Gene therapy Process map

AAV vectors

This reference process map organizes the manufacture and analysis of AAV vectors in the order of upstream → downstream (purification) → formulation and fill-finish → characterization. The optimal method depends on conditions such as serotype and producer cells, so each step, starting with empty/full capsid separation, also lists alternative and complementary methods.

Editor's note. Transient triple transfection remains the reference because swapping plasmids is all it takes to change the serotype and the transgene, with no need to rebuild the manufacturing process. In early development, where there is no time to wait for a stable producer line to be established, this flexibility counts for more than anything. Technology transfer usually stumbles when optimization of the transfection reagent and plasmid ratio is taken lightly, and these directly govern yield and the full fraction. And the real contest is in the AEX polishing for empty/full separation. What decides drug substance quality and titer, and by extension dose design, is not the absolute amount of full capsids but how well the empties are removed, so the trade-off between taking resolution at the expense of recovery and the opposite is the heart of process design.

Made fromPlasmid DNA (3 plasmids: GOI / RepCap / AdHelper)

At a glance

Select a step to jump to its card. ◇ marks a step whose standard method changes with the condition.

  1. Cells and production7 steps
    1. Cell bank preparation and cryopreservation
    2. Cell bank characterization and safety testing
    3. Raw material plasmid receipt and qualification
    4. Seed train, N-1 scale-up
    5. Production platform selection
    6. Transfection reference method
    7. Perfusion, process intensification
  2. Purification6 steps
    1. Harvest, cell lysis
    2. Nuclease treatment, clarification
    3. Capture purification (changes with the condition)
    4. Empty / full separation polishing step (changes with the condition)
    5. UF/DF, 0.2 µm filtration
    6. Final sterile filtration
  3. Formulation and fill-finish4 steps
    1. Fill-finish, aseptic filling
    2. Formulation, formulation design
    3. Frozen storage of drug substance
    4. Cold chain transport
  4. Characterization13 steps
    1. Vector genome titer (ddPCR)
    2. Total capsid titer, full (changes with the condition)
    3. Empty
    4. Genome integrity (CGE-LIF)
    5. VP1:VP2:VP3 ratio (CE-SDS)
    6. Capsid identification, PTM analysis (LC-MS) (changes with the condition)
    7. Infectious titer and potency tests (changes with the condition)
    8. RcAAV detection
    9. Aggregate and particle size evaluation
    10. Particle number, subvisible particle control
    11. Encapsulated impurity DNA quantitation
    12. Residual host-derived impurities: DNA/HCP
    13. Residual plasmid DNA quantitation

Cells and production(7 steps)

Step 1: Cell bank preparation and cryopreservation

Two-tier MCB/WCB storage, slow freezing and vapor-phase liquid nitrogen storage are the starting point that assures manufacturing reproducibilityTwo-tier MCB/WCB storage, slow freezing and vapor-phase liquid nitrogen storage are the starting point that assures manufacturing reproducibility

Details and 3 alternatives

This step coversConstruction, cryopreservation and storage of HEK293 MCB/WCB (preparation and long-term storage of a two-tier cell bank system) (cell bank preparation and cryopreservation)

A step that makes the "seed stock" of cells that is the starting point of AAV manufacture, freezes it and keeps it ready. It is stored in two tiers, master (MCB) and working (WCB), and cells are taken from the WCB for each manufacture.

After dispensing uniformly into each vial, the cryoprotectant DMSO is added at a final 10% and the cells are frozen slowly at about 1 °C per minute. This rate, which does not damage the cells, is the key, and they are finally laid to rest for a long time at −130 to −150 °C in the liquid nitrogen vapor phase.

The aim is reproducibility. Only when vials are uniform, frozen without damage and kept stable at ultra-low temperature can lots years later be started up with the same quality.

In AAV manufacturing, cells are stored in 2 tiers, an MCB (master) and a WCB (working), and cells are taken from the WCB for each manufacture. Reproducible manufacturing requires 3 things: dispensing vials uniformly, freezing slowly so the cells are not damaged, and keeping them stable for a long time at ultra-low temperature. Cells are frozen with DMSO added at a final 10%, cooled slowly at about 1 °C per minute, and stored in the vapor phase of liquid nitrogen (roughly −130 to −150 °C).

MakersCytiva, Sartorius, Eppendorf, Corning, BioLife Solutions

Why it is the standard. The two-tier cell bank (MCB/WCB) and confirmation of suitability by characterization are set out in ICH Q5D. The conditions of adding about 10% DMSO and freezing slowly at about 1 °C per minute are an established way to suppress ice crystal formation, and agree with the standard protocols of Sigma-Aldrich, Thermo Fisher, Corning and others. Long-term storage in the vapor phase of liquid nitrogen (−130 °C or below, a temperature below the glass transition point) minimizes the decline in viability. Controlled-rate freezing and vapor-phase liquid nitrogen storage have become standard practice for GMP cell banks.

Alternatives in practice

  • Passive freezing · Thermo Scientific Mr. Frosty Nalgene 5100 (isopropanol type) or CoolCell (Corning) — Small scale, small MCB quantities. Simple control at about -1 °C/min. A controlled-rate freezer is recommended for GMP batches
  • Mechanical ultra-low temperature storage · -86 °C ULT freezers (Thermo Scientific TSX / Eppendorf CryoCube / PHCbi VIP ECO) — Intermediate, short-term storage. Not below the glass transition point, so LN2 vapor phase is safer for long-term storage
  • DMSO-free / low-toxicity freezing · CryoStor CS2/CS5 (BioLife Solutions) or trehalose / polysaccharide-based media (Sigma-Aldrich) — When DMSO toxicity is a concern. Protocol revalidation is needed

Step guide

What you actually do

  1. Check the viability and cell count of the pre-cultured HEK293 and suspend them uniformly in freezing medium (containing DMSO)
  2. Dispense the set volume into each cryovial and record the number of vials, the lot number and the storage location
  3. Arrange the vials in the controlled-rate freezer and run a program that cools at about 1 °C per minute to freeze them
  4. Immediately after freezing, transfer them to the liquid nitrogen vapor-phase tank and register the rack position in the inventory log
  5. When raising a WCB from the MCB, thaw 1 vial, culture it to the set passage number, then dispense and freeze it by the same procedure

Decision points

Use a controlled-rate freezer, or make do with a simple freezing container?
If you are only making a small MCB at the research stage, one option is to approximate about 1 °C per minute with a simple container such as an isopropanol type. For GMP banks a controlled-rate freezer is often chosen, since it leaves a record of the cooling and shows little difference by vial position, and the cooling profile you use is decided by measuring post-thaw viability with your own cells.
Liquid nitrogen vapor-phase storage, or mechanical ultra-low temperature storage?
For long-term banks, the liquid nitrogen vapor phase, which can hold a temperature below the glass transition point, is often chosen. Mechanical storage at around −80 °C is not below the glass transition point, so it is regarded as suitable for intermediate or short-term storage. Liquid nitrogen fails when supply is interrupted and mechanical units when power is lost, so which fails first is decided by looking at your own facility.
Can a freezing medium with a lower DMSO concentration be used?
Lowering DMSO eases toxicity to the cells, but it also weakens protection against ice crystals and calls for the cooling profile to be reviewed and revalidated. The maker's freezing data and the post-thaw viability and growth with your own cells are confirmed separately.
How do you decide the number of MCB and WCB vials and where to keep them?
Because an MCB is hard to remake, one approach is to assume it will not be drawn down and to split it between a separate store or a separate site. For the WCB, the number of vials needed is worked back from the number of manufacturing runs and the number of replenishments.

Common mistakes

  • Culture before freezing drags on, the passage number advances, and you end up having to shorten the cell age limit afterwards
  • Deciding the profile without measuring the temperature distribution inside the chamber, even though cooling differs with vial position
  • Labels become unreadable in the vapor phase and the history of a single vial can no longer be traced

Check at your own site

  • Can your own bank show in its records that all vials were frozen from the same population under the same conditions?
  • In your own storage, which fails first, power or nitrogen supply, and is the place to move the vials to decided for when it fails?

Step 2: Cell bank characterization and safety testing

Sterility, mycoplasma, identity, adventitious viruses and genetic stability support the qualification of the cell bankSterility, mycoplasma, identity, adventitious viruses and genetic stability support the qualification of the cell bank

Details and 4 alternatives

This step coversCharacterization and safety testing of MCB/WCB (sterility, mycoplasma, identity, adventitious viruses, genetic stability) (cell bank characterization and safety testing)

A testing step that supports whether the frozen seed stock (MCB/WCB) "can really be used for manufacturing." Without passing this, the production that follows cannot proceed.

There are two axes to confirm. One is cleanliness: whether sterility, mycoplasma and externally introduced viruses are absent. The other is identity: confirming in line with ICH Q5D that the cells are indeed the intended HEK293 line.

Genetic stability is also evaluated. This step serves to assure the identity and cleanliness of the cells before upstream is started.

To support that the cell banks (MCB/WCB) can be used for manufacturing, 2 things must be confirmed. The 1st is "cleanliness": whether anything other than the host has crept in, and whether any externally introduced virus is mixed in. The 2nd is "identity": confirming that the cells are indeed the intended cell line. This is the idea required by ICH Q5D. When making a gene therapy vector such as AAV, the vector is produced in cells called HEK293. For this cell bank, tests of sterility, mycoplasma, identity, adventitious viruses and genetic stability are imposed as regulatory requirements. The content of each test is determined in line with ICH Q5A(R2) and Q5B and the pharmacopoeias of each region (US, Europe, Japan).

MakersMerck, Sartorius, ATCC, Illumina, Roche

Why it is the standard. For the mycoplasma test, the reference is to combine the culture method with the method that uses indicator cells (28 days), and NAT (nucleic acid amplification) is positioned as an alternative method after validation. The applicable standards are USP <63>, Ph. Eur. 2.6.7, the JP and 21 CFR 610.30. For identification of whether a cell line is the intended one, the STR method is the reference, and ATCC ASN-002 standardizes it as an identification method for human cell lines. For adventitious viruses, ICH Q5A(R2) requires characterization at 3 points, MCB, WCB and EOP, and specifies a 28-day in vitro test with a second-week passage added. For genetic stability, ICH Q5B/Q5D require evaluation at 2 time points, MCB and EOP.

Alternatives in practice

  • Mycoplasma NAT · Roche MycoTOOL / Thermo Fisher MycoSEQ Real-Time PCR Detection Kit (QuantStudio) — Rapid compared with the 28-day culture method. Pharmacopoeial alternative-method validation is needed
  • Adventitious viruses (NGS / in vitro) · Metagenomic NGS with Illumina NextSeq 2000, or in vitro indicator cell assay compliant with 9 CFR / Ph. Eur. — Complements TEM and indicator cells. NGS for broad-spectrum detection
  • Cell identification · STR (AmpFLSTR) + isozyme analysis, or SNP array (Thermo Fisher Axiom) — Detects mix-ups of human lines. STR is the standard
  • Genetic stability · Karyotyping (G-banding) + NGS (Illumina) for passage stability confirmation — Comparison of MCB/WCB/EOPC. Confirmation of copy number and insertion site

Step guide

What you actually do

  1. Pull test vials from the bank and send them as samples for each test item to the testing laboratory or contract organization
  2. Perform sterility testing and mycoplasma testing by a pharmacopoeial culture method or a validated nucleic acid amplification technique (NAT)
  3. Confirm by STR profiling and the like that the cells are the intended HEK293 line and that there is no mix-up with another cell line
  4. Examine for the presence of adventitious viruses using indicator cell tests, electron microscopy and, where needed, next-generation sequencing (NGS)
  5. Compare the MCB with cells at the end of production (EOP) and evaluate genetic stability

Decision points

Keep the testing in house, or send it to a contract organization?
Adventitious virus testing is the heaviest group of tests for products derived from animal cells and requires indicator cells and dedicated facilities. A common arrangement is to send it to a specialist contract organization while keeping routine tests such as sterility, mycoplasma and identity in house. If you send it out, agree the validation of the test methods and the format of the reports in advance.
Clear mycoplasma by the culture method, or use NAT?
The culture method takes 28 days to a result, but for samples such as a bank, where there is time to spare, one option is to combine the broadly covering culture method with the indicator cell method. NAT gives a result in a short time, but you need to settle its validation as an alternative to the pharmacopoeial method and how to handle the fact that it does not distinguish live from dead.
Change the scope of testing between the MCB and the WCB?
The arrangement generally adopted is to concentrate the heavy evaluation of adventitious agents on the MCB and to confirm mainly sterility, mycoplasma and identity on the WCB. The scope is designed from risk in line with ICH Q5D and Q5A(R2) and follows what has been agreed with the regulatory authorities.
For genetic stability, cells from which time points are compared?
Under the thinking of ICH Q5B and Q5D, 2 time points are compared: the MCB and the end of production (EOP). Cells cultured to the maximum passage number assumed in manufacturing have to be prepared in advance.

Common mistakes

  • Building the bank without allowing for the number of vials the testing needs, leaving too few vials for retesting
  • Accepting the bank without deciding the procedure for following up a NAT positive by the culture method, so that the decision takes time
  • Not collecting cells at the end of production, so that the comparison for genetic stability can no longer be made afterwards

Check at your own site

  • In your own bank testing, which items are assigned to the MCB and which to the WCB in the approved plan?
  • Does your own mycoplasma testing have the number of days to a result built into the seed train schedule?

Step 3: Raw material plasmid receipt and qualification

The plasmid is the starting material that becomes the product DNA itself, and its quality directly governs titer and safetyThe plasmid is the starting material that becomes the product DNA itself, and its quality directly governs titer and safety

Standard methodTopology by agarose gel electrophoresis / CGETopology by agarose gel electrophoresis / CGE
EquipmentCGE topology analysis: Agilent 5200 Fragment Analyzer (dsDNA separation capillary array). Endotoxin: Charles River Endosafe nexgen-PTS (cartridge-type LAL). Agarose gel: Bio-Rad Sub-Cell GT system + ChemiDoc.
ReagentsAgilent Fragment Analyzer dsDNA 915 Reagent Kit (separation gel, size marker, intercalating dye). Endosafe LAL cartridges (Charles River, sensitivity 0.05–5 EU/mL). Plasmid standard (in-house reference). Agarose, TAE/TBE buffer.
Details and 3 alternatives

This step coversReceipt and qualification of plasmid DNA (GOI / RepCap / AdHelper) as raw material: the 3 GMP plasmids that are the starting materials for transfection are tested for purity, supercoiled fraction, ITR integrity and residual impurities (host DNA / RNA / endotoxin / antibiotics) to make the acceptance decision (raw material plasmid receipt and qualification)

A step that receives the 3 plasmids (gene of interest, RepCap, AdHelper), the "blueprints" to be put into the cells, as raw material and judges their quality. It inspects the starting material of manufacturing itself.

In addition to purity, supercoiled fraction (usually 80% or more) and ITR integrity, residual impurities such as host DNA, RNA, endotoxin and antibiotics are tested to decide pass or fail.

If this is lax, it bears directly on the later full capsid ratio, titer and genotoxicity risk. That is why suitability as a starting material is confirmed strictly.

In transient triple transfection, the 3 plasmids define the AAV genome, capsid and production, so a low supercoiled fraction (usually 80% or more) or poor ITR integrity bears directly on the full capsid ratio, titer and genotoxicity risk. This is a standard step to confirm suitability as a starting material, based on USP <1040> and others.

MakersBio-Rad, Agilent, Charles River, PacBio, Oxford Nanopore

Why it is the standard. Fragment Analyzer-type CGE can quantitate the supercoiled / open circular / linear ratio of plasmids with high resolution, and Endosafe PTS enables rapid, GMP-compatible endotoxin quantitation in a cartridge format, so they are widely adopted as the actual operating standard for starting-material qualification.

Alternatives in practice

  • Anion-exchange HPLC topology · Thermo Scientific DNAPac PA200 / Agilent 1290 Infinity II Bio LC + AEX column — Quantitative separation of supercoiled / open circular / linear. Complementary to CGE
  • Quantitation of residual host DNA and kanamycin resistance gene · Bio-Rad QX600 Droplet Digital PCR System — Absolute quantitation of host DNA and antibiotic resistance genes by ddPCR
  • NGS confirmation of ITR / full-length sequence · Confirmation of full length and ITR integrity with PacBio Revio (HiFi long reads) or Oxford Nanopore — Long reads for confirming the ITR hairpin structure. Short reads for mutation detection

Step guide

What you actually do

  1. Accept the material by comparing the supplier's CoA (certificate of analysis), lot number and the temperature record during transport with the purchase specification
  2. Pull a sample and measure the proportions of the supercoiled, open circular and linear forms by capillary electrophoresis or HPLC
  3. Measure residual DNA and RNA from the host E. coli, endotoxin and the antibiotic resistance gene
  4. Confirm by sequence and restriction fragment patterns that the ITRs (inverted terminal repeats) are not damaged
  5. Store released lots under the set conditions and record the quantity used and the quantity remaining

Decision points

Rely on the supplier's CoA, or retest every item in house?
If supplier management is in place and the CoA test methods have been evaluated, incoming testing may be narrowed to identity and the main items. For items that bear directly on titer and safety, such as ITR integrity and supercoiled content, confirming them in house or at an independent testing laboratory is a common choice. How far you rely on the supplier follows the results of the supplier audit and the risk assessment.
How is the acceptance criterion for supercoiled content decided?
Plasmid topology (form) is said to affect the full fraction and the titer. The figures are decided from experience with each item and from risk assessment, set by working back from the downstream requirements rather than taking values from other companies or the literature.
By which method is ITR integrity examined?
The ITRs are GC-rich hairpin structures and are hard to read by short-read sequencing. One approach is to confirm them by orthogonally combining methods with different detection power, such as long-read sequencing and restriction fragment patterns.
How far is the residual antibiotic resistance gene measured?
The resistance gene in the backbone of the transgene plasmid is a sequence that attracts particular regulatory attention. Aligning the specification and the measurement method for residual plasmid in the product lets you trace the origin of carryover in later lots.

Common mistakes

  • Merely transcribing the CoA values without confirming that they can be reproduced by your own analytical methods
  • Judging ITR integrity by short-read sequencing alone and missing a deletion in the hairpin region
  • Not thinking about switching lots until the plasmid stock is nearly exhausted, so that qualification of the new lot is not ready in time

Check at your own site

  • Are your own plasmid acceptance criteria set by working back from the downstream full fraction and the residual plasmid specification?
  • How far does your own supplier disclose the plasmid manufacturing records and change notifications?

