratio?
- The VP ratio is regarded as a quality attribute related to how the capsid assembles and to the efficiency of infection and gene delivery. The expected ratio changes with serotype and production system, so do not carry over values from other companies or the literature; decide the range from the variability of your own development lots.
Common mistakes
- Changing the heating or reduction conditions in the sample preparation and mistaking the resulting shift in the ratio for a lot-to-lot difference
- The peak integration ranges differ between analysts, so the ratios are not aligned
- Using the staining intensity of an SDS-PAGE gel directly as the ratio, overlooking the limits of its quantitative reproducibility
Check at your own site
- Is your own range for the VP ratio decided from the variability of development lots?
- Are the peak integration ranges for your own VP ratio fixed in the procedure?
23Step 23: Capsid identification, PTM analysis (LC-MS)◇ Branches
LC-MS/MS characterizes, site by site, the identity of the serotype VP sequence and the PTMs that affect transduction efficiencyRather than identifying the serotype, the reference is to confirm the introduced modification (insertion/mutation) by sequence and mass
Standard methodLC-MS/MSLC-MS/MS peptide mapping + intact/subunit MS (confirming the sequence and mass of the modified site)
◇ With Engineered capsidLC-MS/MS peptide mapping + intact/subunit MS (confirming the sequence and mass of the modified site)◇ With Natural serotypeLC-MS/MS
Details and 4 alternatives
This step coversIdentity of the capsid proteins (serotype confirmation) and characterization of post-translational modifications (PTMs) (capsid identification, PTM analysis / LC-MS)
A step that confirms whether the capsid protein (VP) is "the serotype as designed" and also examines its chemical modifications. LC-MS/MS is used.
First, identity: confirming that the VP sequence is that of the intended serotype. Next, post-translational modifications (PTMs): profiling where deamidation, oxidation, acetylation, phosphorylation and so on are present.
PTMs can affect the vector's transduction efficiency and infectious titer, so the step goes beyond confirming the sequence and characterizes what modifications are present.
Identity confirmation and PTM characterization of the capsid protein (VP) are needed for 2 reasons. The 1st is to confirm that the VP sequence is that of the serotype as designed. The 2nd is that post-translational modifications (PTMs) such as deamidation, oxidation, acetylation and phosphorylation can affect the vector's transduction efficiency and infectious titer. So the identity of the sequence is confirmed first, and then which PTMs are present, and where, is profiled.
MakersWaters, Promega, SCIEX, Progen
Why it is the standard. The procedure has 2 stages. First, intact mass confirms the VP sequence of each serotype and N-terminal processing (removal of the initiator methionine, N-terminal acetylation, acetylation of VP3, etc.). Peptide mapping then identifies and quantitates, site by site, more than 30 PTM sites (deamidation, oxidation, acetylation, phosphorylation) while covering nearly 100% of the sequence. Because it can pin down this much, it is positioned as the reference method for evaluating identity and PTMs.
◇ With Engineered capsid. Serological identification of natural serotypes cannot be applied. For engineered capsids, LC-MS/MS peptide mapping directly confirms the sequence of the inserted peptide / mutation site, intact/subunit MS verifies the VP mass shift, and NGS of the cap gene verifies conformity to design as needed.
Alternatives in practice
- RP-LC-MS of intact VPs · Waters ACQUITY Premier + BioAccord/Xevo (intact mass) — Rapid serotype identification and grasp of proteoforms. Sequence detail is complemented by MS/MS
- Native mass spectrometry · Thermo Q Exactive UHMR / native MS configuration — Measures the mass of intact particles/VP complexes. Specialized instrument
- Terminus and sequence confirmation by MS/MS · Thermo Orbitrap (bottom-up/middle-down) — N-/C-terminus and sequence confirmation. Multiple enzymes to maximize coverage
- CGE-LIF / Western blot · SCIEX PA 800 Plus / Progen anti-VP and serotype-specific antibodies — Separation and simple identity confirmation of VP3-related species. Supplements mass spectrometry
Step guide
What you actually do
- Denature, reduce and alkylate the capsid and cut it into peptides with an enzyme such as trypsin
- Separate by reverse-phase LC and acquire MS/MS on a high-resolution mass spectrometer to identify the sequence and the sites of modification
- Measure the intact VPs by LC-MS and confirm the masses and the N-terminal modifications (acetylation and the like)
- Obtain the sequence coverage and the proportion of modification at each site and compare them with a reference lot
What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, the focus is on confirming identity against the known VP sequences. With engineered capsids, serological identification cannot be used, so confirm the sequence of the inserted peptide or mutation site directly by LC-MS/MS peptide mapping, look at the VP mass shift by intact or subunit MS, and verify conformity to design by NGS of the cap gene as needed)
Decision points
- How do you combine intact mass and peptide mapping?