Step 4: Seed train, N-1 scale-up

A seed train that aligns viability, density and cell age immediately before transfection and supplies the production vesselA seed train that aligns viability, density and cell age immediately before transfection and supplies the production vessel

Details and 4 alternatives

This step coversBuilding the seed train for suspension HEK293 and N-1 → N scale-up (supplying cells from seed culture to the production bioreactor) (seed train, N-1 scale-up)

A "run-up" step in which cells are revived from a frozen stock and expanded stepwise to a quantity that can be sent to the production vessel. They are supplied from the seed culture (seed train), through the N-1 vessel, to the N production bioreactor.

The cells used are HEK293 adapted to serum-free suspension culture, carrying the adenovirus-derived E1 region that supports virus production. They are bridged to the next vessel while being expanded.

The contest is in preparing the state just before transfection. Viability, the intended cell density and an appropriate cell age, these three, are aligned so that cells in good condition are delivered to the production vessel.

The producer cells used in AAV manufacturing are HEK293 cells adapted to grow in suspension. They carry the adenovirus-derived E1 region, which supports virus production. Immediately before the operation that introduces genes into these cells (transfection), 3 conditions must be aligned: the cells are well viable, they are at the intended concentration (density), and they are at an appropriate cell age, neither too young nor too old. To send cells to the N production vessel in this state, the seed cells are expanded step by step. Specifically, the reference approach is to start from shake flasks and enlarge the vessel in stages to a small bioreactor and then a single-use bioreactor (SUB). So that the culture environment does not shift as the vessel gets bigger, a practice has been established of scaling up while keeping the equipment geometry matched, such as holding the agitation power per unit volume (P/V) constant at each stage.

MakersCytiva, Sartorius, Repligen, Eppendorf, Corning

Why it is the standard. Culturing suspension HEK293 in stirred tanks (SUB) is the industry standard for commercial AAV manufacturing. The reference values are reported consistently in manufacturers' technical documents and peer-reviewed papers (Grieger 2016 and others). Viable cell density (VCD) at transfection is 1–2×10^6 cells/mL with viability above 95%. Seed maintenance is passaged 2–3 times a week at 0.25–0.5×10^6 cells/mL, and seeding into the SUB is at 0.35–0.9×10^6 cells/mL. Scale-up keeps P/V (agitation power per unit volume) constant.

Alternatives in practice

  • High-cell-density seed train by perfusion · Repligen XCell ATF 6 / KrosFlo TFDF + Sartorius Biostat STR — N-1 concentration allows the production culture to start at a high inoculation density. Shortens production time
  • Orbital shake expansion · Kuhner SB10-X / Thermo Scientific shakers (large flasks, wave motion) — Simple but the upper scale limit is small. Suitable for the stage before the SUB
  • Expansion on microcarriers (adherent system) · Cytiva Cytodex / Corning microcarriers + SUB — When adherent HEK293T is used. For lines that are difficult to adapt to suspension
  • Benchtop rigid-vessel STR · Sartorius Biostat B / Eppendorf BioFlo 320 (glass vessel) — Process development and condition optimization. Obtains correlation with the SUB

Step guide

What you actually do

  1. Thaw 1 vial of the WCB, inoculate a shake flask with serum-free medium, and passage the cells while confirming their recovery
  2. Expand from flasks to small bioreactors and single-use bioreactors (SUB), raising the volume stepwise
  3. Measure viable cell density and viability daily, record doubling time and metabolites as well, and judge whether the culture may be moved to the next stage
  4. Grow the cells to the target density in the N-1 vessel and transfer them to the production vessel (N vessel) at the set seeding density

Decision points

How many stages do you use, and how do you run the N-1 vessel?
The number of stages is set by both the expansion ratio and the turndown ratio of the vessels (the minimum working volume). Whether the N-1 is run in batch mode or at high density by perfusion to raise the seeding density of the production vessel is chosen by balancing the number of days the equipment is occupied against the cell age limit.
What decides the pass conditions for handing over to the next stage?
Viable cell density alone is not enough; viability, doubling time and metabolites such as lactate are reviewed alongside it. The literature and maker documents include examples showing a viable cell density at transfection of 1–2×10⁶ cells/mL and viability above 95%. Vary the conditions with your own cell line, medium and production system and fix your own ranges.
In scale-up, which condition is kept the same as you expand?
The approach used is to keep the agitation power per unit volume (P/V) the same. However, oxygen transfer and mixing time also change with vessel geometry, so the conditions from a small vessel do not necessarily carry straight over to a large one. Establish the correlation with a scale-down model.

Common mistakes

  • Extending the number of culture days to reach the density, moving closer to the cell age limit
  • Carrying conditions that worked in a small vessel straight into a large one, where growth slows because of differences in agitation and oxygen transfer
  • Transferring without watching the downward trend in viability, so that the cells are weakened at transfection

Check at your own site

  • Has your own cell state just before transfection been fixed within ranges decided from small-scale experiments?
  • What is the minimum working volume of your own production vessel in liters, and how many stages are needed ahead of it?

Step 5: Production platform selection

The choice of cell substrate × genome delivery method sets purification design, yield, COGS and regulatory explanation all at onceThe choice of cell substrate × genome delivery method sets purification design, yield, COGS and regulatory explanation all at once

Details and 3 alternatives

This step coversSelecting the AAV vector production platform, and culturing and expanding suspension HEK293 cells to build the foundation for upstream production (deciding the combination of cell substrate × genome delivery method and balancing scale, yield, quality and regulatory risk) (production platform selection, upstream production)

A step that decides the foundation of how AAV is made. It selects the combination of cell substrate and genome delivery method, and cultures and expands suspension HEK293 in serum-free medium to build the basis for production.

The choice here sets the downstream steps all at once. It is linked from purification design (the ratio of empty to full capsids, the host-derived impurity profile) to the burden on later steps.

It also spills over into yield, COGS (manufacturing cost) and regulatory handling. It can be called the first and biggest fork in the road for upstream.

Which production platform to use is the first big fork in the road for upstream, because the choice made here decides the downstream steps all at once. Specifically, purification design (the ratio of empty to full capsids, the host-derived impurity profile), yield and COGS (cost of goods), and the explanation to regulators (how to control manufacturing-derived impurities and the transfection reagent) are all dragged along by this one move. The most widely used approach in both clinical and commercial settings is the following. First, suspension-adapted HEK293 cells are expanded from N-1 to N in single-use stirred-tank bioreactors (STR). Then 3 types of plasmids are transiently transfected to produce AAV. This approach has clear advantages over adherent systems. Combining serum-free suspension culture with transient expression using PEI-based reagents is independent of scale, easy to scale up, closed and GMP-compatible. That is exactly why the single-use STR is now the standard format. In practice, this approach, with its clinical and commercial track record, is placed first as the reference method. Alternatives are then considered according to yield, cost and the scale required.

MakersCytiva, Sartorius, Pall, Thermo Fisher, Polyplus

Why it is the standard. (1) Flexibility and development speed. Any AAV serotype can be manufactured simply by swapping the transgene and rep/cap plasmids, so development can be run quickly. (2) Abundant regulatory precedent. Because the cells are mammalian, the post-translational modifications of the capsid are close to the human type, and with approved products such as Luxturna and Zolgensma there is a lot of precedent that can be shown to regulators. (3) Established manufacturing process. The combination of serum-free suspension culture and single-use STR is established for both GMP implementation and scale-up. PEI complexes can be added as they are, without a medium exchange (Sigma-Aldrich / Polyplus technical documents, Bioprocess Online: Xcellerex). On the other hand, there are also weaknesses. The yield per cell is about 10 times lower than in the Sf9 system, the amount of host DNA is large, and the proportion of empty capsids also tends to be higher. In addition, the 3 GMP-grade plasmids and the transfection reagent push up cost (COGS).

Check also. Suspension HEK293 + transient triple transfection is the representative method for early development through clinical supply. For large-scale commercial production, Sf9/baculovirus, stable producers and producer cell lines are also strong candidates, so it is not the one absolute standard.

Alternatives in practice

  • Sf9/baculovirus system · Sf9 insect cells + Sartorius/Cytiva SUB, Thermo Gibco Sf-900 III medium — Suited to high titer and large scale. Post-translational modifications and titer ratios differ from HEK293
  • Inducible / stable producer cell lines · HEK293-based inducible systems (e.g., Cevec / stable lines of various CDMOs) + SUB — No plasmids needed, advantageous in cost and scale. Line construction takes time
  • Fixed-bed bioreactor · Univercells scale-X / Pall iCELLis nano/500 (structured fixed bed) — Adherent culture with a high surface area. Where volumetric productivity is higher than in suspension systems

Step guide

What you actually do

  1. Derive the total vector genome quantity needed from the number of patients and the dose, and set the production target
  2. List the candidates, such as triple transfection of suspension HEK293, insect cells and stable producer cell lines
  3. Compare the candidates against each other for titer, the proportion of empty capsids and impurities, using the same analytical methods in small parallel cultures and the like
  4. For the chosen approach, set a plan for scaling up serum-free suspension culture and a procurement plan for plasmids, reagents and media

Decision points

Transient transfection, or a stable producer cell line?
While the item is still changing in early development, and at the stage of making many different items in small quantities, transient production, which starts up immediately, is suitable. For commercial manufacture of a single item in large quantities, a stable producer cell line is considered, since it removes the need to procure plasmids for every batch, but constructing the cell line takes several months and has to be redone for each item.
A stirred-tank vessel in suspension, or adherent culture (fixed bed and the like)?
A stirred-tank vessel in suspension extends scale by raising the volume and lets you carry over the equipment and operations of antibody manufacture. A fixed bed extends scale by adding culture surface area and makes it easier to carry over the conditions from a small unit. The places where conditions change with scale differ between the two, so measure and compare the actual yield per unit volume or per unit area.
Is the cell substrate HEK293 or insect cells (Sf9)?
The insect cell system is said to give high yields at large scale, but its post-translational modifications and proportion of empty capsids differ from HEK293. Mammalian cells have modifications closer to human ones and more precedent among approved products. How well they suit the serotype and the transgene is confirmed by measurement.
From which order of magnitude is the target scale estimated?
The culture scale needed, and the number of people who can be supplied at the yield achieved, are decided from the orders of magnitude of the single dose and the production per culture. As an example, an existing article cites reported values of 1.1×10¹⁵ vg for a single dose to a 10 kg child and around 1×10¹⁴ vg/L for production in suspension HEK293, and notes that even a 200 L culture leaves only a few patients' worth in hand. Doses vary greatly with the item and the route of administration, so calculate with your own values.

Common mistakes

  • Deciding the vessel size first and only then noticing that the total quantity needed is not met
  • Comparing catalog surface areas and volumes without converting them into actual yields, and deciding which is better on that basis
  • Not taking the product characteristic comparison data (bridging) needed in case the production system changes until just before the change

Check at your own site

  • Has your own total requirement been worked back from dose and patient numbers and set against the expected production and yield?
  • From when do you plan to take comparability data, in case your own production approach changes in the future?

Step 6: Transfection reference method

The central step in which PEI delivery efficiency of the 3 plasmids and complex design govern yield and the empty/full ratioThe central step in which PEI delivery efficiency of the 3 plasmids and complex design govern yield and the empty/full ratio

Standard methodSuspension HEK293Suspension HEK293
Details and 4 alternatives

This step coversDefining the reference transfection method for transient AAV production (intracellular delivery of the 3 plasmids) (transfection reference method)

A step that standardizes "how genes are put in" for transient AAV production. Plasmids with the information divided into 3 are introduced simultaneously into suspension HEK293.

The breakdown is 3 types: pITR, which carries the transgene flanked by ITRs, pRepCap, which supplies Rep and Cap, and pHelper, which supports production. These are brought together and added at once.

The 4 points to satisfy are efficiency, reproducibility, scalability and GMP compatibility. Delivery conditions that achieve all of them are fixed as the reference method, ensuring that the subsequent vector production is established.

When AAV is produced transiently, the required information is divided among 3 plasmids and put simultaneously into suspension-cultured HEK293 cells. The 1st is pITR (cis), which carries the transgene flanked by ITRs. The 2nd is pRepCap (trans), which supplies Rep and Cap. The 3rd is pHelper, which supplies the adenovirus-derived helper genes. Whether this delivery goes well shows up in 4 points: efficiency, reproducibility, ease of scale-up and GMP compatibility, and it directly governs vector yield and the ratio of particles with contents to empty particles (empty/full ratio). Deciding which transfection reagent to use and how to form the complex is therefore the center of this step. In clinical and commercial manufacturing, the method that uses PEI, a cationic polymer, to form precipitated complexes and bring the DNA into cells without relying on lipids has become established as the reference method, because it is inexpensive, can be used at any scale, and GMP-grade raw materials are readily available.

MakersCytiva, Sartorius, Sigma-Aldrich, Polysciences, Polyplus

Why it is the standard. PEIpro (Polyplus's GMP grade became available in 2018) is widely adopted in clinical AAV manufacturing as a PEI reagent that can be used from the development stage through commercial scale, and has become one of the de facto reference reagents. A plasmid weight ratio of 1:1:1 is the most widely used starting point in both the literature and practice, and PubMed 38479987 also states "widely used 1:1:1" as the baseline. A PEI-to-DNA ratio of roughly 2:1 (w/w) is reported in multiple studies as a representative value. PEIpro-GMP meets the requirements for cGMP viral vector manufacturing and comes with regulatory documentation, so it is positioned as the reference when moving into the clinic.

Check also. Treating PEI-based reagents such as PEIpro as the reference reagent is a reasonable organization. Note that the titer improvements reported for FectoVIR-AAV and similar (several-fold to about 10-fold) are reports based on manufacturer materials and application data, not standard performance based on peer-reviewed papers.

Alternatives in practice

  • Large-scale transfection with FectoVIR-AAV · Polyplus FectoVIR-AAV / FectoVIR-AAV GMP + Sartorius Biostat STR — High complex stability, suited to large scale and high density. Higher productivity than PEIpro
  • PEI MAX triple transfection · Polysciences PEI MAX 40000 (HCl salt, PD/research use) — Low cost, for PD and screening. GMP documentation is more complete with the Polyplus products
  • Calcium phosphate coprecipitation · CaCl2/HEPES system (prepared in-house, Sigma-Aldrich reagents) — Classic, low cost. pH-sensitive, inferior in robustness and scalability
  • Ratio optimization by DoE · Sartorius Ambr 250 HT + MODDE/DoE software — Comprehensive optimization of plasmid ratio, PEI:DNA ratio and seeding density

Step guide

What you actually do

  1. Mix the 3 plasmids at the set ratio and total DNA concentration into a complexing solution such as a low-salt serum-free medium
  2. Add the PEI-based reagent, stir, and leave for the set time to let the complexes form
  3. Add the complexes to the production vessel holding cells at the set density and viability
  4. After delivery, culture the cells with temperature, pH and DO controlled, and take samples in the run-up to harvest

Decision points

How are the plasmid ratio, the PEI ratio and the total DNA quantity decided?
1:1:1 is used as a starting point, but the optimal ratio changes with the serotype. In the design-of-experiments study introduced in an existing article, the optima for AAV2 and AAV9 were far apart. The three are not independent, so vary them within the same experimental design and watch the proportion of empty capsids and cell viability at the same time as titer.
Which transfection reagent do you choose?
A reagent available in the same family from research grade through to clinical and commercial GMP grade reduces re-optimization when you move from development to manufacturing. There are also dedicated reagents made for AAV, whose cited features include complex stability and suitability for high density. Choose by looking at the documentation for the grade transition and the effort needed to assess the quality impact of a change.
At what scale and how is the complex preparation carried out?
If complexes grow too large they are not taken up by the cells, and if they are too small they are not stable. Formation depends on the mixing conditions, so for large vessels choose an approach that can reproduce the order and duration of mixing, such as in-line mixing with a static mixer or a mixer bag that can be stirred. Whether the conditions decided at small scale are reproduced in the vessel is confirmed separately.
Where do you set the cell density at transfection?
Most procedures are run below 2×10⁶ cells/mL. Raising the density is known to lower the efficiency per cell, so that the total quantity does not grow. There are also designs that deliver the plasmids at high density under perfusion; the choice is made by balancing this against medium consumption.

Common mistakes

  • Varying only the plasmid ratio and optimizing the PEI ratio and total DNA quantity separately, thereby missing the optimum
  • Assuming that complex conditions worked out in small shake cultures carry straight over to mixing in the vessel
  • Changing the reagent while watching titer alone, and only later noticing that the proportion of empty capsids and the impurities have got worse

Check at your own site

  • Were your own plasmid ratio, PEI ratio and total DNA quantity decided by varying them within a single experimental design?
  • How do you plan to assess the quality impact when your own reagent moves from research grade to clinical grade?

Step 7: Perfusion, process intensificationIntensified option

Intensified upstream that maintains high density through perfusion and cell retention and raises yield from the same volumeIntensified upstream that maintains high density through perfusion and cell retention and raises yield from the same volume

Details and 3 alternatives

This step coversProduction intensification by perfusion (process intensification) and high-cell-density production (perfusion, process intensification)

A "tightening" step that raises the ceiling of production. In batch / fed-batch, cell density plateaus at around several million cells per 1 mL of medium.

What is spreading to address this is perfusion operation. While the stirred tank runs, a cell retention device keeps the cells in the vessel and medium is exchanged continuously to maintain a high density.

The advantage is that more AAV can be taken from the same volume. As process intensification, it is an upstream enhancement measure that lifts productivity.

In batch / fed-batch culture, cell density plateaus at around several million cells per 1 mL of medium (up to several ×10^6 cells/mL). To make more from the same volume, high-cell-density (HCD) culture by perfusion is spreading. Medium is exchanged continuously while a cell retention device keeps the cells in the culture vessel. Being able to continue culture while maintaining a high density in this way is becoming the reference approach for today's "intensified upstream." This method can keep the cell density as high as 9 to 50 million cells per mL (9×10^6 to 50×10^6 cells/mL). Moreover, both the continuous harvest of secreted AAV and the harvest after lysing the cells can be handled by the same single device.

MakersCytiva, Sartorius, Repligen, Polyplus

Why it is the standard. In the comparison of cell retention devices, Frontiers in Bioeng. Biotechnol. (2022, 10.3389/fbioe.2022.1020174) evaluates ATF (XCell ATF) and TFDF (KrosFlo TFDF) side by side in a 2 L-scale Biostat D-DCU. In lysate clarification, TFDF showed an advantage with an AAV recovery of 97%. As for the performance reached by HCD perfusion, another report (PMC12149485) transfected at 50 million cells per 1 mL (50×10^6 cells/mL) in a stirred tank (STR) and maintained 30 million cells/mL (≥30×10^6 cells/mL) or more thereafter. It demonstrated that even under this condition, the rAAV9 yield per 1 cell was equivalent to that of the reference shake flask.