- Intact mass confirms the VP masses for each serotype and the N-terminal processing (removal of the initiator methionine, acetylation). Peptide mapping covers the sequence broadly while identifying post-translational modifications (PTMs) site by site. This two-tier arrangement is commonly adopted as the way to investigate identity and PTMs.
- One digestion enzyme, or several?
- There is an approach of using several enzymes together to raise coverage. It can fill in regions that trypsin alone does not reach. Confirm the grade of the enzymes and the reproducibility of the digestion.
- How do you reflect PTMs in the specification or in in-process monitoring?
- PTMs such as deamidation and oxidation are said to be able to affect delivery efficiency and infectious titer, but which sites matter differs with serotype and function. Establish the range of the proportion at each site across development lots, confirm the relationship with the functional assay, and then decide whether to make them specification or in-process monitoring items.
Common mistakes
- Mistaking oxidation and deamidation introduced during digestion for modifications of the capsid
- Analyzing an engineered capsid against the known serotype sequence as the reference, and missing the insertion site
- Taking the coverage of a single enzyme as comprehensive
Check at your own site
- Is your own PTM range decided from the variability of development lots and its relationship with the functional assay?
- Is matching against the sequence of a known serotype enough for the identity of your own capsid? Or do insertions and mutations have to be confirmed directly?
24Step 24: Infectious titer and potency tests◇ Branches
A mandatory item that measures the ability to actually infect and express, and shows drug product quality and consistency through the vg/IU ratioTropism changes with the modification, so the cell model for potency is re-selected to match the target
Standard methodInfectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)Infectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)
◇ With Engineered capsidTropism changes with the modification, so the cell model for potency is re-selected to match the target◇ With Natural serotypeInfectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)
Details and 4 alternatives
This step coversInfectious titer and potency (infectious titer / potency: the biological activity of infecting cells and expressing the transgene) (infectious titer and potency tests)
A regulatory-required step that measures the biological activity (infectious titer, potency) of "whether it actually infects cells and works."
The measurement uses TCID50 or qPCR/ddPCR endpoint methods. By measuring genome copies after infection, the titer of the particles that truly work is determined.
It also looks at the ratio of the number of infectious particles (IU) to the number of genome-containing particles (vg). This vg/IU ratio is an indicator of the quality and consistency of the drug product.
This is the item that confirms "whether it actually infects cells and works." It is also required by regulation. In addition, the ratio of how many truly infectious particles (IU) there are relative to the number of genome-containing viral particles (vg) is examined to show the quality and consistency of the drug product.
MakersBio-Rad, Molecular Devices, ATCC, BD, Applied Biosystems
Why it is the standard. A representative method for measuring infectious titer that reflects entry into cells and gene delivery. Values are made consistent by normalizing against an AAV2 reference standard or the like.
Check also. Potency in the regulatory sense is a separate concept. A cell-based expression/function assay based on the mechanism of action (MoA) of each product (transgene expression level, enzyme activity, change in cell function, etc.) must be set up separately. Infectious titer and potency are not combined under the same reference method.
◇ With Engineered capsid. Engineered capsids differ from natural ones in receptors and tropism, so general-purpose infectious titer assays such as HEK293 can under- or overestimate. A cell-based potency (transgene expression / function) assay that reflects the target cell type and receptor is designed, and the infectious titer reference strain is also matched to the engineered capsid.
Alternatives in practice
- ddPCR endpoint TCID50 · Bio-Rad QX600 ddPCR — Replaces qPCR with ddPCR for better sensitivity and precision. Makes the infectious titer absolute
- Relative infectivity assay · Cell culture + qPCR/ddPCR (versus reference standard) — Lot-to-lot relative comparison. Consistency control rather than absolute titer
- Cell-based expression potency · Reporter expression (luciferase/GFP) + plate reader/flow cytometry — Functional potency. Reflects the biological activity of the transgene
- vg/IU ratio monitoring · ddPCR (vg) ÷ infectious titer (IU) — An indicator of infection efficiency. Trend control of manufacturing consistency
Step guide
What you actually do
- For infectious titer, plate the cells, add the sample in 10-fold serial dilutions, and culture with helper adenovirus
- After the specified time, lyse the cells and detect the amplified vector genomes by qPCR or ddPCR
- Obtain the 50% infectious endpoint from the distribution of positive wells and calculate the infectious titer (IU/mL)
- For potency, lay out the standard and the sample on the same plate and read the transgene product or a reporter to give the relative potency
What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, general-purpose infectious titer assays based on HEK293 or HeLa lines and their reference strains can be used. Engineered capsids differ from natural ones in receptors and tropism, so a general-purpose system can under- or overestimate. Design a cell-based potency assay that reflects the target cell type and receptor, that is, one that reads transgene expression or function, and match the infectious titer reference strain to the engineered capsid as well)
Decision points
- What do you use as the cell system for infectious titer?
- There are reports that measuring other serotypes in an AAV2-oriented cell system such as RC32 opened up the vg/IU ratio greatly. AAV2 was close to 1, while AAV8 was on the order of several hundred. The denominator of the ratio carries the fit between serotype and assay within it. Choose a cell system that the serotype enters, from receptors and tropism, and confirm the selectivity of the system with negative controls.
- How do you divide the roles of infectious titer and expression potency?
- Infectious titer looks as far as the genome reaching the cell. Expression potency is a layer closer to the mechanism of action, is expressed as a value relative to the standard, and the parallelism of the dose-response curves is confirmed. The closer you get to the mechanism of action, the more the measurement wavers, so the specification range also widens.
- How do you use an infectious titer graduated in 10-fold steps in a specification?
- Because TCID50 is graduated in 10-fold serial dilutions, its resolution is 10-fold. Even a 2-fold difference between lots can come out as the same value. Rather than placing the infectious titer value itself at the center of the specification, it is more reliable to keep measuring with the same system, the same cell bank and the same standard and to look at process consistency from the movement of the ratio.
- Do you assure potency by release testing alone?
- The FDA draft of December 2023 asks that potency be built as an assurance strategy combining process design, process controls, control of raw materials, in-process testing and release testing, rather than relying on release testing alone. What the resolution of the assay cannot reach is filled in by process control.
Common mistakes
- Setting another company's or the literature's vg/IU ratio beside your own value and arguing which is better, even though the systems differ
- Replenishing the standard only after it has run out, so that separate work is needed to show continuity with the data up to then
- Writing a 2-fold control range as the specification for a system graduated in 10-fold steps
Check at your own site
- Does your own infectious titer system match the receptors and tropism of the serotypes and engineered capsids you handle?
- How is your own potency apportioned across process control and control of raw materials, and not release testing alone?
25Step 25: RcAAV detection
Because contamination with replication-competent AAV bears directly on patient safety, this is a safety test required by the FDA and othersBecause contamination with replication-competent AAV bears directly on patient safety, this is a safety test required by the FDA and others
Standard methodInoculate permissive cells (HeLa/HEK293 lines) with the sample in the presence of helper adenovirus, amplify by passaging, then detect by rep/cap-specific qPCRInoculate permissive cells (HeLa/HEK293 lines) with the sample in the presence of helper adenovirus, amplify by passaging, then detect by rep/cap-specific qPCR
EquipmentApplied Biosystems QuantStudio 7 Pro real-time PCR system (Thermo Fisher). CO2 incubator for passage culture (Thermo Heracell VIOS).
ReagentsTaqMan rep/cap-specific primers and probes, helper adenovirus, permissive cell lines (HeLa/HEK293 type), TaqMan Fast Advanced Master Mix (Thermo Fisher).
Details and 2 alternatives
This step coversDetection of replication-competent AAV (rcAAV): a safety test in which replication-competent AAV that may arise during manufacturing is amplified and passaged in permissive cells in the presence of helper adenovirus and detected by serotype-specific qPCR (rcAAV detection)
A safety test that looks for "AAV that multiplies by itself" (rcAAV), which can be born inadvertently during manufacturing. It can arise at low frequency by recombination between RepCap and ITRs.
The detection method brings it out by amplification. Permissive human cells are infected with rAAV and helper adenovirus and passaged multiple times, and whatever grows is watched.
Each passage is screened by serotype-specific qPCR to confirm that the level is below the detection limit. It is a step required by the FDA and is the linchpin of safety.
Replication-competent AAV can arise at low frequency through recombination between RepCap and ITRs, so FDA makes rcAAV testing mandatory for rAAV products. Permissive human cells are infected with rAAV and helper adenovirus and amplified through multiple passages, and each passage is screened by serotype-specific qPCR to confirm that the level is below the detection limit.