Check also. Perfusion / high-density (HCD) culture is an advanced process intensification technique, positioned not as a required standard for all AAV manufacturing but as an option for increasing volumetric productivity.

Alternatives in practice

  • ATF perfusion · Repligen XCell ATF System (single-use/stainless steel, diaphragm type) — Backflow reduces clogging and maintains high cell density. Gentle shear
  • Pseudo-perfusion (semi-perfusion) · Intermittent medium exchange by centrifugation (Thermo Sorvall) or depth filtration — Simple but less continuous. For small scale and PD
  • Continuous harvest TFDF · Repligen KrosFlo TFDF — Continuous recovery of secreted AAV. A 3-fold yield versus batch has been reported for AAV8 and others

Step guide

What you actually do

  1. Run the stirred tank in perfusion mode and circulate the culture fluid through the cell retention device (ATF or TFDF)
  2. Feed fresh medium and withdraw cell-free fluid, holding the viable cell density target and the perfusion rate
  3. Once the target density is reached, deliver the 3 plasmids and the reagent
  4. Decide whether to harvest secreted AAV continuously or to harvest the cells themselves after delivery, and match the operation of the retention device to that

Decision points

Go to perfusion, or stay with fed-batch?
Perfusion is considered when you want to make more from the same volume, or to raise productivity per day of equipment occupancy. However, medium consumption, operation of the retention device and the per-cell efficiency at delivery all change, and there are more items to control than in fed-batch. Decide by setting estimates for both side by side, based on scale and target quantity.
Is the cell retention device an ATF or a TFDF?
ATF holds high density by suppressing fouling with alternating flow. TFDF combines tangential flow and depth filtration in one unit and can also be used for continuous harvest of secreted AAV. The retention mechanism, the recovery and the way fouling appears all differ, so make a small-scale comparison with your own vector and cells.
How is the perfusion rate decided?
It is decided using the cell-specific perfusion rate (CSPR) as a guide, while watching medium consumption and the state of the cells. Too fast and the medium volume and cost rise; too slow and nutrients are depleted or metabolites accumulate. Vary it at small scale to decide.
Where do you set the cell density at delivery?
Existing reports include cases where production per cell was maintained even when delivery was carried out at a high density on the order of 50 million cells/mL. However, consumption of medium, plasmids and reagent also rises, so confirm in your own system that the yield per cell does not fall.

Common mistakes

  • Not confirming at small scale the conditions under which the retention membrane fouls, so the run stops partway through
  • Taking it for granted that yield per cell does not fall at high-density delivery, without confirming it in your own system
  • Not building the extra medium required by perfusion into the procurement plan, so supply cannot keep up

Check at your own site

  • For your own perfusion, has the upper density at which yield per cell does not fall been decided by measurement?
  • Has it been confirmed with real fluid up to which day of operation your own retention device can be used without fouling?

Purification(6 steps)

Step 8: Harvest, cell lysis

A rate-limiting step that determines recovery by releasing intracellularly accumulated AAV through surfactant lysisA rate-limiting step that determines recovery by releasing intracellularly accumulated AAV through surfactant lysis

Details and 3 alternatives

This step coversRecovery and lysis of AAV from cells (lysate preparation / secretion harvest) (harvest, cell lysis)

The first downstream step that "takes out" the finished AAV from the cells. In triple transfection, most of the virus made does not leave the cells and accumulates inside.

So the cell membrane is chemically dissolved with a nonionic surfactant, and the vector is released all at once as a lysate (lysis solution). It is the exit after the end of culture.

How well this lysis goes governs the later steps. Conditions change the load on clarification and capture, so the design looks at both recovery and the ease of passing the next step.

When rAAV is made by introducing 3 plasmids simultaneously into HEK293 cells (triple transfection), most of the virus produced does not leave the cells but accumulates inside. So after culture ends, the cells must first be broken to release the vector. This lysis is the prerequisite for the clarification and capture that follow. Moreover, depending on how lysis is done, the load on the subsequent nuclease treatment and depth filtration changes, and the final AAV recovery goes up or down. In other words, this step is the rate-limiting point (the bottleneck in throughput) that determines how well the whole process turns out. For that reason, chemical lysis of cells with a surfactant has been chosen as the reference on the shop floor.

MakersCytiva, Merck, Sartorius, Pall, Repligen

Why it is the standard. Multiple manufacturer technical documents and patents state that "lysis is typically performed using a surfactant such as Triton X-100 or Tween 20," and lysis with surfactants such as Triton X-100 and Tween 20 has become the de facto reference method. In addition, a method that combines lysis under high-salt conditions with a salt-tolerant nuclease has been reported to digest DNA completely at 500 mM NaCl while increasing AAV titer by about 29% and improving infectivity. Merck recommends this as a commercialized process.

Alternatives in practice

  • Secreted harvest (lysis-free) · Direct supernatant recovery by TFF/depth filtration (Repligen/Merck) — For supernatant-secreted capsids (AAV9, etc.). The intracellular fraction is not recovered
  • Mechanical lysis · Microfluidics Microfluidizer / high-pressure homogenizer (with freeze-thaw) — Surfactant-free. Watch for capsid damage from shear
  • High-salt lysis · High-NaCl (~0.5 M) lysis buffer (prepared in-house) — Promotes dissociation of nucleic acids and host proteins. Consistent with the salt-tolerant nuclease downstream

Step guide

What you actually do

  1. Add the set volume of a lysis solution containing detergent to the production vessel or to the harvested bag
  2. Stir and dissolve the cell membranes for the set time and at the set temperature, releasing the vector into the fluid
  3. Where lysis is carried out under high-salt conditions, confirm the salt concentration and conductivity before sending the material on
  4. Receive the lysate in a hold bag and send it to the nuclease treatment step

Decision points

Lyse the cells to recover the vector, or recover the secreted fraction from the supernatant?
For serotypes such as AAV2, where most of the vector stays inside the cells, lysis is a given. For serotypes that readily appear in the culture supernatant, such as AAV8 and AAV9, a design that handles the supernatant as it is also works. In both cases, measure the distribution inside and outside the cells in your own system to decide.
Which detergent do you use, and under what conditions?
Lysis with a non-ionic detergent is often cited in the literature and in maker documents. Triton X-100 is covered by the European REACH regulation and the move to alternatives is advancing. Choose with continuity of supply and documentation included, and vary the concentration, temperature and time to decide, watching recovery and the load on the following steps (viscosity, DNA quantity).
Detergent lysis, or mechanical lysis?
Mechanical lysis uses no detergent, but capsid damage from shear and the cleaning and containment of the equipment are issues. The choice comes down to whether you control residual detergent by removal and testing, or assess the effects of shear.
Combine high-salt lysis with a salt-tolerant nuclease?
There are reports of increased titer with a method that lyses under high-salt conditions to release the bound nucleic acids and then digests them with a salt-tolerant nuclease. More salt affects the conductivity for the next step, so judge this together with the effort of dilution or buffer exchange.

Common mistakes

  • Noticing only after lysis that the total volume after lysis exceeds the capacity of the hold bags and filters
  • Starting to consider a detergent alternative only after the regulation has moved, so that the assessment for the grade switch is not ready in time
  • The conductivity of the high-salt conditions falls outside the binding conditions of the next step

Check at your own site

  • Are your own lysis conditions decided by looking not only at recovery but also at the effect on DNA quantity and viscosity downstream?
  • Is your own detergent ready to be switched to a different grade, in terms of supply and regulation?

Step 9: Nuclease treatment, clarification

Nuclease cuts host DNA to lower viscosity, and 2-stage depth filtration removes the load before captureNuclease cuts host DNA to lower viscosity, and 2-stage depth filtration removes the load before capture

Details and 4 alternatives

This step coversNuclease treatment and clarification (removal of cell debris by depth filtration) (nuclease treatment, clarification)

A pretreatment step that "clarifies" the liquid scattered by lysis. Breaking cells releases a large amount of host genomic DNA, which clogs resin and filters through viscosity and aggregation.

First, endonuclease cuts that DNA into small pieces and lowers viscosity. Primary and secondary 2-stage depth filtration then removes cells, debris and colloids and makes the liquid clear.

The aim is to prevent clogging in the next step. Clarifying here lets the AAV be handed smoothly to the affinity capture that follows.

When cells are lysed, a large amount of host cell genomic DNA is released. This DNA raises the viscosity of the liquid and forms aggregates that clog filters and purification resin (chromatography resin). So the DNA is first cut into small pieces with an enzyme called a nuclease to lower viscosity. The material is then put through 2-stage depth filtration to remove cells, debris (cell fragments) and colloids. This series of pretreatment is an essential step before capture chromatography (AAVX affinity), which captures the target virus, and how well it is done governs recovery and ease of later processing.

MakersCytiva, Merck, Sartorius, Repligen, Alfa Laval

Why it is the standard. Benzonase is the most widely used endonuclease in biopharmaceutical and viral vector manufacturing, and is the industry reference reagent with an abundant regulatory submission track record. For the clarification configuration, Merck technical documents and multiple "Scalable purification method for AAV1/8/9" patents specify the series of Millistak+ DOHC → A1HC → 0.2 µm Opticap. Combining this 2-stage depth filtration with NFF (normal flow filtration) is positioned as the reference method because of its good recovery, low cost and ease of process development.

Alternatives in practice

  • High-salt digestion with a salt-tolerant endonuclease · c-LEcta Denarase (retains activity under high-salt conditions) — Consistent with the high-salt lysis process. More salt-tolerant than Benzonase
  • Clarification by chromatography · Sartorius Sartoclear / flow-through charged depth membranes — Design that simplifies or omits the nuclease step
  • TFDF clarification · Repligen KrosFlo TFDF — Integrates harvest and clarification. Reduces depth filtration load
  • Centrifugation + depth filtration · Continuous centrifugation (Alfa Laval/GEA) + Merck Millistak+ — Upstream removal when solids are high. For large scale

Step guide

What you actually do

  1. Add an endonuclease and the required metal ion (Mg²⁺) to the lysate and let it react at the set temperature and time
  2. Pass the material through primary and secondary depth filters in series to remove cells, debris and colloids
  3. Pass it through a finishing 0.2 µm filter to protect the capture column that follows
  4. Receive the clarified fluid in a hold bag and send it to the capture step

Decision points

How are the nuclease dose and the reaction conditions decided?
Vary the enzyme concentration, reaction time, temperature and Mg²⁺ concentration with real fluid and decide by watching the viscosity and the DNA fragment length. If an upstream step uses EDTA the enzyme will not work, so align the buffer composition as well. Specific activity can vary by lot, so confirm the digestion rate in your own process fluid.
Are there conditions under which the nuclease can be omitted or simplified?
If the viscosity of the fluid and downstream fouling are tolerable and the DNA quantity can be brought within specification by another step, there is room to consider simplification. However, removing this contribution to clearance affects the residual DNA specification, so judge after measuring the contribution of each step, in accordance with the quality unit and the approved plan.
What decides the grade and the configuration of the depth filters?
Combine a coarse grade and a fine grade in series and decide the split from the differential pressure and turbidity trends when real lysate is run. AAV is small, about 26 nm in diameter, and by design is expected to pass through, but confirm from recovery that there is no adsorption to the filter medium. Charged types can reduce impurities but may adsorb the vector.
Place a TFDF or centrifugation upstream to reduce the load on depth filtration?
When solids are high, or for harvest fluid from high-density perfusion, an approach that removes cells upstream is considered. Combining TFDF, which integrates harvest and clarification, or continuous centrifugation is a trade-off between more equipment and recovery.

Common mistakes

  • The reaction fluid contains an inhibitor such as EDTA, so the nuclease does not work and the viscosity does not come down
  • Fixing the depth filter area from a lot in good condition, so that a poor lot fouls
  • The vector adsorbs to a charged filter medium and recovery falls

Check at your own site

  • Is your own depth filter area decided from the capacity measured with the worst-condition lysate?
  • Does your own nuclease have a procedure for re-confirming specific activity and the residual measurement when the supply source is changed?

Step 10: Capture purification◇ Branches

Affinity capture concentrates trace capsids to over 90% purity and lowers the load on downstream AEX and TFFWith engineered capsids, AAVX binding is not guaranteed, and the choice of capture method decides success

Standard methodCamelid single-domain antibody fragmentDetails →Affinity capture (AAVX): binding verification is a prerequisite for engineered capsids
With Engineered capsidAffinity capture (AAVX): binding verification is a prerequisite for engineered capsidsWith Natural serotypeCamelid single-domain antibody fragment
Details and 4 alternatives

This step coversPrimary capture of AAV vector: from the clarified production supernatant/lysate, most of the host cell proteins, DNA and medium components are removed in 1 step, and AAV capsids are highly selectively concentrated and purified (capture purification)

The starting point of purification, "fishing out" only the target AAV capsid from a sea of impurities. AAV in the production bulk is present in very small amounts, with large quantities of HCP, DNA and medium components mixed around it.

A camelid single-domain antibody fragment is used. It recognizes the three-dimensional structure and conserved loops of the capsid with pinpoint accuracy and selectively captures AAV in a single pass.

This single stage removes most of the HCP, DNA and medium components and concentrates to over 90% purity with high recovery. It is the capture step that hands a high-quality starting point to the polishing steps that follow.

In an AAV production bulk, the target AAV capsid is present in only very small amounts. Around it are mixed large quantities of host cell proteins (HCP) and DNA derived from HEK293 cells, Pluronic and medium components, and precursors of empty capsids. Affinity capture recognizes the three-dimensional structure (conformation) and conserved loops of the AAV capsid. A single pass therefore reaches a purity above 90%, and recovery is kept high (in many cases above 70–80%). As a result, the load on the downstream anion exchange that separates empty from full capsids and on the TFF that handles concentration falls greatly. Because of this effectiveness, affinity capture has become established as the reference method for primary capture in clinical AAV processes.

MakersCytiva, Sartorius, Thermo Fisher

Why it is the standard. POROS CaptureSelect AAVX shows binding reactivity to AAV1 through AAV8, AAVrh10, and even synthetic serotypes. With binding efficiency above 80% for each serotype, it has such broad selectivity that a serotype-independent, "platformable" capture can be set up. This is because the ligand mainly recognizes the peptide backbone of the DE/HI loops, whose structure is conserved in the AAV capsid, and has high cross-reactivity. In AAV processes from clinical to commercial, it is positioned as the de facto standard (industry reference) resin for the capture step, and Thermo Fisher provides technical and regulatory support. Sources: Thermo Fisher product page/brochure, Mol Ther Methods Clin Dev "High-efficiency purification of divergent AAV serotypes using AAVX affinity chromatography" (PMC9823220)

With Engineered capsid. POROS CaptureSelect AAVX recognizes the peptide backbone of the conserved DE/HI loops, so binding may drop or disappear with engineered capsids such as peptide insertions, chimeras, directed evolution and Anc types. Before introduction, dynamic binding capacity and recovery are measured for each capsid, and if binding is insufficient, switch to anion-exchange (AEX) capture, affinity with a different ligand, or a custom/immunoaffinity resin directed against the modification in question.

Alternatives in practice

  • AVB Sepharose-type VHH capture · Cytiva AVB Sepharose High Performance + ÄKTA process — The long-standing VHH resin that predates AAVX. Serotype coverage is more limited than AAVX
  • Serotype-specific VHH / synthetic ligand resins · Thermo POROS CaptureSelect AAV8/AAV9 affinity resins — High DBC/selectivity for a single serotype. Less versatile than AAVX
  • Non-affinity capture · Sartorius CIMmultus QA / Thermo POROS 50 HQ (AEX primary capture) — Avoids ligand dependence and low cost. Purity is inferior to affinity
  • Synthetic peptide ligand capture · Emerging synthetic peptide affinity resins (research/development stage) — Avoids animal-derived ligands. Track record and GMP documentation are limited

Step guide

What you actually do

  1. Condition the column with equilibration buffer and load the clarified fluid at the set flow rate to bind the AAV to the resin
  2. Wash away host cell protein, DNA and medium components with wash buffer
  3. Elute with a low-pH buffer and receive it immediately into a vessel containing neutralization buffer
  4. Carry out regeneration and cleaning (CIP) and record the number of cycles used and the pressure

What changes with the conditionWhether it is a natural serotype or an engineered capsid (peptide insertion, chimera, directed evolution and the like) (with natural serotypes, capture is readily built around a broad affinity resin that recognizes the conserved loops. With engineered capsids, binding may drop or disappear, so measure dynamic binding capacity and recovery before introduction. If it is insufficient, switch to capture by AEX, affinity with a different ligand, or custom affinity matched to the modification)

Decision points

Which affinity resin do you choose?
If you are developing several serotypes in parallel, a resin that binds a broad range of serotypes weighs more heavily. If you are repeatedly mass-producing a single serotype, resin lifetime under caustic cleaning counts. Catalog binding capacities are not aligned on serotype or units (vp/mL or gc/mL) and cannot be compared on order of magnitude alone, so choose on the binding efficiency and recovery measured with your own capsid.
How do you design the elution pH and the neutralization?
Because a strong acid is used to release the capsids, a long time spent at acidic pH leads to aggregation and loss of titer. Write the volume of neutralization buffer and the timing of its addition into the procedure; for serotypes that are hard to elute, maker documents give examples of using additives such as arginine. Decide by measuring recovery with your own capsid.
Affinity capture, or non-affinity capture such as AEX?
Where you want to avoid dependence on a ligand and hold down cost, AEX is considered, but its purity is said to be lower than affinity. For affinity resins, the limited origin and sources of supply of the ligand are also examined from the documentation and supply standpoint.
Can empty capsids be reduced in this step?
Affinity capture recognizes the capsid surface, so it does not distinguish empty from full and binds them alike. Design this step on the premise that empty/full separation is placed separately after it.

Common mistakes

  • Deciding on a resin by comparing catalog binding capacities without aligning serotype or units
  • Neutralization of the eluate is late, the time at acidic pH drags on, and the capsids aggregate
  • Carrying an affinity resin that worked for a natural serotype straight over to an engineered capsid

Check at your own site

  • Have the binding capacity and recovery for your own capsid been measured before introduction?
  • Do your own elution and neutralization have an upper limit on the time spent at acidic pH written into the procedure?