MakersBio-Rad, Thermo Fisher, Applied Biosystems
Why it is the standard. Cell amplification + serotype-specific qPCR is the industry standard method for amplifying and detecting low-frequency contamination with rcAAV with high sensitivity, and QuantStudio systems have an extensive GMP validation track record and are suited to specific quantitation of rep/cap sequences.
Alternatives in practice
- Absolute rep/cap quantitation by ddPCR · Bio-Rad QX600 Droplet Digital PCR — Absolute quantitation of rep/cap sequences after amplification. Advantageous for detecting low-level rcAAV
- Infectious titer-based rcAAV functional assay · Permissive cells + serial passage (cytopathic effect / titer measurement) — Evaluates replication competence functionally. Complementary to PCR; sensitivity and duration are issues
26Step 26: Aggregate and particle size evaluation
SEC-MALS separates and quantitates monomers, dimers and aggregates, because aggregation bears directly on efficacy, immunity and safetySEC-MALS separates and quantitates monomers, dimers and aggregates, because aggregation bears directly on efficacy, immunity and safety
Standard methodSEC-MALS (size exclusion chromatography + multi-angle light scattering)SEC-MALS (size exclusion chromatography + multi-angle light scattering)
EquipmentMALS detector (multi-angle light scattering)Differential refractive index (dRI) detectorUV detectorHPLC (SEC column)FFF system (field flow fractionation) Details and 3 alternatives
This step coversDetection and quantitation of aggregates (oligomers to large aggregates) and evaluation of particle size distribution (aggregate and particle size evaluation / SEC-MALS)
A step that evaluates the amount of "aggregates", in which particles have clumped together, and the particle size distribution. Aggregation bears directly on all of AAV's efficacy, the risk of provoking immunity, and safety.
SEC-MALS is used. The sample is first separated by size with size exclusion chromatography and then measured by multi-angle light scattering. Separating first and measuring afterward is the beauty of this method.
This allows monomer, dimer and large aggregates to be separated and quantitated individually. It is a step to accurately capture aggregation that threatens product quality.
Aggregation bears directly on all of AAV's efficacy, the risk of provoking immunity, and safety. That is exactly why accurate measurement is wanted, and what is used here is the MALS method, which measures after first separating by size. With this method, monomer, dimer and aggregates can each be separated and quantified.
MakersAgilent, Waters, Malvern Panalytical, Wyatt, Beckman Coulter
Why it is the standard. After separation, the absolute molecular weight and size of each peak can be determined directly by light scattering. Moreover, large aggregates that SEC (size exclusion chromatography) cannot fully separate can be separated without damage by FFF (flow FFF), which has low shear (the force that tears particles apart). For these reasons it is regarded as the de facto standard method for quantitating aggregates.
Check also. Combining FFF-MALS, AUC and DLS is effective for evaluating large aggregates.
Alternatives in practice
- DLS / MADLS · Malvern Panalytical Zetasizer Ultra (MADLS) — Simple, obtains particle size distribution/aggregation from a small sample. No separation, so resolution of large aggregates is limited
- SV-AUC · Beckman Coulter Optima AUC — Separates and quantitates aggregates by sedimentation coefficient. Low throughput and high analytical expertise required
- Mass photometry · Refeyn SamuxMP — Directly observes dimers/aggregates by single-particle mass distribution. Small sample volume, rapid
Step guide
What you actually do
- Run the sample in an aqueous mobile phase at neutral pH and separate it by size on a SEC column
- Pass the eluate in turn through MALS (multi-angle light scattering), differential refractive index (dRI) and UV detectors
- Obtain the absolute molecular weight and particle size of each peak and give the proportions of monomer, dimer and aggregates
- Separate and measure large aggregates that SEC cannot resolve by field-flow fractionation (FFF)
Decision points
- Is SEC-MALS enough, or do you add FFF?
- In SEC, large aggregates can be retained on the column or broken by shear. Flow FFF applies little shear and is said to separate even large aggregates that SEC cannot resolve without damaging them. Decide according to the size range of the aggregation and whether a particle size distribution is needed.
- How do you use DLS, SV-AUC and mass photometry for different purposes?
- DLS is simple and needs little material, but because it does not separate, its resolution for large aggregates is limited. SV-AUC can separate and quantify aggregates too, but throughput is low. Mass photometry can see dimers and aggregates directly from the mass distribution of single particles and is quick with little material. Use SEC-based methods routinely and complement them with orthogonal methods for characterization.
- How do you counter adsorption in the mobile phase and the flow path?
- AAV readily adsorbs to surfaces at low concentration, and losses on the column and piping also feed through to apparent aggregation. Choose the mobile phase salt concentration, the additives and low-adsorption components by measuring recovery.