Step 11: Empty / full separation polishing step◇ Branches

A polishing step that uses the slight charge difference of the enclosed DNA with an AEX salt gradient to concentrate full capsids and remove emptiesSurface charge changes with the modification, so AEX elution conditions are re-optimized each time

ReagentsEquilibration/binding buffer (Bis-Tris / Tris)Elution salt (NaCl gradient)Poloxamer 188
With Engineered capsidSurface charge changes with the modification, so AEX elution conditions are re-optimized each timeWith Natural serotypeEmpty/full capsid separation by salt gradient elution in anion-exchange chromatography (AEX)
Details and 3 alternatives

This step coversEmpty/full capsid separation: a polishing step that concentrates full capsids containing the gene of interest and removes empty and partially filled capsids. The most important polishing step governing quality and titer in AAV manufacturing. (empty/full separation polishing step)

The most important polishing step determining quality, which sorts "filled" from "empty" capsids. Only full capsids are concentrated, and empty and partially filled capsids are removed.

The only difference between the two is the very slight negative charge difference produced by the enclosed DNA. So anion exchange (AEX) at pH 8.5–9 gives the surface a negative charge, and the salt concentration is raised little by little to tell them apart.

This high-resolution gradient elution is the crux, extracting a slight difference as a difference in potency and titer. It is the key point that governs dose design and safety of the product.

The difference between full and empty capsids is nothing more than the very slight difference in negative charge brought by the enclosed genomic DNA. Anion exchange (AEX) chromatography can use this charge difference directly for separation. Combined with high-resolution gradient elution in which the salt concentration is raised little by little, it distinguishes the two most straightforwardly, so it has become established as the reference method on the manufacturing floor. In the procedure, the capsid surface is first negatively charged at pH 8.5–9 and bound to a Q-type ligand, and the salt concentration is then gradually raised. The weakly charged empty capsids come off first, followed by elution of the target full capsids.

MakersSartorius BIA Separations, Cytiva, Sartorius, Thermo Fisher, Pall

Why it is the standard. Measured values have also been published. With a CIMmultus QA HR monolith, empty AAV2/8 capsids eluted within a narrow conductivity window of ±3%, and full capsids could be concentrated to 88±9% (with a genome recovery of 77±3% at that time). The salts used for elution have also been compared, and it is reported in BioProcess International and elsewhere that the divalent salt MgCl2 separates better than the monovalent NaCl. Reproducibility has further been confirmed with multiple serotypes such as AAV2/5/8, and AEX is widely accepted as the reference method for empty/full separation. There is, however, a caution. If capsids are left bound for a long time, the structure of empty capsids changes, retention times shift and resolution falls, so careful control of residence time in the column is essential.

Check also. AEX is the practical standard for scalable purification, but it is strongly serotype- and condition-dependent, and separation of partial capsids can be less clear than with AUC/MP/CDMS. The final reference confirmation of full/empty/partial is done by SV-AUC, MP and CDMS, which rely on a different principle.

With Engineered capsid. Amino acid modifications and peptide insertions on the capsid surface change the isoelectric point and charge distribution, so the elution gradient for natural serotypes cannot be carried over. The pH, salt species (NaCl/MgCl2) and gradient are re-optimized for each engineered capsid. The final empty/full determination is confirmed by a different method: SV-AUC, CDMS or mass photometry (charge-independent and less affected by the modification).

Alternatives in practice

  • AEX membrane flow-through · Sartorius Sartobind Q / Pall Mustang Q (membrane adsorbers) — High flow rate, low pressure. Removes impurities in flow-through; full/empty separation is inferior to monoliths
  • Two-stage (2-pass) AEX strategy · CIMmultus QA HR (2 passes under different conditions) — Concentrates high-purity full capsids stepwise. Trade-off with yield
  • Affinity-integrated full capsid enrichment · Optimizing pH/salt conditions in the affinity stage such as POROS AAVX — Moving the step earlier reduces the separation load. Shortens the process

Step 12: UF/DF, 0.2 µm filtration

UF/DF keeps AAV on the membrane and does concentration and formulation buffer exchange at the same time, then 0.2 µm filtration makes it a drug substanceUF/DF keeps AAV on the membrane and does concentration and formulation buffer exchange at the same time, then 0.2 µm filtration makes it a drug substance

Details and 4 alternatives

This step coversConcentration and buffer exchange (UF/DF): the purified AAV is concentrated to the target concentration and exchanged into the formulation buffer, and finally filtered through a sterilizing-grade membrane at 0.2 µm to give the drug substance / bulk (UF/DF, 0.2 µm filtration)

A step that "concentrates and changes the clothes of" purified AAV. AAV, about 25 nm in diameter, is concentrated to the target concentration and exchanged into the formulation buffer.

What is used is the sieving effect of the membrane. AAV is larger than the membrane pores and cannot pass through, so it stays on the membrane while only water and low-molecular-weight species escape. This is the principle of ultrafiltration (UF/DF).

Using this property, concentration and buffer exchange can proceed together. Finally the material is passed through sterilizing-grade filtration and finished as the drug substance / bulk.

A step that concentrates the purified AAV (about 25 nm in diameter) to the target concentration and then exchanges it into the formulation buffer. Ultrafiltration (UF/DF, tangential flow filtration) is used here, and because AAV is sufficiently larger than the membrane pores, it does not pass through the membrane. Water and low-molecular-weight species can therefore escape through the membrane while only AAV stays on the membrane. Exploiting this property allows concentration and buffer exchange (diafiltration) to proceed together, which is why this is the reference method. Finally, the material is filtered through a 0.2/0.22 µm sterilizing-grade filter to remove bioburden such as bacteria. What has been through this final filtration is taken as the drug substance / bulk, and this is a standard step in line with the sterile product requirements set by each country's pharmacopoeia.

MakersCytiva, Merck, Sartorius, Pall, Repligen

Why it is the standard. An MWCO (molecular weight cutoff) of 100 kDa is used. This is the standard value for AAV ultrafiltration with both hollow fibers and flat sheets, and papers and manufacturer documents alike adopt it. It is a value aimed at retaining AAV on the membrane while passing only low-molecular-weight impurities. The final sterile filtration is performed at 0.2/0.22 µm, which is common to the process descriptions of the various companies as the last step of DSP (downstream purification). Poloxamer 188 is added to counter aggregation, and it is a standard additive used as a surfactant that prevents aggregation in AAV formulations. Note that sterile filtration and bioburden control are based on the pharmacopoeias of each country and sterile product requirements.

Check also. MWCOs of 100 to 300 kDa are often considered, and 100 kDa is used as a representative starting condition (not a fixed value). The final sterile filtration is separated out as the next step (sterile filtration).

Alternatives in practice

  • Hollow fiber TFF · Repligen KrosFlo hollow fiber module (mPES, 100 kDa) — Gentle shear, open channel and low clogging. Dead volume slightly large
  • Flat-sheet cassette TFF · Cytiva ÄKTA flux + Hydrosart/Omega cassettes (Sartorius/Pall) — High area / small footprint. Shear is higher than hollow fiber
  • Single-pass TFF (SPTFF) · Repligen SPTFF / Pall Cadence in-line — In-line concentration links steps. Buffer exchange is needed separately
  • Choice of final sterilizing membrane · Pall Supor EKV (PES) / Merck Millipore Express SHC — Optimize capsid adsorption and yield through membrane material and pore size

Step guide

What you actually do

  1. Install the membrane (hollow fiber or flat-sheet cassette) in the TFF system, clean and equilibrate it, and confirm the water permeability
  2. Circulate the AEX pool and concentrate it at the set transmembrane pressure and flow rate
  3. Circulate at constant volume while adding formulation buffer (diafiltration), exchanging the set number of volumes
  4. Adjust to the target concentration, recover the material from the membrane surface and receive it into a bag

Decision points

Hollow fiber, flat-sheet cassette, or single-pass TFF?
Hollow fibers have an open flow path, foul less readily and apply gentler shear. Flat-sheet cassettes give a large area in a small footprint but apply higher shear. Single-pass TFF has no recirculation loop and is easier to connect between steps, but buffer exchange has to be done separately. For particles as large as AAV, compare resistance to fouling and hold-up (the volume left in the membrane and piping) with real fluid.
How do you choose the nominal molecular weight cut-off and the material of the membrane?
AAV is well larger than the membrane pores and does not pass through. Since only water and small molecules pass, the literature has many examples using a nominal cut-off of 100 kDa, and the materials used are regenerated cellulose and PES types. Confirm with real fluid whether protein adsorption is low and whether the membrane withstands cleaning.
When do you add the surfactant (poloxamer 188)?
One design includes it in the formulation buffer used for the exchange, to suppress adsorption and aggregation. The aim is to limit adsorption losses to membrane and piping surfaces, but the final concentration follows the formulation design. Also confirm that the concentration does not shift during concentration.
How do you decide operating conditions that limit shear and aggregation?
Vary the crossflow rate, the transmembrane pressure and the number of exchange volumes at small scale and decide by watching vector recovery and aggregation (by DLS and the like). Pushing the concentration factor too high can raise the local concentration and advance aggregation.

Common mistakes

  • Not allowing for hold-up in a small batch, so that recovery falls below expectation
  • Not adding surfactant without considering adsorption to membrane and piping, so that losses occur with dilute fluid
  • Pushing the concentration factor too high, creating locally high concentrations and advancing aggregation

Check at your own site

  • Is your own TFF membrane area decided from the flux and processing time measured with real fluid?
  • In your own smallest batch, how far does recovery fall once hold-up is subtracted?

Step 13: Final sterile filtration

Low-concentration AAV loses 30–40% of titer to membrane adsorption, so a low-adsorption membrane achieves both sterility and loss suppressionLow-concentration AAV loses 30–40% of titer to membrane adsorption, so a low-adsorption membrane achieves both sterility and loss suppression

Details and 3 alternatives

This step coversSterile filtration (0.2 µm sterilizing-grade filtration): minimizing membrane adsorption loss of AAV capsids while assuring sterility (final sterile filtration)

A step that passes the final formulation through a 0.22 µm sterilizing-grade membrane to assure sterility. It is the gate to making a product that can be administered.

However, AAV drug substance has a low active ingredient concentration (0.01–0.1 mg/mL), and capsid adsorption to membrane and tubing surfaces alone loses 30–40% of titer.

That is why a low-protein-binding membrane is chosen to sterilize reliably while holding down adsorption loss. Success depends on whether sterility and prevention of vector loss can both be achieved.

The concentration of active ingredient in AAV drug substance is very low (mostly 0.01–0.1 mg/mL). Consequently, even capsids simply adsorbing to the surfaces of filter membranes, tubing and containers have been reported to cause loss of 30–40% of titer. Sterile filtration in the final step is indispensable for ensuring sterility. However, how this loss is controlled decides success or failure, so how the reference filtration method is chosen is important.

MakersCytiva, Merck, Sartorius, Pall, Merck Millipore

Why it is the standard. Durapore PVDF, which is sterilizing grade and resists protein adsorption, is used as the standard membrane. Sigma's AAV final filling guide also recommends low-binding membranes (PVDF/PES). Filter loss of AAV differs by serotype, but recovery has been reported to be restored by adding polysorbate or poloxamer (J Pharm Sci 2025).

Alternatives in practice

  • 0.2 µm PES double-layer sterile filtration · Sartorius Sartopore 2 (0.45 + 0.2 µm PES double layer) — Built-in prefilter gives clogging resistance. Where throughput is higher than Durapore
  • Filter preconditioning / saturation filtration · Membrane saturation flush with poloxamer-containing buffer — Minimizes initial adsorption loss. Flush volume needs to be minimized
  • Closed aseptic processing without filtration · Sterile connectors (Cytiva ReadyMate / Pall Kleenpak) + manual dispensing — Avoids capsid loss from filtration. Bioburden control is strict

Step guide

What you actually do

  1. Wet (flush) the flow path with the filter installed and prepare for the integrity test
  2. Carry out the pre-use integrity test and confirm that it passes
  3. Pass the formulated product through at the set pressure or flow rate and collect it in a sterile receiving bag
  4. Carry out the integrity test after filtration, apply the method for recovering the fluid left in the filter and piping, and record the results

Decision points

Is the membrane material PVDF or PES?
Both low-protein-binding PVDF and a two-layer PES configuration are candidates, and a configuration with a built-in prefilter can be more resistant to fouling. Losses on filters differ by AAV serotype, and there are reports that recovery returns when poloxamer or polysorbate is added. Choose by measuring recovery with your own vector and formulation.
Pre-wet the membrane to reduce initial adsorption?
There is a design that wets the membrane in advance with a buffer containing poloxamer to reduce initial adsorption losses. A larger flush volume dilutes the product, so the design has to keep the volume used to a minimum.
How do you design the integrity test before and after use?
EU GMP Annex 1 sets out the thinking that a sterilizing filter be verified after sterilization and before use (PUPSIT) and that a non-destructive integrity test be carried out after use before it is removed from the housing. Where PUPSIT is not possible, the alternative is explained by risk assessment. Test piping and ports have to be built into the flow path. The test method and acceptance criteria follow the approved procedures and the quality unit.
Can filtration assure the safety of the viral vector itself?
Against a 0.2 µm pore size, AAV is about 26 nm in diameter, so AAV passes through. This step is not a virus removal step but a microbial removal step. Mycoplasma can pass 0.2 µm, so it is controlled by a separate test.

Common mistakes

  • Not allowing for initial adsorption, so that the titer of the first fraction falls sharply with dilute fluid
  • Not considering the volume of wetting fluid, so that the flush dilutes the product
  • Not building the piping and ports used for the integrity test into the flow path, so the pre-use test cannot be carried out

Check at your own site

  • Is your own sterile filtration choosing the membrane on the basis of recovery measured with real fluid?
  • Do your own integrity tests have the pre-use and post-use acceptance criteria, and the handling of a failure, written into the approved procedures?

Formulation and fill-finish(4 steps)

Step 14: Fill-finish, aseptic filling

Because the product is not complete unless the sterile-filtered formulation is actually aseptically filled into and closed in the final containerBecause the product is not complete unless the sterile-filtered formulation is actually aseptically filled into and closed in the final container

Standard methodSingle-use filling line in which peristaltic-pump aseptic filling and stoppering are done inside a single-use isolator and capping is done in a separate chamberSingle-use filling line in which peristaltic-pump aseptic filling and stoppering are done inside a single-use isolator and capping is done in a separate chamber
EquipmentCytiva Microcell Vial Filler (closed, glove-less aseptic filling isolator, peristaltic pump type, 2R–50R, 1.0–50 mL) or Cytiva SA25 Aseptic Filling Workcell (formerly Vanrx, under Cytiva since 2021, glove-less robotic filling isolator). Robotic aseptic filling machines from Optima Pharma are also used in some cases. Capping: single-use capper in a separate chamber.
ReagentsGamma-sterilized single-use filling tube / nozzle assemblies (Cytiva/Sartorius single-use flow paths), sterilized ISO glass vials (Schott/SGD), rubber stoppers (West Pharmaceutical FluroTec), aluminum caps (West/Datwyler).
Details and 3 alternatives

This step coversAseptic filling, stoppering and capping of the AAV drug product (fill-finish): the sterile-filtered final formulation is aseptically filled into vials in a Grade A environment, and the final container and closure system is completed by rubber stoppering and aluminum cap crimping (fill-finish, aseptic filling)

A step that fills the sterile-filtered formulation into containers and seals them, finishing it in a "form that can be administered." Aseptic operation takes place inside an isolator / RABS in a Grade A environment.

The product is aseptically filled into glass or resin vials by peristaltic pump, followed by rubber stoppering. Aluminum caps are crimped in a separate chamber to complete the container and closure system.

What it takes on is preventing cross-contamination and assuring sterility. Only after passing through here does the AAV injectable become a final product that can be administered.

An AAV injectable becomes a final product that can be administered only after 0.22 µm sterile filtration, filling into glass/resin vials in a sterile environment, and closure with rubber stoppers and aluminum caps. Aseptic operation inside an isolator / RABS is a standard step essential for preventing cross-contamination and assuring sterility.

MakersCytiva, Sartorius, Syntegon, Bausch+Ströbel, IMA

Why it is the standard. Cytiva Microcell can minimize product loss and cross-contamination of low-fill-volume, high-value viral vectors with a single-use flow path, and Syntegon's robot/isolator filling is adopted as the working standard in small-batch, high-mix cell and gene therapy fill-finish.

Alternatives in practice

  • RABS filling · Filling line with a restricted access barrier system (Bosch/Syntegon, Optima) — More flexible equipment than an isolator. Decontamination level is inferior to an isolator
  • Prefilled syringe filling · Bausch+Ströbel / Optima PFS filling lines — Improves ease of administration. Watch for AAV adsorption and silicone oil compatibility
  • Single-use filling assembly · Cytiva/Sartorius single-use filling flow paths — No cleaning validation needed, reduces cross-contamination. Flexible for small batches

Step guide

What you actually do

  1. Bring the sterilized filling flow path (tubing and nozzles), vials and rubber stoppers into the isolator or RABS
  2. Meter the set volume with a peristaltic pump or similar and fill it into the vials
  3. Insert the rubber stoppers immediately after filling and crimp the aluminum caps in a separate chamber
  4. Record the results of fill volume verification (by weight), environmental monitoring, visual inspection and container closure integrity testing

Equipment and materials

EquipmentAseptic filling machineIsolator or RABSEnvironmental monitoringContainer closure integrity (CCI) tester
Materials and reagentsSingle-use flow path for filling (tubing, nozzles)VialsRubber stoppersAluminum caps

Decision points

An isolator, or a RABS?
An isolator is decontaminated and closed. A RABS gives more flexibility in the equipment but is said to reach a lower level of decontamination than an isolator. For viral vectors, with small batches and many items, there are examples of adopting gloveless robotic isolators or configurations using disposable flow paths.
Which metering method do you use for filling?
There are three: peristaltic, rotary piston and time-pressure. For low-volume, low-concentration AAV, the peristaltic type can be suitable, since it has no sliding surfaces against metal parts and the product-contact parts can be disposable. For high-viscosity formulations and large volumes, a rotary piston can be better for reproducibility. Shear and adsorption in the product-contact parts are confirmed from the titer of real fluid.
How do you choose the container and stopper combination?
Adsorption, leachables and sealing at low temperature change with glass versus polymer and with whether the stopper is coated. If the product is stored frozen, look at sealing at low temperature as well. Evaluate container closure integrity for the combination, not for container and stopper separately.
How do you design the fill volume verification (IPC)?
Weight verification of every unit (100% IPC) is an indicator of weight reproducibility. It does not assure anything about capsid adsorption or aggregation, so confirm the titer after filling separately by a functional assay.

Common mistakes

  • Mistaking an indicator of the filling machine's weight accuracy for assurance about adsorption or titer
  • Evaluating container and stopper separately and not looking at the seal for the combination
  • Not allowing for the line hold-up volume, so that too few units can be filled in a small batch

Check at your own site

  • Does your own filling choose the method after confirming shear and adsorption in the product-contact parts from the titer of real fluid?
  • Is your own container and stopper combination evaluated for container closure integrity at the storage temperature?

Step 15: Formulation, formulation design

A formulation with poloxamer 188, high ionic strength and sugar that suppresses 90% loss from container adsorption and serotype-dependent aggregationA formulation with poloxamer 188, high ionic strength and sugar that suppresses 90% loss from container adsorption and serotype-dependent aggregation

Details and 4 alternatives

This step coversSuppressing aggregation / surface adsorption and securing long-term stability through formulation design of the AAV drug substance (buffer system, salt, surfactant, sugar, osmolality, pH) (formulation, formulation design)

A design step that prevents AAV from "sticking to the wall and disappearing" through formulation. At low concentrations, up to 90% is lost by adsorption to container walls, tubing and filter surfaces, and titer also varies.

The countermeasure is to assemble the formulation. A combination of buffer system, salt, nonionic surfactant poloxamer 188, sugar, osmolality and pH suppresses both adsorption and aggregation.

The aim is to secure long-term stability. Depending on the serotype, particles aggregate with one another, so a formulation that suppresses loss and aggregation is built with reference to the design guidelines of approved products.

AAV capsids show a troublesome property at low concentrations. They adsorb to the walls of containers, to tubing and to filter surfaces, so that up to 90% of vector particles are lost and genome titer also varies. Depending on the serotype, particles also aggregate with one another. How to suppress such loss and aggregation is the crux of formulation design. Approved AAV products show the answer. Zolgensma contains 200 mM NaCl, 1 mM MgCl2 and 0.005% poloxamer 188 in 20 mM Tris (pH 8.0), and Luxturna contains 180 mM NaCl and 0.001% poloxamer 188 in 10 mM phosphate (pH 7.3). Both add the nonionic surfactant poloxamer 188 as standard, and combine high ionic strength (equivalent to 200 mM or higher) with sugars that protect the capsid to suppress aggregation and adsorption. This is the reference method in practice.

MakersCytiva, Merck, Repligen, Advanced Instruments, Malvern Panalytical

Why it is the standard. The package insert compositions of the FDA-approved Zolgensma (20 mM Tris pH 8.0 / 200 mM NaCl / 1 mM MgCl2 / 0.005% poloxamer 188) and Luxturna (10 mM phosphate / 180 mM NaCl / 0.001% poloxamer 188, pH 7.3) demonstrate that the combination of poloxamer 188 and high-ionic-strength buffer is the reference method for suppressing aggregation and adsorption. Losses of up to 90% have been reported for AAV adsorption, and surfactant and low-adsorption wetted materials are the key points.

Alternatives in practice

  • Changing the surfactant to PS80/PS20 · Polysorbate 80/20 (Merck / Croda Super Refined) formulation screening — Adsorption suppression and oxidative stability differ from poloxamer. Optimize for each product
  • Stabilization based mainly on sugars/polyols · Sucrose/trehalose/sorbitol formulation (Pfanstiehl low-endotoxin grade) — Freeze and freeze-drying protection. Reduces dependence on surfactant
  • Optimization of pH and ionic strength · DoE formulation screening + DLS/SEC-MALS evaluation — Aggregation control through buffer system optimization. Minimizes the amount of surfactant
  • Freeze-dried formulation · Freeze dryer (SP Scientific LyoStar / Millrock) + bulking agent (mannitol) — Enables ambient/refrigerated distribution. Formulation design tolerant of freeze-drying stress is needed

Step guide

What you actually do

  1. Prepare formulations at small scale that combine candidate buffers, salt concentrations, pH values, surfactants and sugars
  2. Exchange the AAV into the buffer of each formulation by TFF or similar and align the concentrations
  3. Measure pH, osmolality, particle size (DLS), aggregation and titer (genome and infectious)
  4. Compare how well adsorption and aggregation are suppressed in freeze-thaw and storage studies, and narrow down the formulation

Equipment and materials

Decision points

Is the surfactant poloxamer 188 or polysorbate?
Dilute AAV is readily lost to adsorption on containers and filter membranes, and a surfactant suppresses this by occupying the interface first. Poloxamer has no ester bonds, resists hydrolysis, and is used in approved AAV products. Polysorbate has a deeper track record, but its degradation products can act as nuclei for subvisible particles. Decide the type and concentration with your own product, matched to the stresses expected.
How do you decide the salt concentration and the buffer system?
Approved products combine a buffer system with a relatively high ionic strength. As examples, Zolgensma is 20 mM Tris (pH 8.0) with 200 mM NaCl, 1 mM MgCl₂ and 0.005% poloxamer 188, and Luxturna is 10 mM phosphate (pH 7.3) with 180 mM NaCl and 0.001% poloxamer 188. The optimum changes with serotype, concentration and whether the product is frozen, so keep other companies' formulations as a starting point only and vary them by design of experiments.
Frozen, refrigerated or lyophilized?
The storage form is decided by batch size and shipping conditions. Freezing halts chemical degradation but brings the stresses of ice crystals and freeze concentration. Refrigeration makes distribution easier but gives weaker long-term stability. Lyophilization makes refrigerated or ambient distribution possible but requires a formulation designed to withstand drying stress and validation of the process.
How much sugar (sucrose, trehalose) do you include?
Sugars are used to protect against freezing and lyophilization, and there are designs that use them to reduce reliance on surfactant. Check with an osmometer that the osmolality does not become too high and stays acceptable for an injectable. Choose a low-endotoxin injectable grade.

Common mistakes

  • Carrying a culture-grade poloxamer over into the formulation without support for its use in an injectable
  • Taking another company's approved formulation as the answer as it stands, even though the serotype and concentration differ
  • Deciding the filling equipment before the formulation, and having to reassess the suitability of product-contact materials every time the formulation changes

Check at your own site

  • Is your own formulation decided by measuring, container by container, whether adsorption or aggregation is the main loss?
  • Is your own surfactant of a grade with documentation supporting injectable use, and is control of its degradation products also in the plan?

Step 16: Frozen storage of drug substance

Storage at −60 °C or below with surfactant, sugar and low-adsorption containers prevents capsid rupture from freezing stressStorage at −60 °C or below with surfactant, sugar and low-adsorption containers prevents capsid rupture from freezing stress

Details and 3 alternatives

This step coversLong-term frozen storage of AAV drug substance / drug product (low-temperature freezers, containers, freeze-thaw stability) (frozen storage of drug substance)

A step that freezes and keeps AAV drug substance / drug product in an ultra-low-temperature freezer at −60 to −80 °C. It lets the product sleep stably for a long time at deep cold.

Capsids (the shell of the virus particle) are fragile and tear, aggregate or adsorb under mechanical stress from the ice-water boundary, the air-liquid boundary and solute recrystallization during freezing.

That is why it is kept deeply cooled together with a formulation containing surfactant and sugar. The aim is to maintain a stable state that can withstand freezing and thawing.

The AAV capsid (the shell of the virus particle) breaks easily when it touches the boundary between ice and water or the boundary between air and liquid. When components dissolved at freezing recrystallize, force is applied there as well. Under such mechanical stress the capsid can tear, clump together, or stick to container surfaces so that it can no longer be recovered. The conditions that prevent this are almost fixed: cooling deeply and keeping it at minus 60 °C or lower, combined with surfactant, sugar and containers to which the contents adhere poorly. This is established as the reference for long-term stability with activity retained, and the commercial AAV products Luxturna and Zolgensma adopt the same design.

MakersEppendorf, PHCbi, ELPRO, Pfanstiehl, SP Scientific

Why it is the standard. The reference is the marketed AAV products Luxturna (FDA package insert: contains 0.001% poloxamer 188, stored at ≤−60 °C) and Zolgensma (shipped frozen at ≤−60 °C). In the literature (J Pharm Sci 2022, Wright et al.'s study of the freeze-thaw rupture mechanism), adding poloxamer 188 at ≥0.0005% w/v is reported to eliminate the recovery loss of up to about 60% that occurs without it, and to keep capsid rupture to ≤1% per cycle. Adding sucrose suppresses ssDNA leakage during freeze-thaw in the DPBS system, and histidine is suited to freezing, with pH variation of <1 unit between +25 and −30 °C. With COP vials and fluoropolymer-coated stoppers, no adsorption loss is reported.

Alternatives in practice

  • LN2 vapor-phase cryopreservation · Chart MVE 1500 series vapor-phase LN2 tanks (−150 °C or below) — Best long-term stability (below the glass transition point). High equipment and LN2 supply cost
  • Storage as a freeze-dried solid · SP Scientific LyoStar / Millrock freeze dryers — Refrigerated/ambient distribution possible. Freeze-drying process validation is needed
  • Short-term refrigerated storage at 2–8 °C · GMP pharmaceutical refrigerators (Thermo Scientific/Helmer) — Only within the expiry period after thawing. Long-term stability is inferior to frozen storage

Step guide

What you actually do

  1. Fill the containers (vials or bags) with the set volume of formulated solution and record the label, lot number and position
  2. Arrange them on the set shelf and position of the ultra-low temperature freezer, taking the temperature distribution inside the chamber into account
  3. Record the chamber temperature continuously and set and verify the alarms
  4. When material is used, control the thawing method and the number of thaws and take out only the amount needed

Decision points

A mechanical ultra-low temperature freezer, the liquid nitrogen vapor phase, or lyophilization?
Many AAV products are stored in mechanical freezers at minus 60 to 80 °C, and some approved products specify frozen storage and shipping. The liquid nitrogen vapor phase, below the glass transition point, is said to be favorable for long-term stability, but the equipment and the liquid nitrogen supply are costly. Lyophilization makes refrigerated or ambient distribution possible but requires validation of the drying.
How do you control the number of freeze-thaw cycles and the cooling and thawing rates?
Capsids are readily damaged at the ice-water interface, at the air-liquid interface and by recrystallization of solutes on freezing, and mechanistic studies have shown that repeated thawing increases rupture. Decide the surfactant concentration and the sugar composition from small-scale freeze-thaw studies, and write the thawing method at point of use and the permitted number of cycles into the procedure.
What do you use for the container?
Adsorption to the container wall leads to large losses with dilute fluid. There is a report that no adsorption was observed with the combination of COP vials and fluoropolymer-coated stoppers, and polypropylene and siliconized glass are also candidates. Compare adsorption with your own fluid and also look at the sealing of the stopper at low temperature.
How do you handle the freezer's temperature distribution and the provisions against power failure and breakdown?
Minus 80 °C is a set point, and the temperature differs with position in the chamber. Near the door and the top shelf are the worst locations; take temperature mapping both empty and fully loaded and decide the range in which material may be stored. Which of power supply, a backup unit and distributed storage you choose is decided by the loss if the material is lost.

Common mistakes

  • Not taking temperature mapping of the chamber, and placing an important lot in a poor location
  • Operating with an arrangement in which nobody comes even when the alarm sounds
  • Not controlling the number of freeze-thaw cycles and refreezing what is left after thawing

Check at your own site

  • Are your own storage temperature excursion criteria decided from the stability data of the contents?
  • For your own freezer alarms, who responds within how many minutes at night and at weekends?

Step 17: Cold chain transport

Maintain −60 °C or below from shipment to administration to prevent capsid rupture, aggregation and titer loss from freeze-thawMaintain −60 °C or below from shipment to administration to prevent capsid rupture, aggregation and titer loss from freeze-thaw

EquipmentValidated shipping container (insulated passive shipper)Temperature data loggerLN2 vapor-phase shipper
ReagentsDry iceLiquid nitrogen
Details and 2 alternatives

This step coversTransport and cold chain for AAV drug product (shipping while maintaining deep-cold temperature) (cold chain transport)

A step that carries frozen AAV "still cold" from shipment to administration. Maintaining temperature is itself the quality assurance.

If temperature control breaks down or freezing and thawing are repeated, AAV capsids rupture and aggregate and titer falls. That is why temperature must be assured over the entire route.

The means are dry ice (about −78.5 °C) packing or cryoshippers. −60 °C or below is maintained over the entire process as a validated cold chain, and the product is delivered frozen.

AAV is fragile if temperature control breaks down during transport. If it departs from the deep-cold temperature range or goes through repeated freezing and thawing, capsids rupture, aggregation occurs and titer falls. So temperature must be assured over the whole route from shipment to administration, and maintaining minus 60 °C or lower (or refrigeration) in a validated cold chain is essential. In fact, commercial AAV products are shipped frozen using dry ice or cryoshippers.

MakersELPRO, Sensitech

Why it is the standard. The US package inserts state conditions for each product. Luxturna is stored frozen at −65 °C or below (18 months from the date of manufacture under this condition). Zolgensma is shipped frozen, but after receipt it is used within 14 days under refrigeration (2–8 °C). In other words, it is not "frozen all the way"; where the product moves from frozen transport to refrigeration differs by product. Industry reviews (Cell & Gene, etc.) also recommend securing a sufficient dry ice supply for −80 °C viral vector transport, and cryoshippers (maintaining −150 °C or below for up to about 14 days) are used for long-distance, long-duration transport. Mechanistic studies have further shown that repeated freezing and thawing increases rupture, so temperature records over the entire route and avoidance of refreezing are the reference.

Alternatives in practice

  • LN2 dry vapor-phase cryoshipper · Chart/MVE dewar-type dry shipper (−150 °C class) — For ultra-deep-cold products and long-distance/international transport. Container cost is high and handling is strict
  • Validated transport at 2–8 °C under refrigeration · Pelican BioThermal/Sofrigam refrigerated passive shippers + loggers — Short distances for thawed or limited-quantity products. Not for frozen products

Step guide

What you actually do

  1. Place the frozen product in its primary container and secondary packaging and pack it into a validated shipping container together with dry ice or liquid nitrogen
  2. Include a temperature data logger, confirm it is operating before shipment and start the record
  3. Record the handover to the carrier and the route, and secure an arrangement for being notified of delays and temperature excursions
  4. On receipt, check the appearance of the container and the logger record and store the material at the specified temperature

Decision points

Dry ice packaging, or a liquid nitrogen vapor-phase dry shipper?
Dry ice (about −78.5 °C) is an option if the product's storage temperature is around minus 60 °C or below, and enough of it has to be secured for the transit time. A liquid nitrogen vapor-phase shipper holds −150 °C or below and suits long-distance or international shipping, but the container cost and handling constraints apply. Choose from the product's storage temperature and the transit time.
How far do you ship frozen, and from where do you move to refrigerated?
Conditions differ by item. As examples, Luxturna is stored frozen at −65 °C or below, while Zolgensma is shipped frozen and, after receipt, stored at 2 to 8 °C and used within 14 days. Decide an operation that avoids refreezing and a procedure for handling at the receiving site, matched to the conditions in the package insert.
What do you confirm in validating the shipping container?
Confirm by testing that the internal temperature stays within the specification under the expected transit time, ambient temperature, orientation and vibration conditions. The maker's validation data show the performance of the container; verification with your own shipping route and pack-out is carried out separately.
When a temperature excursion occurs, how do you decide on release for shipment?
Put the criteria for judging the logger record, in terms of how many minutes above what temperature, into the procedure beforehand. The criteria are decided from the product's stability data. Assessment of the excursion and whether the material may be used follow the approved procedures and the decision of the quality unit.

Common mistakes

  • Using the maker's hold time without verifying it with your own ambient temperatures and pack-out
  • Not considering dry ice replenishment, so that it sublimes away during a delay
  • Debating the criteria for judging a temperature excursion only after one has happened

Check at your own site

  • Has your own shipping been verified to hold temperature even for the transit time in the most delayed case?
  • Are your own temperature excursion criteria decided from the product's stability data and written into the procedure?

Characterization(13 steps)

Step 18: Vector genome titer (ddPCR)

ddPCR gives absolute vg quantitation, the denominator that is the starting point of all CQAs, deciding dose, empty/full ratio and lot uniformityddPCR gives absolute vg quantitation, the denominator that is the starting point of all CQAs, deciding dose, empty/full ratio and lot uniformity

Standard methodAbsolute quantitation by digital PCR (ddPCR)Absolute quantitation by digital PCR (ddPCR)
ReagentsddPCR Supermix (for probes)TaqMan probes (FAM/HEX-labeled)ITR/transgene-specific primersDNase IRestriction enzyme
Details and 3 alternatives

This step coversAbsolute quantitation of vector genome titer (vg/mL, GC/mL) (vector genome titer / ddPCR)

A step that accurately counts the amount of genome packaged in capsids (vg/mL) by digital PCR (ddPCR). It is the primary specification when the dose is set in vg/dose.

The value measured here is the "denominator" when the ratio to infectious titer (vg/IU) and the empty/full ratio are calculated. In other words, many quality indicators are built up from this number.

It is the basis that supports dose determination and dose uniformity between lots. It can be called the foundational quantitation that is the starting point of all critical quality attributes (CQAs).

This is the step that becomes the primary specification when the dose is set in vg/dose. The genome amount measured here is the denominator when the ratio to infectious titer (vg/IU) and the empty/full ratio are calculated, and it is the starting point of every CQA. It decides the dose, decides the numerator of the full:empty ratio (the amount of genome packaged), and also serves as the basis for whether the dose is uniform from lot to lot.

MakersBio-Rad, Applied Biosystems

Why it is the standard. It does not rely on a standard curve and counts even low-efficiency reactions as positive 1 molecule at a time. It therefore has a smaller CV than qPCR (generally under 10%), and values are easily consistent even across sites. Underestimation is also unlikely with scAAV, which has secondary structure, and it is regarded as the de facto reference method that can absolutely quantitate the AAV genome titer.

Alternatives in practice

  • Quantitative PCR (qPCR) · Applied Biosystems QuantStudio 7 Pro + TaqMan Fast Advanced Master Mix — Depends on a standard curve, so CV is larger than ddPCR. Widely available
  • Genome titer estimate from UV absorbance · Thermo NanoDrop One / spectrophotometer (A260/A280) — Simple, but cannot distinguish empty/full or free nucleic acids. For screening use
  • CDMS (charge detection MS) · Thermo Scientific Orbitrap (CDMS mode) / Megadalton Solutions — Directly evaluates the encapsidated genome by mass. Specialized and expensive instrument

Step guide

What you actually do

  1. Add DNase I to the sample to digest free DNA outside the capsids
  2. Open the capsids with proteinase K or similar to release the genomes inside, and dilute stepwise with diluent
  3. Mix with the reaction mix (Supermix, primers, probe), partition into droplets, amplify and count positives and negatives
  4. Obtain the copy number by Poisson statistics, apply the dilution factor back to give vg/mL, and judge the result together with that of the reference standard

Decision points

Is the target the ITR, the transgene, or both?
The ITR is common to every construct and can be measured with the same target even when the construct changes, but it has the weakness of being hard to amplify because it is a GC-rich hairpin. The transgene side amplifies stably but, depending on the position of the target, undercounts partial genomes. There are also configurations that measure both in the same well. A value aimed at the ITR and a value aimed at the transgene count different quantities, so do not compare them side by side.
How do you fix the order and conditions of DNase treatment and capsid digestion?
It is reported that the value moves greatly with the DNase treatment time, whether inactivation is needed, the temperature and time of capsid digestion, and whether dilution or heating comes first. There are cases where breaking the capsids with heat before dilution gave more than a 10-fold decrease. Write the figures out in full in the procedure and, when conditions are changed, set the before and after against each other.
ddPCR, or qPCR?
ddPCR needs no standard curve and is relatively robust to inhibitors, so its adoption for measuring genome titer is spreading. For qPCR too, there are reports that accuracy close to ddPCR was obtained by using a reference standard for the calibration curve and refining the sample preparation. Choose according to whether systematic bias or run-to-run variability weighs more heavily in your own process.
What do you use as the reference standard?
Public standards such as ATCC AAV2 and AAV8, or your own in-house standard, are used as the calibration reference point for the assay. Supply is limited, so settle how they are used and the procedure for switching lots (bridging old to new).