Common mistakes
- Reading molecular weight from the SEC elution position and believing a value that is off because of a difference in shape
- Mistaking particles that have dissociated on dilution in the mobile phase for the original state
- Not confirming adsorption to the lines and the column from recovery, and overestimating how little aggregation there is
Check at your own site
- Is your own assessment of aggregates configured so that sizes SEC cannot resolve are not missed?
- Is the recovery of your own SEC-MALS confirmed for each sample?
27Step 27: Particle number, subvisible particle control
SEC-MALS controls absolute particle number and light obscuration controls subvisible particles against USP limits at the same timeSEC-MALS controls absolute particle number and light obscuration controls subvisible particles against USP limits at the same time
Standard methodSEC-MALS (another method of estimating aggregates, molecular weight and particle number)SEC-MALS (another method of estimating aggregates, molecular weight and particle number)
ReagentsAqueous buffer mobile phaseStandard beads for particle size calibration
Details and 3 alternatives
This step coversSimultaneous measurement of particle number (physical titer = total capsid concentration) and particle size, and control of insoluble subvisible particles in the formulation (particle number, subvisible particle control)
A step that measures both the "number" and "size" of particles at the same time and also controls invisible particles. Physical titer (total capsid concentration) and particle size are measured by SEC-MALS.
Particle number (concentration) is the basis for deciding how much vector to administer. This measurement provides the yardstick for dose design.
In addition, for injectables, insoluble invisible particles (subvisible particles) must be kept within USP limits. It is a step that reconciles dose determination with particulate control.
Particle number (concentration) is the basis for deciding how much vector to administer. In addition, for injectables, the amount of invisible insoluble particles (subvisible particles) is required to be kept within USP limits. That is why the 2 are measured together.
MakersAgilent, Yokogawa, Malvern Panalytical, Wyatt, Beckman Coulter
Why it is the standard. SEC-MALS can directly derive the absolute number of particles from the ratio of eluted mass to molar mass. For subvisible particles, on the other hand, light obscuration is specified in USP <788> as the first-choice compendial method.
Check also. It is not an absolute standard for total capsid concentration. Results can deviate with sample purity, concentration, column recovery and serotype, so it is reported alongside and cross-checked with capsid ELISA, MP, NTA and AUC.
Alternatives in practice
- NTA · Malvern Panalytical NanoSight Pro — Number and size distribution by nanoparticle tracking. Effective in the submicron range
- Flow imaging microscopy (FIM) · Yokogawa FlowCam / Halo Labs HORIZON — Morphological identification of subvisible particles. Advantageous for distinguishing air bubbles from protein particles
- Physical titer by DLS/MADLS · Malvern Zetasizer Ultra — Simple evaluation of particle size and concentration. SEC-MALS/particle counters are superior for absolute number
28Step 28: Encapsulated impurity DNA quantitation
DNase-resistant encapsulated DNA is quantitated by qPCR; it cannot be degraded from the outside and is administered, so it is a safety CQADNase-resistant encapsulated DNA is quantitated by qPCR; it cannot be degraded from the outside and is administered, so it is a safety CQA
Standard methodQuantitation of encapsulated DNA by qPCR / ddPCR after DNase treatmentQuantitation of encapsulated DNA by qPCR / ddPCR after DNase treatment
Details and 3 alternatives
This step coversDetection and quantitation of encapsulated impurities (DNase-resistant contaminating DNA such as host cell DNA and plasmid/helper-derived DNA taken up inside the capsid) (encapsulated impurity DNA quantitation)
A step that measures "DNA taken up inside" the capsid. Encapsulated DNA cannot be degraded even by nuclease treatment from the outside.
The targets are host cell DNA and plasmid/helper-derived DNA. After DNase treatment, qPCR/ddPCR quantitates only the encapsulated DNA that survives.
Because this is administered to the patient as it is, it is a CQA governing safety. Free DNA below 10 ng per 1 dose and fragment length of roughly 200 bp or less are controlled as the guide.
DNA that has been taken up inside the capsid cannot be degraded from the outside even by nuclease treatment. It will be administered to the patient as it is, so it is treated as a critical quality attribute (CQA) that governs safety. That is why regulations also require its control. Specifically, free DNA not enclosed in the capsid is kept below 10 ng per 1 dose, and fragment length is also guided to be roughly 200 base pairs (bp) or less.