Common mistakes

  • Comparing figures with different targets and sample preparation side by side merely because the report says "measured by ddPCR"
  • Changing the order to heating before dilution, so that the value moves by an order of magnitude
  • Not bridging old to new when switching the standard lot, and losing continuity of the data

Check at your own site

  • Is your own genome titer measured under a procedure that fixes the target, the sample preparation and the reference standard?
  • When your own value and a contract laboratory's value diverge, what do you align and check first?

Step 19: Total capsid titer, full◇ Branches

A step that measures total particles and empty capsid fraction by SV-AUC and pins down the quality indicator vg/cp ratioSerotype-specific ELISA cannot recognize engineered capsids, so total particles are measured by antibody-independent methods

Standard methodSedimentation velocity analytical ultracentrifugation (SV-AUC)Antibody-independent methods such as mass photometry / SEC-MALS (ELISA is unsuitable for engineered capsids)
EquipmentAUCRefeyn mass photometers (TwoMP/SamuxMP), SEC-MALS (Wyatt DAWN), CDMS
ReagentsLabel-free (no labeling, UV absorbance detection)Analysis software (SEDFIT / UltraScan)
With Engineered capsidAntibody-independent methods such as mass photometry / SEC-MALS (ELISA is unsuitable for engineered capsids)With Natural serotypeSedimentation velocity analytical ultracentrifugation (SV-AUC)
Details and 4 alternatives

This step coversQuantitation of total capsid titer (cp/mL) and full:empty ratio (full = filled : empty = empty) (total capsid titer, full/empty ratio / SV-AUC)

A step that measures the "total number" of particles administered and the proportion of them that contain contents. Total capsid titer (cp/mL) and full:empty ratio are quantitated by sedimentation velocity analytical ultracentrifugation (SV-AUC).

Combining the two gives the vg/cp ratio (genome packaging efficiency), a figure showing how efficiently the genome could be packed.

The empty capsid fraction bears on immunogenicity, so these become critical quality attributes (CQAs) representing product quality. It is a step that pins down both quality and quantity of particles at the same time.

A step to pin down the total number of particles administered and the proportion of empty capsids, which bears on immunogenicity. Expressed in addition as the vg/cp ratio (the efficiency with which genomes were packaged), it becomes a critical quality attribute (CQA) that governs product quality.

MakersBeckman Coulter, Refeyn

Why it is the standard. It separates empty, partial, full and aggregated particles at once with high resolution and measures the amount of each. Moreover, measurement does not depend on labels or reference materials. With these features, it is widely accepted as the reference method for measuring the full:empty ratio.

Check also. Total capsid titer is complemented by combining capsid ELISA, mass photometry, SEC-MALS, AUC and others (there is no single absolute standard).

With Engineered capsid. Capsid ELISA (e.g., PROGEN) recognizes serotype-specific conformational epitopes, so reactivity drops or disappears with engineered capsids, leading to underestimation. Total particle counts are obtained by antibody-independent methods such as mass photometry (MP), SEC-MALS and charge detection mass spectrometry (CDMS).

Alternatives in practice

  • Total capsid ELISA · Progen AAV Titration ELISA (serotype-specific, sandwich format) + plate reader — Simple, high throughput. Possible underestimation due to dependence on conformational epitopes
  • Mass photometry · Refeyn SamuxMP Mass Photometer — Small sample volume and rapid, obtains empty/full/partially filled as a distribution. Complementary to AUC
  • AEX-HPLC · Thermo Scientific DNAPac/ProPac / Agilent 1290 Infinity II Bio LC + AEX column — Rapid quantitation of total capsid and full/empty ratio. Depends on resin conditions
  • UV A260/A280 ratio · Spectrophotometer (Thermo NanoDrop / Agilent Cary) — Simple estimate of full:empty. Limited to high-purity samples

Step guide

What you actually do

  1. Adjust the sample with formulation buffer, load it into the AUC cell, measure by SV-AUC and derive the proportions of empty, partial, full and aggregated species from the sedimentation coefficient distribution
  2. Measure the total capsid count separately by capsid ELISA, analytical AEX or mass spectrometry-based methods (mass photometry and the like)
  3. Divide the genome titer (vg/mL) by the total capsid count to calculate the vg/cp ratio (the efficiency of genome packaging)
  4. For each measurement, record the value of the reference standard, the method used and the analysis conditions

What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, the total particle count can be measured by a serotype-specific capsid ELISA. With engineered capsids, the epitope the ELISA recognizes changes, so reactivity drops or disappears and the count can be underestimated. Obtain the total particle count by antibody-independent methods such as mass photometry, SEC-MALS and CDMS)

Decision points

With what do you measure the total capsid count?
Capsid ELISA is simple and high-throughput, but it recognizes serotype-specific conformational epitopes, so it depends on antibody reactivity and can be thrown off by aggregation or the buffer. Antibody-independent methods such as SEC-MALS and CDMS are less affected by reactivity but place a greater burden on instrumentation. Choose after confirming that reactivity is retained for your serotype and formulation.
Do you use AUC for routine lot decisions?
AUC is strong as the yardstick (the reference method) against which figures from other methods are set, but its throughput is low and it requires sample volume and skill. A common split in practice is to run routine lot decisions on AEX-HPLC or a combination of ddPCR and ELISA, having set them against AUC once.
When the ratios disagree between methods, which one do you make the specification?
The empty/full ratio is defined differently by method, for instance in which side partially filled capsids are counted, and the values do not agree. State the measurement method in the specification and, when changing method, keep the data from measuring the same sample by both and setting them against each other.

Common mistakes

  • Obtaining the total particle count of an engineered capsid by ELISA and underestimating it without noticing the drop in reactivity
  • The AUC analysis conditions (boundary fitting, how peaks are delimited) differ between analysts, so decisions are not aligned
  • Judging the fill fraction from the ratio of ddPCR to ELISA alone, counting partially filled capsids on the filled side

Check at your own site

  • Does your own empty/full ratio specification state the measurement method and the analysis conditions as well?
  • Is there a plan to re-confirm reactivity for your own total capsid count when the serotype is changed or the capsid is engineered?

Step 20: Empty

Separates empty, partial and full by sedimentation coefficient difference and absolutely quantitates the CQA that governs titer, dose design and safetySeparates empty, partial and full by sedimentation coefficient difference and absolutely quantitates the CQA that governs titer, dose design and safety

Standard methodSedimentation velocity analytical ultracentrifugationSedimentation velocity analytical ultracentrifugation
ReagentsRotorSample sector buffer
Details and 4 alternatives

This step coversAbsolute quantitation and reference confirmation of the empty / full / partial capsid ratio (Empty/Full/Partial) (empty/full/partial capsid ratio / SV-AUC)

A step that divides capsids into 3 types, "empty, full and partial," and absolutely quantitates their ratio. It is measured by sedimentation velocity analytical ultracentrifugation and confirmed with a reference.

The proportion of full capsids that properly encapsulated the therapeutic genome directly governs quality. It decides titer, is the basis of dose design, and bears directly on safety.

That is why this ratio is a critical quality attribute (CQA) that regulators require to be shown in submissions without fail. It can be called the step that guarantees the contents of the product in numbers.

The proportion of full capsids that have properly encapsulated the therapeutic genome governs quality. It decides titer, is the basis of dose design, and bears directly on safety. That is why this proportion is a critical quality attribute (CQA) that regulators require to be shown in submissions without fail.

MakersBeckman Coulter, Refeyn

Why it is the standard. Capsids sediment differently (sedimentation coefficient) depending on the amount of contents. So empty (hollow, about 63S), partial (only partly filled) and full (about 93S) can be told apart by that difference, separated without labels, and even the amount of each measured accurately. It is also a method that the industry has long accepted as the reference method.

Alternatives in practice

  • Mass photometry (MP) · Refeyn SamuxMP (calibrated with empty AAV9, 3.74 MDa) — Empty/full/partially filled ratio from the molecular weight distribution. Small sample volume, rapid, highly correlated with AUC
  • AEX-HPLC/UPLC · Agilent 1290 Infinity II Bio LC + AEX column / Thermo DNAPac — Fast, highly reproducible full/empty separation. Calibration samples are needed
  • CDMS / native MS · Thermo Orbitrap (CDMS) / Megadalton Solutions — Directly judges empty/full by single-particle mass. Specialized instrument
  • UV spectroscopy A260/A280 · Spectrophotometer (Thermo NanoDrop) — Simple estimate of the full ratio. Accuracy is limited for mixtures

Step guide

What you actually do

  1. Load the sample with formulation buffer into the AUC sector, mount it in the rotor, centrifuge, and record the sedimentation boundary continuously with the absorbance or interference optics
  2. Obtain the sedimentation coefficient distribution c(s) with SEDFIT or similar and turn the peak areas for empty, partial, full and aggregated species into proportions
  3. Compare the results with orthogonal methods (analytical AEX, CDMS, TEM and the like) and confirm that the proportions are valid
  4. Fix the measurement conditions and the analysis parameters and record them together with the results

Decision points

When you place AUC as the reference method (the yardstick against which values from other methods are set), how do you hold down variability in the analysis?
Results move with cell preparation, the optics and the analysis parameters (boundary fitting, baseline, how peaks are delimited). Standardize the procedure, verify that decisions are aligned between analysts, and record the analysis conditions together with the figures.
What do you choose as orthogonal methods, and how do you set them against each other?
Analytical AEX is fast and suits routine lot control. CDMS resolves the gradation by mass, 1 particle at a time. TEM is used as a cross-check that confirms the state of separation in an image. Each technique handles partially filled capsids differently, so align the premises before comparing.
What do you confirm with the reference?
Measure known empty and full standards under the same conditions and confirm that the sedimentation coefficients or masses agree with the known values. As an example, there are reports that the empty species appears at about 63S and the full species at about 93S, but these move with serotype and conditions, so confirm them in your own system. Record the standard lot and the measurement history.
How do you handle the constraints on sample volume and concentration?
Because AUC detects the sedimentation boundary optically, it requires a concentration and a volume above a certain level. It is hard to apply to the dilute, small in-process samples, and the buffer's UV absorbance, density and viscosity also affect the measurement. Confirm the sample prerequisites first.

Common mistakes

  • Setting the AUC and AEX empty/full ratios side by side while ignoring the difference in how partially filled capsids are handled
  • Leaving the analysis parameters to the analyst, so that different proportions come out of the same raw data
  • Forcing AUC onto small, dilute in-process samples and losing precision

Check at your own site

  • Does your own reference method for the empty/full ratio fix the analysis conditions and verify reproducibility between analysts?
  • Do your own orthogonal methods include at least one technique based on a different principle?

Step 21: Genome integrity (CGE-LIF)

Full-length integrity of the encapsidated genome is evaluated by CGE-LIF, because truncated species cause poor expression and immune riskFull-length integrity of the encapsidated genome is evaluated by CGE-LIF, because truncated species cause poor expression and immune risk

Standard methodCapillary gel electrophoresis under denaturing conditions + laser-induced fluorescence detectionCapillary gel electrophoresis under denaturing conditions + laser-induced fluorescence detection
ReagentsBenzonase (nuclease)Proteinase KGuanidine hydrochloride (DNA purification)Intercalating fluorescent dyeSize standard (DNA ladder)AAV genome integrity assay kit
Details and 4 alternatives

This step coversEvaluation of genome integrity (whether the encapsidated genome is full length ITR-to-ITR as designed, and whether there are partial genomes / truncations / rearrangements) (genome integrity / CGE-LIF)

A step that confirms whether the encapsidated genome is "full length as designed." It examines whether it is continuous from ITR to ITR without breaks, and free of partial genomes, truncations and rearrangements.

Capillary gel electrophoresis under denaturing conditions and laser-induced fluorescence detection are used. Contamination with broken genomes is distinguished with high sensitivity.

Truncated species lead to poor transgene expression and the risk of immune response. That is why the full-length integrity of the genome is evaluated as a CQA that governs both titer and safety.

If the encapsidated genome is partial or broken partway, the transgene may not be expressed well. Such broken genomes (truncated species) also lead to the risk of triggering an immune response. That is why the full-length integrity of the genome is carefully evaluated as a critical quality attribute (CQA) that governs both titer and safety.

MakersBio-Rad, Merck, Agilent, SCIEX, Illumina

Why it is the standard. Compared with agarose gels and Southern blots, it has higher resolution and also excellent reproducibility. It can therefore accurately quantitate the ratio of full-length to partial genomes. Another reason for adoption is that it is widely used in the industry as a reference method for measuring AAV genome integrity.

Alternatives in practice

  • PacBio SMRT/HiFi long-read sequencing · PacBio Revio / Sequel IIe — Full length, ITR integrity and recombination at the single-molecule level. More detailed than CGE but higher cost
  • Duplex/milepost ddPCR · Bio-Rad QX600 Droplet Digital PCR — Detects truncation by the genome 5'/3' ratio. Sequence detail is not obtained
  • Alkaline denaturing agarose gel · Bio-Rad Sub-Cell + ChemiDoc — Simple confirmation of the encapsidated single-stranded genome. Resolution is inferior to CGE
  • Short-read NGS (Illumina) · Illumina NextSeq 2000/MiSeq — Sequence identification and detection of mutations/contamination. Weak for long-range structure

Step guide

What you actually do

  1. Treat the sample with nuclease to remove nucleic acids outside the capsids, break the capsids with proteinase K or similar, and purify the genomes
  2. Load into the capillary under denaturing conditions and detect an intercalating dye by laser-induced fluorescence (LIF)
  3. Compare with the size standard (DNA ladder) and obtain the peak area ratios of full-length genomes, partial genomes and truncated species
  4. Where needed, investigate the position of truncations and any recombination by long-read sequencing or duplex ddPCR

Decision points

Is CGE-LIF enough, or do you add long-read sequencing?
CGE-LIF has high resolution and reproducibility and suits quantifying the ratio of full-length to partial genomes. Long-read sequencing can see ITR integrity and recombination at the single-molecule level and is more detailed, but the cost and the analysis burden are greater. Think of the main quantitative method and the complementary method for confirming sequence detail separately.
How do you fix the sample preparation (removal of external nucleic acids, genome purification)?
If external nucleic acids remain they give false peaks, and if capsid digestion is insufficient the genomes do not come out. Confirm the nuclease treatment and capsid digestion conditions and the recovery of the purification first, and fix the procedure.
How do you use ddPCR and alkaline denaturing agarose gels for different purposes?
Duplex ddPCR looks at truncation from the ratio of the 5' side to the 3' side and does not give sequence detail. Alkaline denaturing agarose gels can be used for a simple check of single-stranded genomes, but their resolution is lower than CGE, so they suit screening.

Common mistakes

  • Removal of external nucleic acids is insufficient, so peaks that are not full length are overestimated
  • Substituting ddPCR aimed at one side only for the assessment of genome integrity, and missing partial genomes
  • The range of the size standard does not match the genome length of the construct, so sizes are assigned incorrectly

Check at your own site

  • Does your own assessment of integrity confirm the recovery of the sample preparation and the range of the size standard for each construct?
  • Are you tracking which upstream changes (plasmids, packaging) increase or decrease your own truncated species?

Step 22: VP1:VP2:VP3 ratio (CE-SDS)

CE-SDS measures the VP1:VP2:VP3 ratio, monitoring capsid assembly and transduction efficiencyCE-SDS measures the VP1:VP2:VP3 ratio, monitoring capsid assembly and transduction efficiency

Standard methodCE-SDS (sodium dodecyl sulfate capillary electrophoresis, UV absorbance detection)CE-SDS (sodium dodecyl sulfate capillary electrophoresis, UV absorbance detection)
ReagentsSDS-MW gel bufferSDSInternal standardReducing agent
Details and 4 alternatives

This step coversQuantitation of the capsid protein VP1:VP2:VP3 ratio (VP stoichiometry) (VP1:VP2:VP3 ratio / CE-SDS)

A step that measures the blend ratio of the three proteins that assemble the capsid, VP1:VP2:VP3. It is quantitated by CE-SDS (UV detection).

This ratio bears on whether the virus capsid assembles properly. It also affects the efficiency of infection and transduction (delivery of genes into cells).

That is why it is a critical quality attribute that serves as a yardstick for watching lot-to-lot variability and as an indicator of whether the manufacturing process is running stably.

The VP ratio is one of the critical quality attributes. It bears on whether the virus capsid assembles properly, and also affects the efficiency of infection and transduction. That is why it serves as a yardstick for watching lot-to-lot variability and as an indicator of whether the manufacturing process is running well.

MakersBio-Rad, Agilent, Waters, SCIEX, Progen

Why it is the standard. It is the successor method that evolved SDS-PAGE into high resolution with automated quantitation. %VP1:%VP2:%VP3 can be calculated reproducibly from the peak area of each VP band, and its advantage is that it is not easily affected by sample concentration. With these strengths, it is widely used as the industry standard for VP ratio measurement.