MakersBio-Rad, Merck, Illumina, PacBio, Applied Biosystems
Why it is the standard. Residual host cell DNA is an item whose control is required by ICH and the pharmacopoeias. qPCR is established as the standard method for quantitation. Moreover, by measuring the DNase-resistant fraction, only the portion encapsulated in the capsid can be captured separately.
Check also. DNase is a pretreatment, not a measurement method. Routine quantitation is qPCR/ddPCR after DNase treatment; characterization that looks at origin, fragment length and unknown contamination is NGS / long-read NGS. Residual host cell DNA is generally referenced at below 10 ng/dose and below about 200 bp, but for cell substrates of tumorigenicity concern such as HEK293/293T, stricter control may be required depending on product risk (the source is the FDA's "Characterization and Qualification of Cell Substrates and Other Biological Materials Used in the Production of Viral Vaccines for Infectious Disease Indications," February 2010, and WHO recommendations on cell substrates; this is not gene therapy CMC guidance).
Alternatives in practice
- Absolute quantitation of encapsulated HCDNA by ddPCR · Bio-Rad QX600 ddPCR — No standard curve needed, quantitates low levels with high precision. Lower CV than qPCR
- Encapsulated contaminating DNA by NGS · Illumina NextSeq 2000 (short-read) / PacBio Revio (long-read) — Covers the types and distribution of encapsulated nucleic acids comprehensively. PCR is better for quantitation
- Commercial residual HCDNA quantitation kit · Thermo resDNASEQ HEK293 (qPCR) — Comes with standardization and regulatory documentation. Reduces design effort
Step guide
What you actually do
- Treat the sample with DNase (or Benzonase) to digest free DNA outside the capsids and inactivate the enzyme
- Break the capsids with proteinase K or similar and extract the nucleic acids left inside
- Run qPCR or ddPCR with primers and probes against the host repeat sequences (18S, Alu and the like) and against plasmid- and helper-derived sequences
- Convert to the quantity per dose from a standard (host genomic DNA) or by absolute quantitation
Decision points
- How do you separate the control of encapsidated DNA from DNA outside the capsid (residual DNA)?
- DNA on the outside can be removed by nuclease treatment and purification, so it can be controlled as a performance attribute of the process. DNA on the inside is settled at the moment the particle forms, so it can only be moved by upstream design. Unless a method for measuring outside and inside separately is established first, the cause cannot be identified when the value moves.
- How do you set a reference point for the specification?
- For free host DNA, the thinking presented by the FDA (2010) and the WHO for vaccine cell substrates, of 10 ng or less per dose with fragments of roughly 200 bp or less, is sometimes referred to. There is no agreed figure for applying this to DNA inside the capsid, and because AAV doses are orders of magnitude higher, it is discussed item by item. Follow what has been agreed with the authorities and the approved specification.
- qPCR, ddPCR, or NGS?
- qPCR is widespread as the standard method. ddPCR needs no standard curve, can quantify low amounts with high precision and is said to have a low CV. NGS can find unexpected sequences comprehensively, but PCR is better for quantitation. Combine them according to the purpose of the measurement (total quantity or breakdown).
- How do you confirm the capsid digestion conditions and the recovery?
- If the treatment is insufficient the DNA inside does not come out, and if it is excessive the DNA itself is broken. Confirm the recovery of the sample preparation with a spike-recovery test using a known amount of DNA.
Common mistakes
- Watching only the total quantity and not tracking the breakdown (the origin, such as the resistance gene)
- The capsid digestion conditions are insufficient, so the DNA inside does not come out and the amount is underestimated
- Carrying another company's or the literature's specification values over to your own product without assessing the item's dose and risk
Check at your own site
- Has your own encapsidated DNA a method established for measuring outside and inside separately?
- Is your own residual DNA specification set in a form agreed with the authorities, taking the item's dose into account?
29Step 29: Residual host-derived impurities: DNA/HCP
Quantitates residual host DNA, plasmid and HCP and keeps oncogenic and immune risk within FDA/WHO limitsQuantitates residual host DNA, plasmid and HCP and keeps oncogenic and immune risk within FDA/WHO limits
Standard methodResidual host cell DNAResidual host cell DNA
Details and 4 alternatives
This step coversResidual host-derived impurities (residual host cell DNA / residual plasmid and helper sequences / host cell protein HCP) (residual host-derived impurities: DNA/HCP)
A step that measures, all together, the "host-derived impurities left over" that purification could not fully remove, and shows conformance to specifications.
The targets are 3: residual host cell DNA, plasmid/helper sequences and host cell protein (HCP). All lead to risks of oncogenicity and immunogenicity.