Alternatives in practice

  • Reversed-phase LC-UV / RP-UPLC · Agilent 1290 Infinity II Bio LC / Waters ACQUITY Premier + C4 column — Separation and ratio quantitation of intact VPs. Complementary to CE-SDS
  • SDS-PAGE densitometry · Bio-Rad Criterion/Mini-PROTEAN + ChemiDoc (Coomassie/silver stain) — Simple, low cost. Quantitative reproducibility is inferior to CE/LC
  • RP-LC-MS · Thermo Vanquish + Q Exactive/Orbitrap (intact VP mass + relative quantitation) — Obtains VP identification and ratio at the same time. Instruments and analysis are advanced
  • Western blot · Bio-Rad transfer + anti-VP (B1) and serotype-specific antibodies (Progen) — For identity confirmation. Quantitation is limited

Step guide

What you actually do

  1. Heat the sample under SDS and reducing conditions to separate the capsid into its individual VP proteins
  2. Inject into a capillary filled with SDS-MW gel buffer and apply voltage to separate by size
  3. Detect the peaks by UV (214 or 220 nm) and identify the VP1, VP2 and VP3 peaks against the internal standard
  4. Calculate %VP1, %VP2 and %VP3 from the peak areas and record them

Decision points

CE-SDS, SDS-PAGE, or reverse-phase LC / LC-MS?
CE-SDS quantifies automatically and can calculate the ratios reproducibly from the peak area of each VP. SDS-PAGE is simple and low-cost but less reproducible for quantitation. Reverse-phase LC and LC-MS also give the VP masses at the same time, but the instrument and analysis burden is greater.
How do you decide the reduction and heating conditions?
The type and concentration of the reducing agent and the temperature and time of heating affect peak separation and recovery. The ratios can move even with a small change, so fix the conditions and compare before and after when they are changed.
How do you set the specification for the VP ratio?
The VP ratio is regarded as a quality attribute related to how the capsid assembles and to the efficiency of infection and gene delivery. The expected ratio changes with serotype and production system, so do not carry over values from other companies or the literature; decide the range from the variability of your own development lots.

Common mistakes

  • Changing the heating or reduction conditions in the sample preparation and mistaking the resulting shift in the ratio for a lot-to-lot difference
  • The peak integration ranges differ between analysts, so the ratios are not aligned
  • Using the staining intensity of an SDS-PAGE gel directly as the ratio, overlooking the limits of its quantitative reproducibility

Check at your own site

  • Is your own range for the VP ratio decided from the variability of development lots?
  • Are the peak integration ranges for your own VP ratio fixed in the procedure?

Step 23: Capsid identification, PTM analysis (LC-MS)◇ Branches

LC-MS/MS characterizes, site by site, the identity of the serotype VP sequence and the PTMs that affect transduction efficiencyRather than identifying the serotype, the reference is to confirm the introduced modification (insertion/mutation) by sequence and mass

Standard methodLC-MS/MSLC-MS/MS peptide mapping + intact/subunit MS (confirming the sequence and mass of the modified site)
ReagentsC4/C18 column for RPHILIC columnDigestion enzyme (trypsin)Denaturing/reduction-alkylation reagents (DTT/IAA)Formic acid-containing mobile phase
With Engineered capsidLC-MS/MS peptide mapping + intact/subunit MS (confirming the sequence and mass of the modified site)With Natural serotypeLC-MS/MS
Details and 4 alternatives

This step coversIdentity of the capsid proteins (serotype confirmation) and characterization of post-translational modifications (PTMs) (capsid identification, PTM analysis / LC-MS)

A step that confirms whether the capsid protein (VP) is "the serotype as designed" and also examines its chemical modifications. LC-MS/MS is used.

First, identity: confirming that the VP sequence is that of the intended serotype. Next, post-translational modifications (PTMs): profiling where deamidation, oxidation, acetylation, phosphorylation and so on are present.

PTMs can affect the vector's transduction efficiency and infectious titer, so the step goes beyond confirming the sequence and characterizes what modifications are present.

Identity confirmation and PTM characterization of the capsid protein (VP) are needed for 2 reasons. The 1st is to confirm that the VP sequence is that of the serotype as designed. The 2nd is that post-translational modifications (PTMs) such as deamidation, oxidation, acetylation and phosphorylation can affect the vector's transduction efficiency and infectious titer. So the identity of the sequence is confirmed first, and then which PTMs are present, and where, is profiled.

MakersWaters, Promega, SCIEX, Progen

Why it is the standard. The procedure has 2 stages. First, intact mass confirms the VP sequence of each serotype and N-terminal processing (removal of the initiator methionine, N-terminal acetylation, acetylation of VP3, etc.). Peptide mapping then identifies and quantitates, site by site, more than 30 PTM sites (deamidation, oxidation, acetylation, phosphorylation) while covering nearly 100% of the sequence. Because it can pin down this much, it is positioned as the reference method for evaluating identity and PTMs.

With Engineered capsid. Serological identification of natural serotypes cannot be applied. For engineered capsids, LC-MS/MS peptide mapping directly confirms the sequence of the inserted peptide / mutation site, intact/subunit MS verifies the VP mass shift, and NGS of the cap gene verifies conformity to design as needed.

Alternatives in practice

  • RP-LC-MS of intact VPs · Waters ACQUITY Premier + BioAccord/Xevo (intact mass) — Rapid serotype identification and grasp of proteoforms. Sequence detail is complemented by MS/MS
  • Native mass spectrometry · Thermo Q Exactive UHMR / native MS configuration — Measures the mass of intact particles/VP complexes. Specialized instrument
  • Terminus and sequence confirmation by MS/MS · Thermo Orbitrap (bottom-up/middle-down) — N-/C-terminus and sequence confirmation. Multiple enzymes to maximize coverage
  • CGE-LIF / Western blot · SCIEX PA 800 Plus / Progen anti-VP and serotype-specific antibodies — Separation and simple identity confirmation of VP3-related species. Supplements mass spectrometry

Step guide

What you actually do

  1. Denature, reduce and alkylate the capsid and cut it into peptides with an enzyme such as trypsin
  2. Separate by reverse-phase LC and acquire MS/MS on a high-resolution mass spectrometer to identify the sequence and the sites of modification
  3. Measure the intact VPs by LC-MS and confirm the masses and the N-terminal modifications (acetylation and the like)
  4. Obtain the sequence coverage and the proportion of modification at each site and compare them with a reference lot

What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, the focus is on confirming identity against the known VP sequences. With engineered capsids, serological identification cannot be used, so confirm the sequence of the inserted peptide or mutation site directly by LC-MS/MS peptide mapping, look at the VP mass shift by intact or subunit MS, and verify conformity to design by NGS of the cap gene as needed)

Decision points

How do you combine intact mass and peptide mapping?
Intact mass confirms the VP masses for each serotype and the N-terminal processing (removal of the initiator methionine, acetylation). Peptide mapping covers the sequence broadly while identifying post-translational modifications (PTMs) site by site. This two-tier arrangement is commonly adopted as the way to investigate identity and PTMs.
One digestion enzyme, or several?
There is an approach of using several enzymes together to raise coverage. It can fill in regions that trypsin alone does not reach. Confirm the grade of the enzymes and the reproducibility of the digestion.
How do you reflect PTMs in the specification or in in-process monitoring?
PTMs such as deamidation and oxidation are said to be able to affect delivery efficiency and infectious titer, but which sites matter differs with serotype and function. Establish the range of the proportion at each site across development lots, confirm the relationship with the functional assay, and then decide whether to make them specification or in-process monitoring items.

Common mistakes

  • Mistaking oxidation and deamidation introduced during digestion for modifications of the capsid
  • Analyzing an engineered capsid against the known serotype sequence as the reference, and missing the insertion site
  • Taking the coverage of a single enzyme as comprehensive

Check at your own site

  • Is your own PTM range decided from the variability of development lots and its relationship with the functional assay?
  • Is matching against the sequence of a known serotype enough for the identity of your own capsid? Or do insertions and mutations have to be confirmed directly?

Step 24: Infectious titer and potency tests◇ Branches

A mandatory item that measures the ability to actually infect and express, and shows drug product quality and consistency through the vg/IU ratioTropism changes with the modification, so the cell model for potency is re-selected to match the target

Standard methodInfectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)Infectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)
With Engineered capsidTropism changes with the modification, so the cell model for potency is re-selected to match the targetWith Natural serotypeInfectious titer: TCID50 / qPCR/ddPCR endpoint method (genome copy measurement after infection)
Details and 4 alternatives

This step coversInfectious titer and potency (infectious titer / potency: the biological activity of infecting cells and expressing the transgene) (infectious titer and potency tests)

A regulatory-required step that measures the biological activity (infectious titer, potency) of "whether it actually infects cells and works."

The measurement uses TCID50 or qPCR/ddPCR endpoint methods. By measuring genome copies after infection, the titer of the particles that truly work is determined.

It also looks at the ratio of the number of infectious particles (IU) to the number of genome-containing particles (vg). This vg/IU ratio is an indicator of the quality and consistency of the drug product.

This is the item that confirms "whether it actually infects cells and works." It is also required by regulation. In addition, the ratio of how many truly infectious particles (IU) there are relative to the number of genome-containing viral particles (vg) is examined to show the quality and consistency of the drug product.

MakersBio-Rad, Molecular Devices, ATCC, BD, Applied Biosystems

Why it is the standard. A representative method for measuring infectious titer that reflects entry into cells and gene delivery. Values are made consistent by normalizing against an AAV2 reference standard or the like.

Check also. Potency in the regulatory sense is a separate concept. A cell-based expression/function assay based on the mechanism of action (MoA) of each product (transgene expression level, enzyme activity, change in cell function, etc.) must be set up separately. Infectious titer and potency are not combined under the same reference method.

With Engineered capsid. Engineered capsids differ from natural ones in receptors and tropism, so general-purpose infectious titer assays such as HEK293 can under- or overestimate. A cell-based potency (transgene expression / function) assay that reflects the target cell type and receptor is designed, and the infectious titer reference strain is also matched to the engineered capsid.

Alternatives in practice

  • ddPCR endpoint TCID50 · Bio-Rad QX600 ddPCR — Replaces qPCR with ddPCR for better sensitivity and precision. Makes the infectious titer absolute
  • Relative infectivity assay · Cell culture + qPCR/ddPCR (versus reference standard) — Lot-to-lot relative comparison. Consistency control rather than absolute titer
  • Cell-based expression potency · Reporter expression (luciferase/GFP) + plate reader/flow cytometry — Functional potency. Reflects the biological activity of the transgene
  • vg/IU ratio monitoring · ddPCR (vg) ÷ infectious titer (IU) — An indicator of infection efficiency. Trend control of manufacturing consistency

Step guide

What you actually do

  1. For infectious titer, plate the cells, add the sample in 10-fold serial dilutions, and culture with helper adenovirus
  2. After the specified time, lyse the cells and detect the amplified vector genomes by qPCR or ddPCR
  3. Obtain the 50% infectious endpoint from the distribution of positive wells and calculate the infectious titer (IU/mL)
  4. For potency, lay out the standard and the sample on the same plate and read the transgene product or a reporter to give the relative potency

What changes with the conditionWhether it is a natural serotype or an engineered capsid (with natural serotypes, general-purpose infectious titer assays based on HEK293 or HeLa lines and their reference strains can be used. Engineered capsids differ from natural ones in receptors and tropism, so a general-purpose system can under- or overestimate. Design a cell-based potency assay that reflects the target cell type and receptor, that is, one that reads transgene expression or function, and match the infectious titer reference strain to the engineered capsid as well)

Decision points

What do you use as the cell system for infectious titer?
There are reports that measuring other serotypes in an AAV2-oriented cell system such as RC32 opened up the vg/IU ratio greatly. AAV2 was close to 1, while AAV8 was on the order of several hundred. The denominator of the ratio carries the fit between serotype and assay within it. Choose a cell system that the serotype enters, from receptors and tropism, and confirm the selectivity of the system with negative controls.
How do you divide the roles of infectious titer and expression potency?
Infectious titer looks as far as the genome reaching the cell. Expression potency is a layer closer to the mechanism of action, is expressed as a value relative to the standard, and the parallelism of the dose-response curves is confirmed. The closer you get to the mechanism of action, the more the measurement wavers, so the specification range also widens.
How do you use an infectious titer graduated in 10-fold steps in a specification?
Because TCID50 is graduated in 10-fold serial dilutions, its resolution is 10-fold. Even a 2-fold difference between lots can come out as the same value. Rather than placing the infectious titer value itself at the center of the specification, it is more reliable to keep measuring with the same system, the same cell bank and the same standard and to look at process consistency from the movement of the ratio.
Do you assure potency by release testing alone?
The FDA draft of December 2023 asks that potency be built as an assurance strategy combining process design, process controls, control of raw materials, in-process testing and release testing, rather than relying on release testing alone. What the resolution of the assay cannot reach is filled in by process control.

Common mistakes

  • Setting another company's or the literature's vg/IU ratio beside your own value and arguing which is better, even though the systems differ
  • Replenishing the standard only after it has run out, so that separate work is needed to show continuity with the data up to then
  • Writing a 2-fold control range as the specification for a system graduated in 10-fold steps

Check at your own site

  • Does your own infectious titer system match the receptors and tropism of the serotypes and engineered capsids you handle?
  • How is your own potency apportioned across process control and control of raw materials, and not release testing alone?

Step 25: RcAAV detection

Because contamination with replication-competent AAV bears directly on patient safety, this is a safety test required by the FDA and othersBecause contamination with replication-competent AAV bears directly on patient safety, this is a safety test required by the FDA and others

Standard methodInoculate permissive cells (HeLa/HEK293 lines) with the sample in the presence of helper adenovirus, amplify by passaging, then detect by rep/cap-specific qPCRInoculate permissive cells (HeLa/HEK293 lines) with the sample in the presence of helper adenovirus, amplify by passaging, then detect by rep/cap-specific qPCR
EquipmentApplied Biosystems QuantStudio 7 Pro real-time PCR system (Thermo Fisher). CO2 incubator for passage culture (Thermo Heracell VIOS).
ReagentsTaqMan rep/cap-specific primers and probes, helper adenovirus, permissive cell lines (HeLa/HEK293 type), TaqMan Fast Advanced Master Mix (Thermo Fisher).
Details and 2 alternatives

This step coversDetection of replication-competent AAV (rcAAV): a safety test in which replication-competent AAV that may arise during manufacturing is amplified and passaged in permissive cells in the presence of helper adenovirus and detected by serotype-specific qPCR (rcAAV detection)

A safety test that looks for "AAV that multiplies by itself" (rcAAV), which can be born inadvertently during manufacturing. It can arise at low frequency by recombination between RepCap and ITRs.

The detection method brings it out by amplification. Permissive human cells are infected with rAAV and helper adenovirus and passaged multiple times, and whatever grows is watched.

Each passage is screened by serotype-specific qPCR to confirm that the level is below the detection limit. It is a step required by the FDA and is the linchpin of safety.

Replication-competent AAV can arise at low frequency through recombination between RepCap and ITRs, so FDA makes rcAAV testing mandatory for rAAV products. Permissive human cells are infected with rAAV and helper adenovirus and amplified through multiple passages, and each passage is screened by serotype-specific qPCR to confirm that the level is below the detection limit.

MakersBio-Rad, Thermo Fisher, Applied Biosystems

Why it is the standard. Cell amplification + serotype-specific qPCR is the industry standard method for amplifying and detecting low-frequency contamination with rcAAV with high sensitivity, and QuantStudio systems have an extensive GMP validation track record and are suited to specific quantitation of rep/cap sequences.

Alternatives in practice

  • Absolute rep/cap quantitation by ddPCR · Bio-Rad QX600 Droplet Digital PCR — Absolute quantitation of rep/cap sequences after amplification. Advantageous for detecting low-level rcAAV
  • Infectious titer-based rcAAV functional assay · Permissive cells + serial passage (cytopathic effect / titer measurement) — Evaluates replication competence functionally. Complementary to PCR; sensitivity and duration are issues

Step 26: Aggregate and particle size evaluation

SEC-MALS separates and quantitates monomers, dimers and aggregates, because aggregation bears directly on efficacy, immunity and safetySEC-MALS separates and quantitates monomers, dimers and aggregates, because aggregation bears directly on efficacy, immunity and safety

Standard methodSEC-MALS (size exclusion chromatography + multi-angle light scattering)SEC-MALS (size exclusion chromatography + multi-angle light scattering)
EquipmentMALS detector (multi-angle light scattering)Differential refractive index (dRI) detectorUV detectorHPLC (SEC column)FFF system (field flow fractionation)
Details and 3 alternatives

This step coversDetection and quantitation of aggregates (oligomers to large aggregates) and evaluation of particle size distribution (aggregate and particle size evaluation / SEC-MALS)

A step that evaluates the amount of "aggregates", in which particles have clumped together, and the particle size distribution. Aggregation bears directly on all of AAV's efficacy, the risk of provoking immunity, and safety.

SEC-MALS is used. The sample is first separated by size with size exclusion chromatography and then measured by multi-angle light scattering. Separating first and measuring afterward is the beauty of this method.

This allows monomer, dimer and large aggregates to be separated and quantitated individually. It is a step to accurately capture aggregation that threatens product quality.

Aggregation bears directly on all of AAV's efficacy, the risk of provoking immunity, and safety. That is exactly why accurate measurement is wanted, and what is used here is the MALS method, which measures after first separating by size. With this method, monomer, dimer and aggregates can each be separated and quantified.

MakersAgilent, Waters, Malvern Panalytical, Wyatt, Beckman Coulter

Why it is the standard. After separation, the absolute molecular weight and size of each peak can be determined directly by light scattering. Moreover, large aggregates that SEC (size exclusion chromatography) cannot fully separate can be separated without damage by FFF (flow FFF), which has low shear (the force that tears particles apart). For these reasons it is regarded as the de facto standard method for quantitating aggregates.

Check also. Combining FFF-MALS, AUC and DLS is effective for evaluating large aggregates.

Alternatives in practice

  • DLS / MADLS · Malvern Panalytical Zetasizer Ultra (MADLS) — Simple, obtains particle size distribution/aggregation from a small sample. No separation, so resolution of large aggregates is limited
  • SV-AUC · Beckman Coulter Optima AUC — Separates and quantitates aggregates by sedimentation coefficient. Low throughput and high analytical expertise required
  • Mass photometry · Refeyn SamuxMP — Directly observes dimers/aggregates by single-particle mass distribution. Small sample volume, rapid

Step guide

What you actually do

  1. Run the sample in an aqueous mobile phase at neutral pH and separate it by size on a SEC column
  2. Pass the eluate in turn through MALS (multi-angle light scattering), differential refractive index (dRI) and UV detectors
  3. Obtain the absolute molecular weight and particle size of each peak and give the proportions of monomer, dimer and aggregates
  4. Separate and measure large aggregates that SEC cannot resolve by field-flow fractionation (FFF)

Equipment and materials

Decision points

Is SEC-MALS enough, or do you add FFF?
In SEC, large aggregates can be retained on the column or broken by shear. Flow FFF applies little shear and is said to separate even large aggregates that SEC cannot resolve without damaging them. Decide according to the size range of the aggregation and whether a particle size distribution is needed.
How do you use DLS, SV-AUC and mass photometry for different purposes?
DLS is simple and needs little material, but because it does not separate, its resolution for large aggregates is limited. SV-AUC can separate and quantify aggregates too, but throughput is low. Mass photometry can see dimers and aggregates directly from the mass distribution of single particles and is quick with little material. Use SEC-based methods routinely and complement them with orthogonal methods for characterization.
How do you counter adsorption in the mobile phase and the flow path?
AAV readily adsorbs to surfaces at low concentration, and losses on the column and piping also feed through to apparent aggregation. Choose the mobile phase salt concentration, the additives and low-adsorption components by measuring recovery.