That is why they are confirmed after being removed thoroughly. It is shown that FDA/WHO limits are met, such as free residual DNA below 10 ng per 1 dose and fragment length of roughly 200 bp or less.
Residual host-derived impurities are critical quality attributes that govern safety. Specifically, they are host cell DNA, plasmid- and helper-derived sequences, and host cell proteins (HCP). They lead to risks of oncogenicity and immunogenicity, so after careful removal, it is shown that the limits set by the FDA and WHO are met. For example, free residual DNA is kept below 10 nanograms per 1 dose, and fragment length at roughly 200 base pairs or less.
MakersBio-Rad, Bio-Techne, Molecular Devices, Cygnus Technologies, Techne
Why it is the standard. qPCR and ddPCR (18S/Alu), which are established methods, are used to quantitate residual DNA. Of these, ddPCR allows absolute quantitation and is superior in precision and CV. The Cygnus F650S 3G kit is used for HCP analysis. This is recognized in the industry as the reference method for analysis of HEK293-derived HCP and has obtained regulatory approval worldwide in multiple commercial cell products and gene therapies. The criteria for conformance follow the FDA/WHO limits (free residual DNA <10 ng/dose, fragments <~200 bp, etc.).
Check also. Residual host cell DNA is generally referenced at below 10 ng/dose and below about 200 bp, but for cell substrates of tumorigenicity concern such as HEK293/293T, stricter control may be required depending on product risk (the source is the FDA's "Characterization and Qualification of Cell Substrates and Other Biological Materials Used in the Production of Viral Vaccines for Infectious Disease Indications," February 2010, and WHO recommendations on cell substrates; this is not gene therapy CMC guidance).
Alternatives in practice
- Fluorescent dye (PicoGreen-type) total DNA · Thermo Quant-iT PicoGreen + plate reader — Simple quantitation of total double-stranded DNA. Not sequence-specific, for screening
- Mass spectrometry proteomics · Thermo Orbitrap (HCP identification/quantitation) — Identifies individual HCP species. Complements hard-to-detect HCPs that ELISA misses
- Digital/qPCR for residual plasmid and adenovirus helper · Bio-Rad QX600 / QuantStudio — Individually quantitates plasmid/helper-derived sequences
- Evaluation of replication-competent AAV · rep/cap qPCR/ddPCR + functional assay — Monitors rcAAV as well. Complements the safety profile
Step guide
What you actually do
- Extract DNA from the sample and quantify host sequences such as 18S and Alu by qPCR or ddPCR, with HEK293 genomic DNA as the standard
- Measure plasmid- and helper-derived sequences with separate primers and probes
- Measure the amount of host cell protein by an HCP ELISA for HEK293
- Measure the residual amount of enzymes added in the process, such as the nuclease, and record the results against the specification
Decision points
- How do you confirm the coverage of the HCP ELISA?
- Commercial HCP ELISA kits for HEK293 come with the maker's statement of antibody coverage, but confirmation with samples from your own process is needed separately. The HCP composition of the samples changes at each stage of the process, so one approach is to confirm the coverage by an orthogonal method such as mass spectrometry.
- Do you identify individual HCP species by mass spectrometry?
- Some HCPs are hard to see by ELISA, and identifying individual species by LC-MS complements it. Consider this when there is concern about whether a high-risk HCP remains.
- With what do you measure residual DNA?
- Both qPCR and ddPCR are used, and ddPCR, being absolute quantitation, is said to be the more precise. The recovery of the sample preparation (DNA extraction) moves the result, so include confirmation of recovery in the procedure.
- How do you set the residual DNA specification?
- For free residual DNA, the thinking presented by the FDA (2010) and the WHO for vaccine cell substrates, of 10 ng or less per dose with fragments of roughly 200 bp or less, is referred to. It is not a figure that applies to AAV as it stands. For AAV, the origin (host, plasmid, helper) is also at issue in addition to quantity and size. Follow the approved specification and what has been agreed with the authorities.
Common mistakes
- Judging that HCPs have been sufficiently removed from the ELISA figure alone, without confirming coverage
- Not looking at extraction recovery, and mistaking a value that moved because of a difference in sample preparation for a difference in the process
- Dropping the item for measuring residual added enzymes such as the nuclease from the specification plan
Check at your own site
- Has your own HCP ELISA had its coverage confirmed with your own process samples?
- For your own impurity removal, is the contribution of each stage measured, so that you know which step removes what?
30Step 30: Residual plasmid DNA quantitation
Encapsulated and free residual plasmids are manufacturing-derived genotoxic impurities that should be controlled separately from host DNAEncapsulated and free residual plasmids are manufacturing-derived genotoxic impurities that should be controlled separately from host DNA
Standard methodqPCR/ddPCR comparing with and without DNase treatment to distinguish plasmid encapsulated in capsids from free plasmid, targeting rep, cap, KanR and similar sequencesqPCR/ddPCR comparing with and without DNase treatment to distinguish plasmid encapsulated in capsids from free plasmid, targeting rep, cap, KanR and similar sequences
EquipmentBio-Rad QX600 Droplet Digital PCR System (comparison of ± DNase treatment distinguishes encapsulated from free plasmid).
Reagentsrep/cap/kanamycin resistance gene-specific primers and probes, Bio-Rad ddPCR Supermix for Probes, Merck Benzonase / DNase I (removal of free plasmid).
Details and 2 alternatives
This step coversQuantitation of residual plasmid DNA: residual plasmids from triple transfection (RepCap / AdHelper / kanamycin resistance gene, etc.) are quantitated by qPCR/ddPCR and controlled by a specification separate from host cell DNA (residual plasmid DNA quantitation)
A step that measures the "leftover plasmids" from triple transfection. A large amount of plasmid is put in with transient delivery, and its fragments can remain.
The targets are RepCap, AdHelper, kanamycin resistance gene and so on. Results with and without DNase treatment are compared to quantitate separately those encapsulated in capsids and those that are free.
These differ in origin from host cell DNA, so they are controlled as an independent specification. It is a quantitation targeting rep, cap, resistance genes and the like that is essential for safety and specifications.
In transient transfection a large amount of plasmid is put in, and its fragments can be encapsulated in the capsid or remain as free impurities, so quantitation of residual plasmid targeting rep/cap/antibiotic resistance genes and the like, independent of host cell DNA ([25]), is essential for safety and specifications.
MakersBio-Rad, Merck, Illumina, PacBio, Applied Biosystems
Why it is the standard. ddPCR can absolutely quantitate low-concentration residual plasmid sequences with high precision without depending on a standard curve, and combined with DNase treatment can separate encapsulated from free, so it is the working standard suited to specification control of manufacturing-derived DNA impurities.
Alternatives in practice
- Real-time qPCR · Applied Biosystems QuantStudio 7 Pro + TaqMan Master Mix — Quantitates rep/cap/antibiotic resistance genes. CV is larger than ddPCR but widely available
- Profiling of encapsulated nucleic acid impurities by NGS · Illumina NextSeq 2000 / PacBio Revio — Covers the sequence and distribution of encapsulated contaminating nucleic acids comprehensively. PCR is better for quantitation
Step guide
What you actually do
- Split the sample in two, treating one with DNase and leaving the other untreated
- Break the capsids, extract the nucleic acids, and run ddPCR or qPCR with primers and probes against targets such as rep, cap and the kanamycin resistance gene
- From the difference between treated and untreated, quantify plasmid encapsidated in capsids separately from free plasmid
- For each target, convert to the quantity per dose and record it against the specification
Decision points
- Which sequences do you target?
- Among the sequences in the backbones of RepCap, AdHelper and the transgene plasmid, choose mainly those that attract regulatory attention, such as the resistance gene. The nature of the risk differs by origin, so decide the number of targets and the sensitivity from risk assessment.
- ddPCR, or qPCR?
- ddPCR does not depend on a standard curve, can give absolute quantitation of low-concentration sequences with high precision, and suits comparing with and without DNase treatment to separate encapsidated from free material. qPCR is widespread but tends to have a larger CV than ddPCR.
- Do you set the specification separately from host DNA?
- Because the origin differs and the nature of the risk differs too, one approach is to control the specification independently of host DNA. How the specification is set follows what has been agreed with the authorities and the approved plan.
- Do you add comprehensive confirmation by NGS?
- Short-read and long-read sequencing can be used to investigate the types and distribution of encapsidated nucleic acids comprehensively. PCR is better for quantitation; sequencing is strong at finding unexpected sequences.
Common mistakes
- Not comparing with and without DNase treatment, and judging on the total quantity without distinguishing encapsidated from free material
- Not aligning the resistance gene quantitation method with the incoming testing stage for the raw plasmid, so that origin cannot be traced
- Loose control of the assigned value of the standard plasmid, so that calibration drifts between lots
Check at your own site
- Is your own residual plasmid set as a specification separate from host DNA?
- Is your own resistance gene quantitation method aligned on the same target as the incoming test for the raw plasmid?