Common mistakes

  • Reading molecular weight from the SEC elution position and believing a value that is off because of a difference in shape
  • Mistaking particles that have dissociated on dilution in the mobile phase for the original state
  • Not confirming adsorption to the lines and the column from recovery, and overestimating how little aggregation there is

Check at your own site

  • Is your own assessment of aggregates configured so that sizes SEC cannot resolve are not missed?
  • Is the recovery of your own SEC-MALS confirmed for each sample?

Step 27: Particle number, subvisible particle control

SEC-MALS controls absolute particle number and light obscuration controls subvisible particles against USP limits at the same timeSEC-MALS controls absolute particle number and light obscuration controls subvisible particles against USP limits at the same time

Standard methodSEC-MALS (another method of estimating aggregates, molecular weight and particle number)SEC-MALS (another method of estimating aggregates, molecular weight and particle number)
EquipmentSEC-MALS (multi-angle light scattering detector)dRI (differential refractive index detector)UV detectorLiquid particle counter (subvisible)
ReagentsAqueous buffer mobile phaseStandard beads for particle size calibration
Details and 3 alternatives

This step coversSimultaneous measurement of particle number (physical titer = total capsid concentration) and particle size, and control of insoluble subvisible particles in the formulation (particle number, subvisible particle control)

A step that measures both the "number" and "size" of particles at the same time and also controls invisible particles. Physical titer (total capsid concentration) and particle size are measured by SEC-MALS.

Particle number (concentration) is the basis for deciding how much vector to administer. This measurement provides the yardstick for dose design.

In addition, for injectables, insoluble invisible particles (subvisible particles) must be kept within USP limits. It is a step that reconciles dose determination with particulate control.

Particle number (concentration) is the basis for deciding how much vector to administer. In addition, for injectables, the amount of invisible insoluble particles (subvisible particles) is required to be kept within USP limits. That is why the 2 are measured together.

MakersAgilent, Yokogawa, Malvern Panalytical, Wyatt, Beckman Coulter

Why it is the standard. SEC-MALS can directly derive the absolute number of particles from the ratio of eluted mass to molar mass. For subvisible particles, on the other hand, light obscuration is specified in USP <788> as the first-choice compendial method.

Check also. It is not an absolute standard for total capsid concentration. Results can deviate with sample purity, concentration, column recovery and serotype, so it is reported alongside and cross-checked with capsid ELISA, MP, NTA and AUC.

Alternatives in practice

  • NTA · Malvern Panalytical NanoSight Pro — Number and size distribution by nanoparticle tracking. Effective in the submicron range
  • Flow imaging microscopy (FIM) · Yokogawa FlowCam / Halo Labs HORIZON — Morphological identification of subvisible particles. Advantageous for distinguishing air bubbles from protein particles
  • Physical titer by DLS/MADLS · Malvern Zetasizer Ultra — Simple evaluation of particle size and concentration. SEC-MALS/particle counters are superior for absolute number

Step 28: Encapsulated impurity DNA quantitation

DNase-resistant encapsulated DNA is quantitated by qPCR; it cannot be degraded from the outside and is administered, so it is a safety CQADNase-resistant encapsulated DNA is quantitated by qPCR; it cannot be degraded from the outside and is administered, so it is a safety CQA

Standard methodQuantitation of encapsulated DNA by qPCR / ddPCR after DNase treatmentQuantitation of encapsulated DNA by qPCR / ddPCR after DNase treatment
ReagentsBenzonaseHost cell genomic DNA standardPrimers/probes for host repetitive sequence ampliconsPlasmid/helper-specific probes
Details and 3 alternatives

This step coversDetection and quantitation of encapsulated impurities (DNase-resistant contaminating DNA such as host cell DNA and plasmid/helper-derived DNA taken up inside the capsid) (encapsulated impurity DNA quantitation)

A step that measures "DNA taken up inside" the capsid. Encapsulated DNA cannot be degraded even by nuclease treatment from the outside.

The targets are host cell DNA and plasmid/helper-derived DNA. After DNase treatment, qPCR/ddPCR quantitates only the encapsulated DNA that survives.

Because this is administered to the patient as it is, it is a CQA governing safety. Free DNA below 10 ng per 1 dose and fragment length of roughly 200 bp or less are controlled as the guide.

DNA that has been taken up inside the capsid cannot be degraded from the outside even by nuclease treatment. It will be administered to the patient as it is, so it is treated as a critical quality attribute (CQA) that governs safety. That is why regulations also require its control. Specifically, free DNA not enclosed in the capsid is kept below 10 ng per 1 dose, and fragment length is also guided to be roughly 200 base pairs (bp) or less.

MakersBio-Rad, Merck, Illumina, PacBio, Applied Biosystems

Why it is the standard. Residual host cell DNA is an item whose control is required by ICH and the pharmacopoeias. qPCR is established as the standard method for quantitation. Moreover, by measuring the DNase-resistant fraction, only the portion encapsulated in the capsid can be captured separately.

Check also. DNase is a pretreatment, not a measurement method. Routine quantitation is qPCR/ddPCR after DNase treatment; characterization that looks at origin, fragment length and unknown contamination is NGS / long-read NGS. Residual host cell DNA is generally referenced at below 10 ng/dose and below about 200 bp, but for cell substrates of tumorigenicity concern such as HEK293/293T, stricter control may be required depending on product risk (the source is the FDA's "Characterization and Qualification of Cell Substrates and Other Biological Materials Used in the Production of Viral Vaccines for Infectious Disease Indications," February 2010, and WHO recommendations on cell substrates; this is not gene therapy CMC guidance).

Alternatives in practice

  • Absolute quantitation of encapsulated HCDNA by ddPCR · Bio-Rad QX600 ddPCR — No standard curve needed, quantitates low levels with high precision. Lower CV than qPCR
  • Encapsulated contaminating DNA by NGS · Illumina NextSeq 2000 (short-read) / PacBio Revio (long-read) — Covers the types and distribution of encapsulated nucleic acids comprehensively. PCR is better for quantitation
  • Commercial residual HCDNA quantitation kit · Thermo resDNASEQ HEK293 (qPCR) — Comes with standardization and regulatory documentation. Reduces design effort

Step guide

What you actually do

  1. Treat the sample with DNase (or Benzonase) to digest free DNA outside the capsids and inactivate the enzyme
  2. Break the capsids with proteinase K or similar and extract the nucleic acids left inside
  3. Run qPCR or ddPCR with primers and probes against the host repeat sequences (18S, Alu and the like) and against plasmid- and helper-derived sequences
  4. Convert to the quantity per dose from a standard (host genomic DNA) or by absolute quantitation

Decision points

How do you separate the control of encapsidated DNA from DNA outside the capsid (residual DNA)?
DNA on the outside can be removed by nuclease treatment and purification, so it can be controlled as a performance attribute of the process. DNA on the inside is settled at the moment the particle forms, so it can only be moved by upstream design. Unless a method for measuring outside and inside separately is established first, the cause cannot be identified when the value moves.
How do you set a reference point for the specification?
For free host DNA, the thinking presented by the FDA (2010) and the WHO for vaccine cell substrates, of 10 ng or less per dose with fragments of roughly 200 bp or less, is sometimes referred to. There is no agreed figure for applying this to DNA inside the capsid, and because AAV doses are orders of magnitude higher, it is discussed item by item. Follow what has been agreed with the authorities and the approved specification.
qPCR, ddPCR, or NGS?
qPCR is widespread as the standard method. ddPCR needs no standard curve, can quantify low amounts with high precision and is said to have a low CV. NGS can find unexpected sequences comprehensively, but PCR is better for quantitation. Combine them according to the purpose of the measurement (total quantity or breakdown).
How do you confirm the capsid digestion conditions and the recovery?
If the treatment is insufficient the DNA inside does not come out, and if it is excessive the DNA itself is broken. Confirm the recovery of the sample preparation with a spike-recovery test using a known amount of DNA.

Common mistakes

  • Watching only the total quantity and not tracking the breakdown (the origin, such as the resistance gene)
  • The capsid digestion conditions are insufficient, so the DNA inside does not come out and the amount is underestimated
  • Carrying another company's or the literature's specification values over to your own product without assessing the item's dose and risk

Check at your own site

  • Has your own encapsidated DNA a method established for measuring outside and inside separately?
  • Is your own residual DNA specification set in a form agreed with the authorities, taking the item's dose into account?

Step 29: Residual host-derived impurities: DNA/HCP

Quantitates residual host DNA, plasmid and HCP and keeps oncogenic and immune risk within FDA/WHO limitsQuantitates residual host DNA, plasmid and HCP and keeps oncogenic and immune risk within FDA/WHO limits

Standard methodResidual host cell DNAResidual host cell DNA
Details and 4 alternatives

This step coversResidual host-derived impurities (residual host cell DNA / residual plasmid and helper sequences / host cell protein HCP) (residual host-derived impurities: DNA/HCP)

A step that measures, all together, the "host-derived impurities left over" that purification could not fully remove, and shows conformance to specifications.

The targets are 3: residual host cell DNA, plasmid/helper sequences and host cell protein (HCP). All lead to risks of oncogenicity and immunogenicity.

That is why they are confirmed after being removed thoroughly. It is shown that FDA/WHO limits are met, such as free residual DNA below 10 ng per 1 dose and fragment length of roughly 200 bp or less.

Residual host-derived impurities are critical quality attributes that govern safety. Specifically, they are host cell DNA, plasmid- and helper-derived sequences, and host cell proteins (HCP). They lead to risks of oncogenicity and immunogenicity, so after careful removal, it is shown that the limits set by the FDA and WHO are met. For example, free residual DNA is kept below 10 nanograms per 1 dose, and fragment length at roughly 200 base pairs or less.

MakersBio-Rad, Bio-Techne, Molecular Devices, Cygnus Technologies, Techne

Why it is the standard. qPCR and ddPCR (18S/Alu), which are established methods, are used to quantitate residual DNA. Of these, ddPCR allows absolute quantitation and is superior in precision and CV. The Cygnus F650S 3G kit is used for HCP analysis. This is recognized in the industry as the reference method for analysis of HEK293-derived HCP and has obtained regulatory approval worldwide in multiple commercial cell products and gene therapies. The criteria for conformance follow the FDA/WHO limits (free residual DNA <10 ng/dose, fragments <~200 bp, etc.).

Check also. Residual host cell DNA is generally referenced at below 10 ng/dose and below about 200 bp, but for cell substrates of tumorigenicity concern such as HEK293/293T, stricter control may be required depending on product risk (the source is the FDA's "Characterization and Qualification of Cell Substrates and Other Biological Materials Used in the Production of Viral Vaccines for Infectious Disease Indications," February 2010, and WHO recommendations on cell substrates; this is not gene therapy CMC guidance).

Alternatives in practice

  • Fluorescent dye (PicoGreen-type) total DNA · Thermo Quant-iT PicoGreen + plate reader — Simple quantitation of total double-stranded DNA. Not sequence-specific, for screening
  • Mass spectrometry proteomics · Thermo Orbitrap (HCP identification/quantitation) — Identifies individual HCP species. Complements hard-to-detect HCPs that ELISA misses
  • Digital/qPCR for residual plasmid and adenovirus helper · Bio-Rad QX600 / QuantStudio — Individually quantitates plasmid/helper-derived sequences
  • Evaluation of replication-competent AAV · rep/cap qPCR/ddPCR + functional assay — Monitors rcAAV as well. Complements the safety profile

Step guide

What you actually do

  1. Extract DNA from the sample and quantify host sequences such as 18S and Alu by qPCR or ddPCR, with HEK293 genomic DNA as the standard
  2. Measure plasmid- and helper-derived sequences with separate primers and probes
  3. Measure the amount of host cell protein by an HCP ELISA for HEK293
  4. Measure the residual amount of enzymes added in the process, such as the nuclease, and record the results against the specification

Decision points

How do you confirm the coverage of the HCP ELISA?
Commercial HCP ELISA kits for HEK293 come with the maker's statement of antibody coverage, but confirmation with samples from your own process is needed separately. The HCP composition of the samples changes at each stage of the process, so one approach is to confirm the coverage by an orthogonal method such as mass spectrometry.
Do you identify individual HCP species by mass spectrometry?
Some HCPs are hard to see by ELISA, and identifying individual species by LC-MS complements it. Consider this when there is concern about whether a high-risk HCP remains.
With what do you measure residual DNA?
Both qPCR and ddPCR are used, and ddPCR, being absolute quantitation, is said to be the more precise. The recovery of the sample preparation (DNA extraction) moves the result, so include confirmation of recovery in the procedure.
How do you set the residual DNA specification?
For free residual DNA, the thinking presented by the FDA (2010) and the WHO for vaccine cell substrates, of 10 ng or less per dose with fragments of roughly 200 bp or less, is referred to. It is not a figure that applies to AAV as it stands. For AAV, the origin (host, plasmid, helper) is also at issue in addition to quantity and size. Follow the approved specification and what has been agreed with the authorities.

Common mistakes

  • Judging that HCPs have been sufficiently removed from the ELISA figure alone, without confirming coverage
  • Not looking at extraction recovery, and mistaking a value that moved because of a difference in sample preparation for a difference in the process
  • Dropping the item for measuring residual added enzymes such as the nuclease from the specification plan

Check at your own site

  • Has your own HCP ELISA had its coverage confirmed with your own process samples?
  • For your own impurity removal, is the contribution of each stage measured, so that you know which step removes what?

Step 30: Residual plasmid DNA quantitation

Encapsulated and free residual plasmids are manufacturing-derived genotoxic impurities that should be controlled separately from host DNAEncapsulated and free residual plasmids are manufacturing-derived genotoxic impurities that should be controlled separately from host DNA

Standard methodqPCR/ddPCR comparing with and without DNase treatment to distinguish plasmid encapsulated in capsids from free plasmid, targeting rep, cap, KanR and similar sequencesqPCR/ddPCR comparing with and without DNase treatment to distinguish plasmid encapsulated in capsids from free plasmid, targeting rep, cap, KanR and similar sequences
EquipmentBio-Rad QX600 Droplet Digital PCR System (comparison of ± DNase treatment distinguishes encapsulated from free plasmid).
Reagentsrep/cap/kanamycin resistance gene-specific primers and probes, Bio-Rad ddPCR Supermix for Probes, Merck Benzonase / DNase I (removal of free plasmid).
Details and 2 alternatives

This step coversQuantitation of residual plasmid DNA: residual plasmids from triple transfection (RepCap / AdHelper / kanamycin resistance gene, etc.) are quantitated by qPCR/ddPCR and controlled by a specification separate from host cell DNA (residual plasmid DNA quantitation)

A step that measures the "leftover plasmids" from triple transfection. A large amount of plasmid is put in with transient delivery, and its fragments can remain.

The targets are RepCap, AdHelper, kanamycin resistance gene and so on. Results with and without DNase treatment are compared to quantitate separately those encapsulated in capsids and those that are free.

These differ in origin from host cell DNA, so they are controlled as an independent specification. It is a quantitation targeting rep, cap, resistance genes and the like that is essential for safety and specifications.

In transient transfection a large amount of plasmid is put in, and its fragments can be encapsulated in the capsid or remain as free impurities, so quantitation of residual plasmid targeting rep/cap/antibiotic resistance genes and the like, independent of host cell DNA ([25]), is essential for safety and specifications.

MakersBio-Rad, Merck, Illumina, PacBio, Applied Biosystems

Why it is the standard. ddPCR can absolutely quantitate low-concentration residual plasmid sequences with high precision without depending on a standard curve, and combined with DNase treatment can separate encapsulated from free, so it is the working standard suited to specification control of manufacturing-derived DNA impurities.

Alternatives in practice

  • Real-time qPCR · Applied Biosystems QuantStudio 7 Pro + TaqMan Master Mix — Quantitates rep/cap/antibiotic resistance genes. CV is larger than ddPCR but widely available
  • Profiling of encapsulated nucleic acid impurities by NGS · Illumina NextSeq 2000 / PacBio Revio — Covers the sequence and distribution of encapsulated contaminating nucleic acids comprehensively. PCR is better for quantitation

Step guide

What you actually do

  1. Split the sample in two, treating one with DNase and leaving the other untreated
  2. Break the capsids, extract the nucleic acids, and run ddPCR or qPCR with primers and probes against targets such as rep, cap and the kanamycin resistance gene
  3. From the difference between treated and untreated, quantify plasmid encapsidated in capsids separately from free plasmid
  4. For each target, convert to the quantity per dose and record it against the specification

Equipment and materials

Decision points

Which sequences do you target?
Among the sequences in the backbones of RepCap, AdHelper and the transgene plasmid, choose mainly those that attract regulatory attention, such as the resistance gene. The nature of the risk differs by origin, so decide the number of targets and the sensitivity from risk assessment.
ddPCR, or qPCR?
ddPCR does not depend on a standard curve, can give absolute quantitation of low-concentration sequences with high precision, and suits comparing with and without DNase treatment to separate encapsidated from free material. qPCR is widespread but tends to have a larger CV than ddPCR.
Do you set the specification separately from host DNA?
Because the origin differs and the nature of the risk differs too, one approach is to control the specification independently of host DNA. How the specification is set follows what has been agreed with the authorities and the approved plan.
Do you add comprehensive confirmation by NGS?
Short-read and long-read sequencing can be used to investigate the types and distribution of encapsidated nucleic acids comprehensively. PCR is better for quantitation; sequencing is strong at finding unexpected sequences.

Common mistakes

  • Not comparing with and without DNase treatment, and judging on the total quantity without distinguishing encapsidated from free material
  • Not aligning the resistance gene quantitation method with the incoming testing stage for the raw plasmid, so that origin cannot be traced
  • Loose control of the assigned value of the standard plasmid, so that calibration drifts between lots

Check at your own site

  • Is your own residual plasmid set as a specification separate from host DNA?
  • Is your own resistance gene quantitation method aligned on the same target as the incoming test for the raw plasmid?

Guides that go deeper

The reference (“gold standard”) method is the one broadly recognized in published practice and guidelines; your process, product and regulator may justify another. Makers and products are examples, not endorsements. This map is translated from the Japanese edition, where it is updated first (Japanese version).